Super-Selective Intra-Arterial Indocyanine Green Administration for Near-Infrared Fluorescence-Based Positive Staining of Hepatic Segmentation: A Feasibility Study

2021 ◽  
pp. 155335062199697
Author(s):  
Wei-Feng Li ◽  
Mahdi Al-Taher ◽  
Chun-Yen Yu ◽  
Yueh-Wei Liu ◽  
Yu-Yin Liu ◽  
...  

Background. Despite the increasing number of laparoscopic hepatic procedures for the resection of hepatocellular carcinoma (HCC), intraoperative tumor localization and demarcation remains challenging in comparison to open surgery. In this study, we evaluated the feasibility of positive liver segment staining through the super-selective intra-arterial indocyanine green (ICG) administration. Methods. Eight patients presenting with a single HCC underwent an interventional vascular procedure followed by laparoscopic surgery. A microcatheter was advanced into the hepatic artery branches perfusing the HCC followed by digital subtraction angiography and angiography computed tomography (angio-CT). Patients were then transferred to the operating room, and a laparoscopic hepatectomy was performed under ultrasound guidance. A 5 mL bolus of ICG with a concentration of .125 mg/mL was injected through the microcatheter, and a near-infrared laparoscope was used to detect the fluorescence signal to assess the correspondence between the fluorescence-based demarcation and the intraoperative ultrasound–based demarcation. Results. The duration for the angiography procedure was 32.7 +/− 5.3 min, and it took 242 +/− 118 min from the end of angiography procedure until the start of the surgical procedure. In all cases, the fluorescent liver segment was corresponding to the angio-CT findings. In 6/8 cases, fluorescence imaging was considered helpful in the identification of the resection line. In 3 patients, the resection line was changed according to the positively stained liver segment. Conclusion. We successfully demonstrated the feasibility of the super-selective intra-arterial ICG administration for fluorescence-based positive staining of hepatic segmentation during laparoscopic surgery for HCC (NCT04266548).

2012 ◽  
Vol 11 (2) ◽  
pp. 7290.2011.00031 ◽  
Author(s):  
Alicia Fernandez-Fernandez ◽  
Romila Manchanda ◽  
Tingjun Lei ◽  
Denny A. Carvajal ◽  
Yuan Tang ◽  
...  

Near-infrared (NIR) fluorophores are the focus of extensive research for combined molecular imaging and hyperthermia. In this study, we showed that the cyanine dye IR820 has optical and thermal generation properties similar to those of indocyanine green (ICG) but with improved in vitro and in vivo stability. The fluorescent emission of IR820 has a lower quantum yield than ICG but less dependence of the emission peak location on concentration. IR820 demonstrated degradation half-times approximately double those of ICG under all temperature and light conditions in aqueous solution. In hyperthermia applications, IR820 generated lower peak temperatures than ICG (4–9%) after 3-minute laser exposure. However, there was no significant difference in hyperthermia cytotoxicity, with both dyes causing significant cell growth inhibition at concentrations ≥ 5 μM. Fluorescent images of cells with 10 μM IR820 were similar to ICG images. In rats, IR820 resulted in a significantly more intense fluorescence signal and significantly higher organ dye content than for ICG 24 hours after intravenous dye administration ( p < .05). Our study shows that IR820 is a feasible agent in experimental models of imaging and hyperthermia and could be an alternative to ICG when greater stability, longer image collection times, or more predictable peak locations are desirable.


BJS Open ◽  
2021 ◽  
Vol 5 (2) ◽  
Author(s):  
M D Slooter ◽  
M S E Mansvelders ◽  
P R Bloemen ◽  
S S Gisbertz ◽  
W A Bemelman ◽  
...  

Abstract Background The aim of this systematic review was to identify all methods to quantify intraoperative fluorescence angiography (FA) of the gastrointestinal anastomosis, and to find potential thresholds to predict patient outcomes, including anastomotic leakage and necrosis. Methods This systematic review adhered to the PRISMA guidelines. A PubMed and Embase literature search was performed. Articles were included when FA with indocyanine green was performed to assess gastrointestinal perfusion in human or animals, and the fluorescence signal was analysed using quantitative parameters. A parameter was defined as quantitative when a diagnostic numeral threshold for patient outcomes could potentially be produced. Results Some 1317 articles were identified, of which 23 were included. Fourteen studies were done in patients and nine in animals. Eight studies applied FA during upper and 15 during lower gastrointestinal surgery. The quantitative parameters were divided into four categories: time to fluorescence (20 studies); contrast-to-background ratio (3); pixel intensity (2); and numeric classification score (2). The first category was subdivided into manually assessed time (7 studies) and software-derived fluorescence–time curves (13). Cut-off values were derived for manually assessed time (speed in gastric conduit wall) and derivatives of the fluorescence–time curves (Fmax, T1/2, TR and slope) to predict patient outcomes. Conclusion Time to fluorescence seems the most promising category for quantitation of FA. Future research might focus on fluorescence–time curves, as many different parameters can be derived and the fluorescence intensity can be bypassed. However, consensus on study set-up, calibration of fluorescence imaging systems, and validation of software programs is mandatory to allow future data comparison.


Sign in / Sign up

Export Citation Format

Share Document