A new visual feedback-based system for the assessment of pinch force, endurance, accuracy and precision. A test-retest reliability study

Hand Therapy ◽  
2021 ◽  
pp. 175899832110025
Author(s):  
Alberto Dottor ◽  
Eleonora Camerone ◽  
Mirko Job ◽  
Diletta Barbiani ◽  
Elisa Frisaldi ◽  
...  

Introduction Given that pinch is a precision grip involved in sustained submaximal activities, a Sustained Contraction (SC) task could be associated to Maximal Voluntary Contraction (MVC). To better evaluate the thumb-index system, the test-retest reliability of pinch MVC and SC, measured by a visual feedback-based pinch gauge was assessed. Methods 26 healthy participants performed MVC and SC in two separate sessions. SC required to maintain 40%MVC as long as possible and it was evaluated in terms of time, accuracy (Mean Distance between force trace and target force, MD), precision (Coefficient of Variability of force trace, CV). MD and CV analyses were conducted dividing the SC task into three equivalent time stages (beginning, middle, exhaustion). Relative Reliability (RR) was measured by Intraclass Correlation Coefficient, and Absolute Reliability (AR) was measured by Standard Error of Measurement and by Bland-Altman plot. Results MVC and Time showed high RR and AR in both hands. RR of MD and CV in right hand was excellent in the beginning and middle stages, and fair in the exhaustion one, showing decreasing reliability as fatigue increases. In the left hand RR of MD and CV was generally lower. MD showed excellent reliability in the beginning stage and good reliability in the other stages. CV showed fair relative reliability at both beginning and middle stages, excellent in the last one. Conversely, it was observed high AR of MD and CV in all stages in both hands. Conclusions All indices are reliable to assess motor control of thumb-index pinch in both hands.

Sports ◽  
2020 ◽  
Vol 8 (9) ◽  
pp. 117
Author(s):  
Mike Climstein ◽  
Jessica L. Alder ◽  
Alyce M. Brooker ◽  
Elissa J. Cartwright ◽  
Kevin Kemp-Smith ◽  
...  

Background: Usage of wrist-worn activity monitors has rapidly increased in recent years, and these devices are being used by both fitness enthusiasts and in clinical populations. We, therefore, assessed the test–retest reliability of the Polar Vantage M (PVM) watch when measuring heart rate (HR) during various treadmill exercise intensities. Methods: HR was measured every 30 s (simultaneous electrocardiography (ECG) and PVM). Test–retest reliability was determined using an intraclass correlation coefficient (ICC) with 95% confidence intervals (CIs). Standard error of measurement (SEM) and smallest real difference (SRD) were used to determine measurement variability. Results: A total of 29 participants completed the trials. ICC values for PVM during stages 1, 2 and 5 demonstrated good to excellent test–retest reliability (0.78, 0.78 and 0.92; 95% CI (0.54–0.90, 0.54–0.9, 0.79–0.97)). For PVM during stages 0 (rest), 3 and 4, the ICC values indicated poor to good reliability (0.42, 0.68 and 0.58; 95% CI (−0.27–0.73, 0.32–0.85, 0.14–0.80)). Conclusion: This study identified that the test–retest reliability of the PVM was comparable at low and high exercise intensities; however, it revealed a poor to good test–retest reliability at moderate intensities. The PVM should not be used in a clinical setting where monitoring of an accurate HR is crucial to the patients’ safety.


2013 ◽  
Vol 48 (3) ◽  
pp. 331-336 ◽  
Author(s):  
Rebecca Shultz ◽  
Scott C. Anderson ◽  
Gordon O. Matheson ◽  
Brandon Marcello ◽  
Thor Besier

Context: The Functional Movement Screen (FMS) is a popular test to evaluate the degree of painful, dysfunctional, and asymmetric movement patterns. Despite great interest in the FMS, test-retest reliability data have not been published. Objective: To assess the test-retest and interrater reliability of the FMS and to compare the scoring by 1 rater during a live session and the same session on video. Design: Cross-sectional study. Setting: Human performance laboratory in the sports medicine center. Patients or Other Participants: A total of 21 female (age = 19.6 ± 1.5 years, height = 1.7 ± 0.1 m, mass = 64.4 ± 5.1 kg) and 18 male (age = 19.7 ± 1.0 years, height = 1.9 ± 0.1 m, mass = 80.1 ± 9.9 kg) National Collegiate Athletic Association Division IA varsity athletes volunteered. Intervention(s): Each athlete was tested and retested 1 week later by the same rater who also scored the athlete's first session from a video recording. Five other raters scored the video from the first session. Main Outcome Measure(s): The Krippendorff α (K α) was used to assess the interrater reliability, whereas intraclass correlation coefficients (ICCs) were used to assess the test-retest reliability and reliability of live-versus-video scoring. Results: Good reliability was found for the test-retest (ICC = 0.6), and excellent reliability was found for the live-versus-video sessions (ICC = 0.92). Poor reliability was found for the interrater reliability (K α = .38). Conclusions: The good test-retest and high live-versus-video session reliability show that the FMS is a usable tool within 1 rater. However, the low interrater K α values suggest that the FMS within the limits of generalization should not be used indiscriminately to detect deficiencies that place the athlete at greater risk for injury. The FMS interrater reliability may be improved with better training for the rater.


2021 ◽  
pp. 1-6
Author(s):  
Fei Tian ◽  
Yaqi Zhao ◽  
Jixin Li ◽  
Wenjin Wang ◽  
Danni Wu ◽  
...  

Context: Many methods used to evaluate knee proprioception have shortcomings that limit their use in clinical settings. Based on an inexpensive 3D camera, a new portable device was recently used to evaluate the joint position sense (JPS) of the knee joint. However, the test–retest reliability of the new method remains unclear. This study aimed to evaluate the test–retest reliability of the new device and a long-arm goniometer for assessing knee JPS, and to compare the variability of the 2 methods. Design: Prospective observational study of the test–retest reliability of knee JPS measurements. Methods: Twenty-one healthy adults were tested in 2 sessions with a 1-week interval. Three target knee flexion angles (30°, 45°, and 60°) were reproduced in each session. Target and reproduced angles were measured with both methods. Intraclass correlation coefficients, standard error of the measurement, and Bland–Altman plots were used to quantify test–retest reliability. Paired t tests were used to compare knee JPS (absolute error of the target-reproduced angle) between the methods. Results: The new device (good to excellent intraclass correlation coefficients .74–.80; standard error of the measurement 0.52°–0.61°) demonstrated better test–retest reliability than the goniometer (poor to fair intraclass correlation coefficients .23–.43; standard error of the measurement 0.89°–2.07°) and better test–retest agreement (respective mean differences for the 30°, 45°, and 60° knee angles: 0.11°, 0.13°, and 0.41° for the new system; 0.84°, 1.52°, and 1.18° for the goniometer). The measurements (absolute errors of the target-reproduced angles) with the goniometer were significantly greater than those with the new device (P < .05); the SDs of repeated measurements with the goniometer (1.50°–2.41°) were greater than with the new device (1.08°–1.38°). Conclusions: Given that the new device has good reliability and sufficient precision, it is the better alternative for evaluating knee JPS. Goniometers should be used with caution to assess knee JPS.


2020 ◽  
Vol 4 (3) ◽  
pp. 925-945
Author(s):  
Leonardo Tozzi ◽  
Scott L. Fleming ◽  
Zachary D. Taylor ◽  
Cooper D. Raterink ◽  
Leanne M. Williams

Countless studies have advanced our understanding of the human brain and its organization by using functional magnetic resonance imaging (fMRI) to derive network representations of human brain function. However, we do not know to what extent these “functional connectomes” are reliable over time. In a large public sample of healthy participants ( N = 833) scanned on two consecutive days, we assessed the test-retest reliability of fMRI functional connectivity and the consequences on reliability of three common sources of variation in analysis workflows: atlas choice, global signal regression, and thresholding. By adopting the intraclass correlation coefficient as a metric, we demonstrate that only a small portion of the functional connectome is characterized by good (6–8%) to excellent (0.08–0.14%) reliability. Connectivity between prefrontal, parietal, and temporal areas is especially reliable, but also average connectivity within known networks has good reliability. In general, while unreliable edges are weak, reliable edges are not necessarily strong. Methodologically, reliability of edges varies between atlases, global signal regression decreases reliability for networks and most edges (but increases it for some), and thresholding based on connection strength reduces reliability. Focusing on the reliable portion of the connectome could help quantify brain trait-like features and investigate individual differences using functional neuroimaging.


Sexual Abuse ◽  
2020 ◽  
pp. 107906322090435
Author(s):  
Robin Welsch ◽  
Alexander F. Schmidt ◽  
Daniel Turner ◽  
Martin Rettenberger

The Explicit and Implicit Sexual Interest Profile (EISIP) is a multimethod measure of sexual interest in children and adults. It combines indirect latency-based measures such as the Implicit Association Test (IAT), Viewing Time (VT), and explicit self-report measures. This study examined test–retest reliability and absolute temporal agreement of the EISIP over a 2-week interval in persons who were convicted of sexual offenses against children ( n = 33) and nonoffending controls ( n = 48). Test–retest reliability of the aggregated EISIP measures was high across the whole sample ( rtt = .90, intraclass correlation coefficient [ICC] = .90) with the IAT yielding the lowest retest correlations ( rtt = .66, ICC = .66). However, these indicators of relative reliability only quantify the temporal stability of individual differences within the group, not the detectability of individual change. Absolute temporal agreement as assessed via Bland–Altman plots ranged from one fourth to three thirds of a standardized unit in the sexual preference scores. This implies that individual change has to exceed medium to large standardized effect sizes to be distinguishable from spontaneous temporal variation in the EISIP measures. Overall, scores of combined measures were largely superior to single measures in terms of both absolute and relative reliability.


BMC Neurology ◽  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Galina Stoyanova-Piroth ◽  
Ivan Milanov ◽  
Katerina Stambolieva

Abstract Background The purpose of the present study was to translate and cross-culturally adapt the King’s Parkinson’s Disease Pain Scale (KPPS) into Bulgarian and to investigate its psychometric properties in order to provide a validated Parkinson’s disease-specific pain instrument in Bulgarian language (KPPS-BG). Methods Translation into Bulgarian and a cultural adaptation were performed to obtain KPPS-BG. A total of 162 patients with idiopathic Parkinson’s disease were screened for pain using the complementary to the KPPS questionnaire – King’s Parkinson’s Disease Pain Questionnaire (KPPQ). KPPS-BG domain and total scores were calculated and internal consistency, construct validity and test-retest reliability were examined for 129 patients having one or more positive items in the KPPQ-BG. Results 79.6 % of the patients reported one or more types of pain. The most common type was musculoskeletal pain (83.7 %), followed by nocturnal pain (55.0 %), fluctuation-related pain (50.1 %), radicular pain (43.4 %), chronic pain (31.0 %), discoloration, edema/swelling (27.1 %) and, oro-facial pain (14.3 %). Mean KPPS-BG total score was 21.1 ± 17.3 SD. KPPS-BG showed a good reliability (Cronbach’s alpha 0.75). The test-retest reliability of the KPPS-BG was high and the intraclass correlation coefficient was 0.92, demonstrating а good repeatability. KPPS-BG total score was higher in patients with postural instability gait difficulty motor subtype, compared to tremor-dominant or indeterminate subtype. Significant positive correlations were found between KPPS-BG total score and modified H&Y, Movement Disorders Society Unified Parkinson’s Disease Rating Scale part III. Conclusions The KPPS-BG constitutes a reliable, comprehensive and useful tool for pain assessment in native Bulgarian patients with Parkinson’s disease.


Author(s):  
Michael J. Duncan ◽  
Darren Richardson ◽  
Rhys Morris ◽  
Emma Eyre ◽  
Neil D. Clarke

The present study examined the test–retest reliability of the Ghent University dribbling test and short dribble test in a pediatric population. Fifty-four boys aged 9–14 years (mean ± SD = 11 ± 2 years) undertook the Ghent University and dribbling tests on two occasions separated by 2 weeks. Intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement were conducted for each test. Intraclass correlation coefficients and coefficient of variation indicated good to excellent reliability, and relatively small variability for both dribbling tests. The 95% limits of agreement indicated relatively little bias Ghent University dribbling test for both running alone and running with the ball components, and the Bangsbo and Mohr short dribble test. The results of the present study suggest both dribbling tests examined in the present study demonstrate good reliability and low levels of systematic bias.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3075
Author(s):  
Nawale Hadouiri ◽  
Elisabeth Monnet ◽  
Arnaud Gouelle ◽  
Pierre Decavel ◽  
Yoshimasa Sagawa

Background: Walking disorders represent the most disabling condition in persons with Multiple Sclerosis (PwMS). Several studies showed good reliability of the 6-min walk test (6MWT) (i.e., especially distance traveled), but little is known about the reliability of the Spatio-temporal (ST) variables in the 6MWT. Objective: To evaluate the test-retest reliability of ST variables and perceived exertion during the 6MWT in PwMS and comparable healthy persons. Methods: We explored three 1-min intervals (initial: 0′–1′, middle: 2′30″–3′30″, end: 5′–6′) of the 6MWT. Six ST variables and perceived exertion were measured (respectively, using the GAITRite system and the Borg Scale). These measurements were performed twice, 1 week apart. The test-retest effects were assessed using the intraclass correlation coefficient (ICC) or the weighted kappa. Results: Forty-five PwMS and 24 healthy persons were included. The test-retest reliability of ST variables values was good-to-excellent for PwMS (ICC range: 0.858–0.919) and moderate-to-excellent for healthy persons (ICC range: 0.569–0.946). The test-retest reliability values of perceived exertion were fair for PwMS (weighted kappa range: 0.279–0.376) and substantial for healthy persons (weighted kappa range: 0.734–0.788). Conclusion: The measurement of ST variables during these 6MWT intervals is reliable and applicable in clinical practice and research to adapt rehabilitation care in PwMS.


2021 ◽  
Author(s):  
Galina Stoyanova-Piroth ◽  
Ivan Milanov ◽  
Katerina Stambolieva

Abstract Introduction:The purpose of the present study was to translate and cross-culturally adapt the King's Parkinson's Disease Pain Scale (KPPS) into Bulgarian and to investigate its psychometric properties in order to provide a validated Parkinson’s disease-specific pain instrument in Bulgarian language (KPPS-BG).Methods:Translation into Bulgarian and a cultural adaptation were performed to obtain KPPS-BG. A total of 162 patients with idiopathic Parkinson’s disease were screened for pain using the complementary to the KPPS questionnaire-King’s Parkinson's Disease Pain Questionnaire (KPPQ). KPPS-BG domain and total scores were calculated and internal consistency, construct validity and test-retest reliability were examined for 129 patients having one or more positive items in the KPPQ-BG.Results:79.6% of the patients reported one or more types of pain. The most common type was musculoskeletal pain (83.7%), followed by nocturnal pain (55.0%), fluctuation-related pain (50.1%), radicular pain (43.4%), chronic pain (31.0%), discoloration, edema/swelling (27.1%) and, oro-facial pain (14.3%). Mean KPPS-BG total score was 21.1±17.3 SD. KPPS-BG showed a good reliability (Cronbach's alpha 0.75). The test-retest reliability of the KPPS-BG was high and the intraclass correlation coefficient was 0.92, demonstrating а good repeatability. KPPS-BG total score was higher in patients with postural instability gait difficulty motor subtype, compared to tremor-dominant or indeterminate subtype. Significant positive correlations were found between KPPS-BG total score and modified H&Y, Movement Disorders Society Unified Parkinson’s Disease Rating Scale part III.Conclusion:The KPPS-BG constitutes a reliable, comprehensive and useful tool for pain assessment in native Bulgarian patients with Parkinson’s disease.


Assessment ◽  
2017 ◽  
Vol 26 (3) ◽  
pp. 419-431 ◽  
Author(s):  
Kelsie T. Forbush ◽  
Lindsay A. Hilderbrand ◽  
Brittany K. Bohrer ◽  
Danielle A. N. Chapa

Approximately 10% to 30% of individuals with eating disorders (EDs) are male, yet because measures often have not been tested among male participants, it is unclear whether the psychometric properties of ED measures are equivalent between sexes. The purpose of this study was to compare the test–retest reliability of common ED measures in men versus women. Participants ( N = 227; 58.1% female) completed self-report measures of body dissatisfaction, restrained eating, disinhibited eating, bulimic symptoms, and desire-for-muscularity at baseline and 2-to-4 weeks later. Intraclass correlations were used to compute retest correlations. Spearman’s rho was used to compute retest correlations for skewed and kurtotic variables. We compared 95% confidence intervals for intraclass correlation coefficients to determine whether measures differed in reliability between sexes. Most ED measures had at least acceptable test–retest reliabilities. However, few measures of disinhibited and binge eating demonstrated good reliability in men. Results highlight the utility of several ED measures for assessing symptom change over time, and the need for additional research to identify and correct for sources of gender unreliability among ED self-report measures in men—particularly for assessing constructs that include binge-eating behavior.


Sign in / Sign up

Export Citation Format

Share Document