Postoperative Thrombus Formation in the False Lumen Following Surgical Repair of Aortic Dissection

1993 ◽  
Vol 27 (1) ◽  
pp. 27-32
Author(s):  
Isao Yada ◽  
Tomoaki Satoh ◽  
Kiyoto Wada ◽  
Tohoru Mizumoto ◽  
Takatugu Shimono ◽  
...  
Aorta ◽  
2016 ◽  
Vol 04 (01) ◽  
pp. 16-21 ◽  
Author(s):  
Conor Hynes ◽  
Michael Greenberg ◽  
Shawn Sarin ◽  
Gregory Trachiotis

AbstractStanford Type A aortic dissection is a rapidly progressing disease process that is often fatal without emergent surgical repair. A small proportion of Type A dissections go undiagnosed in the acute phase and are found upon delayed presentation of symptoms or incidentally. These chronic lesions may have a distinct natural history that may have a better prognosis and could potentially be managed differently then those presenting acutely. The method of repair depends on location and extent of the false lumen, as well as involvement of critical structures and branch arteries. Surgical repair techniques similar to those employed for acute dissection management are currently first-line therapy for chronic cases that involve the aortic valve, sinuses of Valsalva, coronary arteries, and supra-aortic branch arteries. In patients with high-risk for surgery, endovascular repairs have been successful, and active development of delivery systems and grafts will continue to enhance outcomes. We present two cases of chronic Type A aortic dissection and review the current literature.


2013 ◽  
Vol 62 (18) ◽  
pp. B163-B164
Author(s):  
Keith Thompson ◽  
Armen Chalian ◽  
Ryan Clare ◽  
Albert Yuh-Jer Shen ◽  
Steven Khan ◽  
...  

2016 ◽  
Vol 13 (124) ◽  
pp. 20160759 ◽  
Author(s):  
Claudia Menichini ◽  
Zhuo Cheng ◽  
Richard G. J. Gibbs ◽  
Xiao Yun Xu

Aortic dissection causes splitting of the aortic wall layers, allowing blood to enter a ‘false lumen’ (FL). For type B dissection, a significant predictor of patient outcomes is patency or thrombosis of the FL. Yet, no methods are currently available to assess the chances of FL thrombosis. In this study, we present a new computational model that is capable of predicting thrombus formation, growth and its effects on blood flow under physiological conditions. Predictions of thrombus formation and growth are based on fluid shear rate, residence time and platelet distribution, which are evaluated through convection–diffusion–reaction transport equations. The model is applied to a patient-specific type B dissection for which multiple follow-up scans are available. The predicted thrombus formation and growth patterns are in good qualitative agreement with clinical data, demonstrating the potential applicability of the model in predicting FL thrombosis for individual patients. Our results show that the extent and location of thrombosis are strongly influenced by aortic dissection geometry that may change over time. The high computational efficiency of our model makes it feasible for clinical applications. By predicting which aortic dissection patient is more likely to develop FL thrombosis, the model has great potential to be used as part of a clinical decision-making tool to assess the need for early endovascular intervention for individual dissection patients.


2017 ◽  
Author(s):  
Alireza Yazdani ◽  
He Li ◽  
Matthew R. Bersi ◽  
Paolo Di Achille ◽  
Joseph Insley ◽  
...  

AbstractAortic dissection is a pathology that manifests due to micro-structural defects in the aortic wall. Blood enters the damaged wall through an intimal tear, thereby creating a so-calledfalse lumenand exposing the blood to thrombogenic intramural constituents such as collagen. The natural history of this acute vascular injury thus depends, in part, on thrombus formation, maturation, and possible healing within the false lumen. A key question is: Why do some false lumens thrombose completely while other thrombose partially or little at all? An ability to predict the location and extent of thrombus in subjects with dissection could contribute significantly to clinical decision-making, including interventional design. We develop, for the first time, a data-drivenparticle-continuummodel for thrombus formation in a murine model of aortic dissection. In the proposed model, we simulate a final-value problem in lieu of the original initial-value problem with significantly fewer particles that may grow in size upon activation, representing the local concentration of blood-borne species. Numerical results confirm that geometry and local hemodynamics play significant roles in the acute progression of thrombus. Despite geometrical differences between murine and human dissections, mouse models can provide considerable insight and have gained in popularity owing to their reproducibility. Our results for three classes of geometrically different false lumens show that thrombus forms and extends to a greater extent in regions with lower bulk shear rates. Dense thrombi are less likely to form in high-shear zones and in the presence of strong vortices. The present data-driven study suggests that the proposed model is robust and can be employed to assess thrombus formation in human aortic dissections.


2015 ◽  
Vol 18 (5) ◽  
pp. 208
Author(s):  
Erhan Kaya ◽  
Hakan Fotbolcu ◽  
Zeki Şimşek ◽  
Ömer Işık

We report a 61-year-old patient who suffered from a type A aortic dissection that mimicked an acute inferior myocardial infarction. During a routine cardiac catheterization procedure, diagnostic catheters can be inserted accidentally into the false lumen. Invasive cardiologists should keep this complication in mind.


Sign in / Sign up

Export Citation Format

Share Document