scholarly journals Endovascular Coil Occlusion of Intracranial Aneurysms Assisted by a Novel Self-Expandable Nitinol Microstent (Neuroform)

2002 ◽  
Vol 8 (2) ◽  
pp. 107-119 ◽  
Author(s):  
H. Henkes ◽  
A. Bose ◽  
S. Felber ◽  
E. Miloslavski ◽  
E. Berg-Dammer ◽  
...  

Endovascular treatment of wide neck intracranial aneurysms is technically difficult and leads to less favorable treatment results and long term outcome. We participated in a multicenter prospective study to evaluate the safety and performance of a new self-expandable nitinol micro stent (Neuroform) in stent assisted coil occlusion of wide neck intracranial aneurysms. Eighteen patients were enrolled in the study in a single center. The anatomy of the target aneurysm and the parent vessel, technical details of the procedure, device functionality, anatomic and clinical results were evaluated. All enrolled aneurysms were either wide necked or showed an unfavorable neck-to-fundus ratio. In 16 out of 18 patients the Neuroform device allowed stent assisted coil occlusion of the aneurysm. The occlusion rate was 95% in eight patients and 100% in eight patients. The two failures were both due to anatomic reasons. Flexibility of the stent, behavior during deployment and subsequent ability to retain coils within the aneurysmal sac were considered as good as or better than the properties of previous balloon expandable stents. No device-related adverse events were encountered. Procedure-related clinical complications occurred in seven patients but caused no severe permanent neurological deficit. The Neuroform neurovascular stenting system is a safe and effective adjunct for the stent-assisted coil occlusion of wide necked intracranial aneurysms. The major advantages of this device are its self-expanding property and very high flexibility which allows safe navigation, easy sizing, as well as accurate positioning of the stent while providing sufficient bridging of the aneurysm neck for subsequent coil placement.

2015 ◽  
Vol 8 (11) ◽  
pp. 1186-1191 ◽  
Author(s):  
S Fischer ◽  
A Weber ◽  
A Titschert ◽  
C Brenke ◽  
A Kowoll ◽  
...  

PurposeTo retrospectively evaluate the safety and efficacy of the endovascular treatment of wide-necked intracranial aneurysms assisted by a novel intra-/extra-aneurysm stent-like implant (pCONus).MethodsInitial and follow-up angiographic and clinical results are presented of 25 patients with 25 unruptured and ruptured wide-necked intracranial aneurysms treated by reconstruction of the aneurysm neck using the pCONus implant followed by coil occlusion of the fundus.ResultsSuccessful intra-/extra-aneurysm deployment of the pCONus with coil occlusion of the fundus was achieved in all but one case. Procedure-related ischemic complications were observed in three cases with permanent deterioration in one. Acceptable aneurysm occlusion was achieved in all cases. Follow-up angiography revealed sufficient occlusion in 81.0% of the aneurysms. Intimal hyperplasia in the stented segment of the parent artery or device migration has not been observed to date.ConclusionsThe pCONus device offers a promising treatment option for complex wide-necked bifurcation intracranial aneurysms. Acute or delayed dislocations of coils into the parent artery are successfully avoided.


VASA ◽  
2002 ◽  
Vol 31 (1) ◽  
pp. 36-42 ◽  
Author(s):  
. Bucek ◽  
Hudak ◽  
Schnürer ◽  
Ahmadi ◽  
Wolfram ◽  
...  

Background: We investigated the long-term clinical results of percutaneous transluminal angioplasty (PTA) in patients with peripheral arterial occlusive disease (PAOD) and the influence of different parameters on the primary success rate, the rate of complications and the long-term outcome. Patients and methods: We reviewed clinical and hemodynamic follow-up data of 166 consecutive patients treated with PTA in 1987 in our department. Results: PTA improved the clinical situation in 79.4% of patients with iliac lesions and in 88.3% of patients with femoro-popliteal lesions. The clinical stage and ankle brachial index (ABI) post-interventional could be improved significantly (each P < 0,001), the same results were observed at the end of follow-up (each P < 0,001). Major complications occurred in 11 patients (6.6%). The rate of primary clinical long-term success for suprainguinal lesions was 55% and 38% after 5 and 10 years (femoro-popliteal 44% and 33%), respectively, the corresponding data for secondary clinical long-term success were 63% and 56% (60% and 55%). Older age (P = 0,017) and lower ABI pre-interventional (P = 0,019) significantly deteriorated primary clinical long-term success for suprainguinal lesions, while no factor could be identified influencing the outcome of femoro-popliteal lesions significantly. Conclusion: Besides an acceptable success rate with a low rate of severe complications, our results demonstrate favourable long-term clinical results of PTA in patients with PAOD.


2008 ◽  
Vol 108 (6) ◽  
pp. 1230-1240 ◽  
Author(s):  
Thomas R. Marotta ◽  
Thorsteinn Gunnarsson ◽  
Ian Penn ◽  
Donald R. Ricci ◽  
Ian Mcdougall ◽  
...  

Object The authors describe a novel device for the endovascular treatment of intracranial aneurysms, the endovascular clip system (eCLIPs). Descriptions of the device and its delivery system as well as the results of flow model tests and the treatment of experimental aneurysms are provided. Methods The eCLIPs comprises a flexible hybrid implantable device (an anchor and a covered leaf) and a balloon catheter delivery system, designed to be positioned and activated in the parent vessel in such a way that the covered portion will abut the aneurysm neck. The eCLIPs was subjected to testing in glass, elastomeric, and cadaveric flow models to determine its navigability, orientation, and activation compared with commercially available stents. In a second experiment, 8 carotid artery sidewall aneurysms in swine were treated using eCLIPs. The degree of occlusion was observed on angiography immediately following and 30 days after device activation, and a histological analysis was performed at 30 days. Results The device could navigate tortuous glass models and human cadaveric vessels. Compared with commercially available stents, the eCLIPs performed well. It could be navigated, oriented, and activated easily and reliably. With regard to the 8 porcine experimental aneurysms, immediate postactivation angiograms confirmed complete occlusion of 4 lesions and near occlusion of the other 4. Angiographic follow-up at 30 days postactivation showed occlusion of all 8 aneurysms and patency of all parent vessels. Histopathological analysis revealed aneurysm healing, with smooth-muscle cells growing across the lesion neck to allow reendothelialization. Conclusions Aneurysm occlusion with a single extrasaccular endovascular device has potential advantages. The authors believe that eCLIPs may prove to be a useful tool in the endovascular treatment of cerebral aneurysms. The system should reduce risks associated with coiling, procedure time, costs, and radiation exposure. The device satisfactorily occluded 8 experimental sidewall aneurysms. The observed healing pattern is similar to that seen after microsurgical clipping.


Stroke ◽  
2020 ◽  
Vol 51 (Suppl_1) ◽  
Author(s):  
Issei Kan ◽  
Toshihiro Ishibashi ◽  
Ichiro Yuki ◽  
Masayuki Ebara ◽  
Hideki Arakawa ◽  
...  

Objectives: Long term outcome of large / giant unruptured intracranial aneurysms (LG-UIAs) after endovascular therapy is still unknown. We retrospectively analyzed long-term results of patients with LG-UIAs who were followed up more than 5 years after endovascular therapy. Methods: We included patients from our complete database with UIAs greater than 10mm and treated at our hospital from January 2003 to December 2013. Retreatment rate of targeted aneurysms, rupture rate, and the modified Rankin scale (mRS) at last visit were evaluated till December 2018. Results: From 142 patients treated during the period were excluded 3 patients with perioperative rupture and 38 patients with less than 5 years follow-up period, finally analyzing 101 patients. The median aneurysm size was 12.0 mm (IQR 10.8-15). The median follow-up period was 9.4 years (IQR: 7-11), the longest being 13.3 years. Retreatment was performed on 36 patients (35.6%). Comparing cumulative re-treatment rates in groups with aneurysm sizes <15 mm and> 20 mm, it was predominantly higher for aneurysms> 20 mm (P = 0.02, Figure1 ). Rupture of targeted aneurysms was observed in 2 cases (1.98%, Figure2 ), and the longest period from last treatment was up to 12 years. The mRS 0-1 at the first treatment and the final visit were 98% and 93%, respectively, and mRS deterioration remained at 5%. Conclusion: The retreatment rate tended to increase in proportion to the size of the aneurysm, however the final neurological outcome was favorable when considering the natural history of these aneurysms. Since aneurysmal rupture could occur after 12 years of treatment, long-term follow-up should be considered for LG-UIAs.


2019 ◽  
Vol 30 (4) ◽  
pp. 817-826
Author(s):  
Fei Peng ◽  
Xin Feng ◽  
Xin Tong ◽  
Baorui Zhang ◽  
Luyao Wang ◽  
...  

Abstract Purpose To investigate the long-term clinical and angiographic outcomes and their related predictors in endovascular treatment (EVT) of small (<5 mm) ruptured intracranial aneurysms (SRA). Methods The study retrospectively reviewed patients with SRAs who underwent EVT between September 2011 and December 2016 in two Chinese stroke centers. Medical charts and telephone call follow-up were used to identify the overall unfavorable clinical outcomes (OUCO, modified Rankin score ≤2) and any recanalization or retreatment. The independent predictors of OUCO and recanalization were studied using univariate and multivariate analyses. Multivariate Cox proportional hazards models were used to identify the predictors of retreatment. Results In this study 272 SRAs were included with a median follow-up period of 5.0 years (interquartile range 3.5–6.5 years) and 231 patients with over 1171 aneurysm-years were contacted. Among these, OUCO, recanalization, and retreatment occurred in 20 (7.4%), 24 (12.8%), and 11 (7.1%) patients, respectively. Aneurysms accompanied by parent vessel stenosis (AAPVS), high Hunt-Hess grade, high Fisher grade, and intraoperative thrombogenesis in the parent artery (ITPA) were the independent predictors of OUCO. A wide neck was found to be a predictor of recanalization. The 11 retreatments included 1 case of surgical clipping, 6 cases of coiling, and 4 cases of stent-assisted coiling. A wide neck and AAPVS were the related predictors. Conclusion The present study demonstrated relatively favorable clinical and angiographic outcomes in EVT of SRAs in long-term follow-up of up to 5 years. THE AAPVS, as a morphological indicator of the parent artery for both OUCO and retreatment, needs further validation.


Neurosurgery ◽  
2009 ◽  
Vol 65 (5) ◽  
pp. E1007-E1008 ◽  
Author(s):  
Demetrius K. Lopes ◽  
Kalani Wells

Abstract OBJECTIVE To describe a novel stent remodeling technique for the coiling of ruptured wide-neck cerebral aneurysms. CLINICAL PRESENTATION A 46-year-old man presented with acute subarachnoid hemorrhage (Hunt and Hess grade IV), intracerebral hemorrhage, and hydrocephalus. Cerebral angiography revealed a wide-neck small anterior communicating artery aneurysm. Conventional coiling was not successful because of coil instability and compromise of the dominant anterior cerebral artery. TECHNIQUE A 6-French shuttle sheath (Cook Medical, Indianapolis, IN) was advanced from a right femoral approach into the right common carotid artery. To protect the parent vessel during coiling without compromising blood flow, a Prowler Select Plus catheter (Cordis Corporation, Bridgewater, NJ) was navigated across the aneurysm neck. Subsequently, an Enterprise stent (22-mm length; Cordis Corporation) was partially deployed across the aneurysm's wide neck. It was very important to watch the distal markers of the stent and lock the stent delivery wire to the Prowler Select Plus with a hemostatic valve once the stent was halfway deployed. This maneuver was essential to prevent further deployment of the stent. The SL-10 microcatheter and Synchro 14 wire (Boston Scientific, Natick, MA) were carefully navigated to the aneurysm passing through the partially deployed stent. Coils were then delivered to the aneurysm using the stent as a scaffold. After coiling, the SL-10 microcatheter was removed and the stent was recaptured into the Prowler Select Plus catheter. During the recapture, there was initial resistance. This was easily overcome after deploying the stent a little more before resheathing. During the procedure, the patient received 2000 U of heparin after the first coil was detached in the aneurysm. CONCLUSION The stent remodeling technique is a novel endovascular technique that can be used to treat ruptured wide-neck aneurysms and maintain patency of parent vessels, avoiding the use of antiplatelet therapy in acute subarachnoid hemorrhage.


2019 ◽  
Vol 17 (6) ◽  
pp. 562-572 ◽  
Author(s):  
Yoshihito Tsuji ◽  
Souvik Kar ◽  
Helmut Bertalanffy

Abstract BACKGROUND Due to the complex segmental organization of the brainstem, it is preferable to study midbrain cavernous malformations (MCMs) separately from pontine and medullary lesions. OBJECTIVE To evaluate clinical results after microsurgical removal of MCMs, assess predictors for outcome and introduce a topographical classification of MCMs. METHODS A retrospective study was conducted on consecutive patients who underwent MCM resection. Clinical parameters before and after surgery, morphological CM features, surgical approaches and outcomes were analyzed. MCMs were classified according to their exact location within the midbrain and their axial and sagittal extension. RESULTS The authors reviewed 72 patients (35 male). Lesions varied in size between 4 and 55 mm. The vast majority of patients benefited from surgery. The mean modified Rankin Scale (mRS) decreased significantly from 1.6 at admission to 1.3 at discharge and to 0.7 at follow-up (6-247 mo postoperatively). Five patients (6.9%) suffered from delayed hypertrophic olivary degeneration as visualized on magnetic resonance imaging. One male suffered from early postoperative re-bleeding that required surgical hematoma evacuation. There were no severe long tract impairment or other disabling complications, no delayed re-bleedings, and no surgical mortality. CONCLUSION We present a new topographic classification of MCMs that may be useful for predicting the occurrence of postoperative eye movement disorders. Other predictors of persistent oculomotor disturbances are time interval between onset of symptoms and surgery, and patient's age over 40 yr. Early surgery is recommendable in patients with oculomotor disturbances. MCM size over 18 mm, patient age over 40 yr, and poor mRS at admission are important predictors for the long-term outcome.


2005 ◽  
Vol 2 (1) ◽  
pp. 88-91 ◽  
Author(s):  
Nedal Hejazi

✓ The author performed a microsurgical infrapedicular paramedian approach in 35 patients (23 men and 12 women) to remove herniated lumbar retrovertebral discs that did not have an apparent origin at either the superior or inferior disc level. The goal of this surgery was to minimize the bone resection, preserve the facet joint, and avoid the risk of secondary vertebral instability. The Macnab outcome classification was used to assess all patients who attended follow-up examination for at least 15 months. The clinical results were excellent or good in 34 (97%) of 35 cases. This minimally invasive lumbar spine technique resulted in minimal morbidity, excellent clinical benefits, and a long-term outcome without evidence of secondary segmental instability.


1989 ◽  
Vol 71 (4) ◽  
pp. 512-519 ◽  
Author(s):  
Randall T. Higashida ◽  
Van V. Halbach ◽  
Leslie D. Cahan ◽  
Grant B. Hieshima ◽  
Yoshifumi Konishi

✓ Treatment of complex and surgically difficult intracranial aneurysms of the posterior circulation is now being performed with intravascular detachable balloon embolization techniques. The procedure is carried out under local anesthesia from a transfemoral arterial approach, which allows continuous neurological monitoring. Under fluoroscopic guidance, the balloon is propelled by blood flow through the intracranial circulation and, in most cases, can be guided directly into the aneurysm, thus preserving the parent vessel. If an aneurysm neck is not present, test occlusion of the parent vessel is performed and, if tolerated, the balloon is detached. Twenty-six aneurysms in 25 patients have been treated by this technique. The aneurysms have involved the distal vertebral artery (five cases), the mid-basilar artery (six cases), the distal basilar artery (11 cases), and the posterior cerebral artery (four cases). The aneurysms varied in size and included three small (< 12 mm), 15 large (12 to 25 mm), and eight giant (> 25 mm). Fifteen patients (60%) presented with hemorrhage and 10 patients (40%) with mass effect. In 17 cases (65%) direct balloon embolization of the aneurysm was achieved with preservation of the parent artery. In nine cases (35%), because of aneurysm location and size, occlusion of the parent vessel was performed. Complications from therapy included three cases of transient cerebral ischemia which resolved, three cases of stroke, and five deaths due to immediate or delayed aneurysm rupture. The follow-up period has ranged from 2 months to 43 months (mean 22.5 months). In cases where posterior circulation aneurysms have been difficult to treat by conventional neurosurgical techniques, intravascular detachable balloon embolization may offer an alternative therapeutic option.


2006 ◽  
Vol 12 (1) ◽  
pp. 31-35 ◽  
Author(s):  
K.F. Layton ◽  
H.J. Cloft ◽  
D.F. Kallmes

Perforation of intracranial aneurysms during endovascular treatment with platinum micro-coils is a well-known and serious complication reported to occur in 2–4% of patients. Inflation of a remodelling balloon across the aneurysm neck or within the proximal parent vessel is an additional technique that theoretically might be useful to reduce flow within the aneurysm and achieve hemostasis. In the case reports that follow, we present our experience using this technique for managing intraprocedural aneurysm rupture.


Sign in / Sign up

Export Citation Format

Share Document