Test–Retest Reliability of Soccer Dribbling Tests in Children

Author(s):  
Michael J. Duncan ◽  
Darren Richardson ◽  
Rhys Morris ◽  
Emma Eyre ◽  
Neil D. Clarke

The present study examined the test–retest reliability of the Ghent University dribbling test and short dribble test in a pediatric population. Fifty-four boys aged 9–14 years (mean ± SD = 11 ± 2 years) undertook the Ghent University and dribbling tests on two occasions separated by 2 weeks. Intraclass correlation coefficients, coefficient of variation, and 95% limits of agreement were conducted for each test. Intraclass correlation coefficients and coefficient of variation indicated good to excellent reliability, and relatively small variability for both dribbling tests. The 95% limits of agreement indicated relatively little bias Ghent University dribbling test for both running alone and running with the ball components, and the Bangsbo and Mohr short dribble test. The results of the present study suggest both dribbling tests examined in the present study demonstrate good reliability and low levels of systematic bias.

2021 ◽  
pp. 1-6
Author(s):  
Fei Tian ◽  
Yaqi Zhao ◽  
Jixin Li ◽  
Wenjin Wang ◽  
Danni Wu ◽  
...  

Context: Many methods used to evaluate knee proprioception have shortcomings that limit their use in clinical settings. Based on an inexpensive 3D camera, a new portable device was recently used to evaluate the joint position sense (JPS) of the knee joint. However, the test–retest reliability of the new method remains unclear. This study aimed to evaluate the test–retest reliability of the new device and a long-arm goniometer for assessing knee JPS, and to compare the variability of the 2 methods. Design: Prospective observational study of the test–retest reliability of knee JPS measurements. Methods: Twenty-one healthy adults were tested in 2 sessions with a 1-week interval. Three target knee flexion angles (30°, 45°, and 60°) were reproduced in each session. Target and reproduced angles were measured with both methods. Intraclass correlation coefficients, standard error of the measurement, and Bland–Altman plots were used to quantify test–retest reliability. Paired t tests were used to compare knee JPS (absolute error of the target-reproduced angle) between the methods. Results: The new device (good to excellent intraclass correlation coefficients .74–.80; standard error of the measurement 0.52°–0.61°) demonstrated better test–retest reliability than the goniometer (poor to fair intraclass correlation coefficients .23–.43; standard error of the measurement 0.89°–2.07°) and better test–retest agreement (respective mean differences for the 30°, 45°, and 60° knee angles: 0.11°, 0.13°, and 0.41° for the new system; 0.84°, 1.52°, and 1.18° for the goniometer). The measurements (absolute errors of the target-reproduced angles) with the goniometer were significantly greater than those with the new device (P < .05); the SDs of repeated measurements with the goniometer (1.50°–2.41°) were greater than with the new device (1.08°–1.38°). Conclusions: Given that the new device has good reliability and sufficient precision, it is the better alternative for evaluating knee JPS. Goniometers should be used with caution to assess knee JPS.


Assessment ◽  
2017 ◽  
Vol 26 (3) ◽  
pp. 419-431 ◽  
Author(s):  
Kelsie T. Forbush ◽  
Lindsay A. Hilderbrand ◽  
Brittany K. Bohrer ◽  
Danielle A. N. Chapa

Approximately 10% to 30% of individuals with eating disorders (EDs) are male, yet because measures often have not been tested among male participants, it is unclear whether the psychometric properties of ED measures are equivalent between sexes. The purpose of this study was to compare the test–retest reliability of common ED measures in men versus women. Participants ( N = 227; 58.1% female) completed self-report measures of body dissatisfaction, restrained eating, disinhibited eating, bulimic symptoms, and desire-for-muscularity at baseline and 2-to-4 weeks later. Intraclass correlations were used to compute retest correlations. Spearman’s rho was used to compute retest correlations for skewed and kurtotic variables. We compared 95% confidence intervals for intraclass correlation coefficients to determine whether measures differed in reliability between sexes. Most ED measures had at least acceptable test–retest reliabilities. However, few measures of disinhibited and binge eating demonstrated good reliability in men. Results highlight the utility of several ED measures for assessing symptom change over time, and the need for additional research to identify and correct for sources of gender unreliability among ED self-report measures in men—particularly for assessing constructs that include binge-eating behavior.


2008 ◽  
Vol 22 (6) ◽  
pp. 737-744 ◽  
Author(s):  
I-Ping Hsueh ◽  
Miao-Ju Hsu ◽  
Ching-Fan Sheu ◽  
Su Lee ◽  
Ching-Lin Hsieh ◽  
...  

Objective. To provide empirical justification for selecting motor scales for stroke patients, the authors compared the psychometric properties (validity, responsiveness, test-retest reliability, and smallest real difference [SRD]) of the Fugl-Meyer Motor Scale (FM), the simplified FM (S-FM), the Stroke Rehabilitation Assessment of Movement instrument (STREAM), and the simplified STREAM (S-STREAM). Methods. For the validity and responsiveness study, 50 inpatients were assessed with the FM and the STREAM at admission and discharge to a rehabilitation department. The scores of the S-FM and the S-STREAM were retrieved from their corresponding scales. For the test-retest reliability study, a therapist administered both scales on a different sample of 60 chronic patients on 2 occasions. Results. Only the S-STREAM had no notable floor or ceiling effects at admission and discharge. The 4 motor scales had good concurrent validity (rho ≥ .91) and satisfactory predictive validity (rho = .72-.77). The scales showed responsiveness (effect size d ≥ 0.34; standardized response mean ≥ 0.95; P < .0001), with the S-STREAM most responsive. The test-retest agreements of the scales were excellent (intraclass correlation coefficients ≥ .96). The SRD of the 4 scales was 10% of their corresponding highest score, indicating acceptable level of measurement error. The upper extremity and the lower extremity subscales of the 4 showed similar results. Conclusions. The 4 motor scales showed acceptable levels of reliability, validity, and responsiveness in stroke patients. The S-STREAM is recommended because it is short, responsive to change, and able to discriminate patients with severe or mild stroke.


2020 ◽  
Vol 47 (4) ◽  
pp. 479-486
Author(s):  
Yuki Kondo ◽  
Kyota Bando ◽  
Yosuke Ariake ◽  
Wakana Katsuta ◽  
Kyoko Todoroki ◽  
...  

BACKGROUND: The reliability of the evaluation of the Balance Evaluation Systems Test (BESTest) and its two abbreviated versions are confirmed for balance characteristics and reliability. However, they are not utilized in cases of spinocerebellar ataxia (SCA). OBJECTIVE: We aimed to examine the test-retest reliability and minimal detectable change (MDC) of the BESTest and its abbreviated versions in persons with mild to moderate spinocerebellar ataxia. METHODS: The BESTest was performed in 20 persons with SCA at baseline and one month later. The scores of the abbreviated version of the BESTest were determined from the BESTest scores. The interclass correlation coefficient (1,1) was used as a measure of relative reliability. Furthermore, we calculated the MDC in the BESTest and its abbreviated versions. RESULTS: The intraclass correlation coefficients (1,1) and MDC at 95% confidence intervals were 0.92, 8.7(8.1%), 0.91, 4.1(14.5%), and 0.81, 5.2(21.6%) for the Balance, Mini-Balance, and Brief-Balance Evaluation Systems Tests, respectively. CONCLUSIONS: The BESTest and its abbreviated versions had high test-retest reliability. The MDC values of the BESTest could enable clinicians and researchers to interpret changes in the balance of patients with SCA more precisely.


2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
Taher I. Omari ◽  
Johanna Savilampi ◽  
Karmen Kokkinn ◽  
Mistyka Schar ◽  
Kristin Lamvik ◽  
...  

Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements.Methods. Five subjects swallowed10×10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing.Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showedsubstantialtoexcellentagreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged fromslighttoexcellentdepending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showedexcellenttest-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showedmoderatetosubstantialtest-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged fromslighttosubstantial(mean Interrater ICC 0.15–0.61).Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility.


2021 ◽  
pp. 1-4
Author(s):  
Jamon Couch ◽  
Marc Sayers ◽  
Tania Pizzari

Context: An imbalance between shoulder internal rotation (IR) and external rotation (ER) strength in athletes is proposed to increase the risk of sustaining a shoulder injury. Hand-held (HHD) and externally fixed dynamometry are reliable forms of assessing shoulder IR and ER strength. A new externally fixed device with an attachable fixed upper-limb mold (The ForceFrame) exists; however, its reliability in measuring shoulder strength is yet to be investigated. Objective: To determine the test–retest reliability of the ForceFrame, with and without the fixed upper-limb mold, in the assessment of shoulder IR and ER strength, as compared with HHD. Design: Test–retest reliability study. Setting: Laboratory, clinical. Participants: Twenty-two healthy and active individuals were recruited from the university community and a private physiotherapy practice. Main Outcome Measures: Maximal isometric shoulder IR and ER strength was measured using the ForceFrame and traditional HHD in neutral and at 90° shoulder abduction. Mean (SD) strength measures were calculated. Test–retest reliability was analyzed using intraclass correlation coefficients (3, 1). The SEM and minimal detectable change were calculated. Results: Good to excellent test–retest reliability was found for all shoulder strength tests across Hand-held dynamometry (HHD) and externally fixed dynamometry (EFD) are reliable forms (intraclass correlation coefficients [3, 1] = .854–.916). The minimal detectable changes ranged between 25.61 and 41.84 N across tests. Test–retest reliability was not affected by the dynamometer or testing position. Conclusions: The results from this study indicate that both the ForceFrame and HHD are suitable for measuring shoulder strength in clinical practice. The use of the fixed upper-limb mold with the ForceFrame does not improve reliability.


2020 ◽  
pp. 1-5
Author(s):  
Gemma N. Parry ◽  
Lee C. Herrington ◽  
Ian G. Horsley ◽  
Ian Gatt

Context: Maximal power describes the ability to immediately produce power with the maximal velocity at the point of release, impact, and/or take off—the greater an athlete’s ability to produce maximal power, the greater the improvement of athletic performance. In reference to boxing performance, regular consistent production of high muscular power during punching is considered an essential prerequisite. Despite the importance of upper limb power to athletic performance, presently, there is no gold standard test for upper limb force development performance. Objective: To investigate the test–retest reliability of the force plate–derived measures of countermovement push-up in elite boxers. Design: Test–retest design. Setting: High Performance Olympic Training Center. Participants: Eighteen elite Olympic boxers (age = 23 [3] y; height = 1.68 [0.39] m; body mass = 70.0 [17] kg). Intervention: Participants performed 5 repetitions of countermovement push-up trials on FD4000 Forcedeck dual force platforms on 2 separate test occasions 7 days apart. Main Outcome Measures: Peak force, mean force, flight time, rate of force development, impulse, and vertical stiffness of the bilateral and unilateral limbs from the force–time curve. Results: No significant differences between the 2 trial occasions for any of the derived bilateral or unilateral performance measures. Intraclass correlation coefficients indicated moderate to high reliability for performance parameters (intraclass correlation coefficients = .68–.98) and low coefficient of variation (3%–10%) apart from vertical stiffness (coefficient of variation = 16.5%–25%). Mean force demonstrated the greatest reliability (coefficient of variation = 3%). In contrast, no significant differences (P < .001) were noted between left and right limbs (P = .005–.791), or between orthodox or southpaw boxing styles (P = .19–.95). Conclusion: Force platform–derived kinetic bilateral and unilateral parameters of countermovement push-up are reliable measures of upper limb power performance in elite-level boxers; results suggest unilateral differences within the bilateral condition are not the norm for an elite boxing cohort.


2017 ◽  
Vol 52 (5) ◽  
pp. 439-445 ◽  
Author(s):  
Tyler J. Oberlander ◽  
Bernadette L. Olson ◽  
Lee Weidauer

Context:  The King-Devick (KD) test is a screening tool designed to assess cognitive visual impairments, namely saccadic rhythm, postconcussion. Test-retest reliability of the KD in a healthy adolescent population has not yet been established. Objective:  To investigate the overall test-retest reliability of the KD among a sample of healthy adolescents. Additionally, we sought to determine if sex and age influenced reliability. Design:  Cross-sectional study. Setting:  Secondary school. Patients or Other Participants:  Sixty-eight healthy adolescents, 41 boys (age = 15.4 ± 1.9 years) and 27 girls (age = 15.4 ± 1.9 years). Main Outcome Measure(s):  Participants completed the KD (version 1) at 3 testing sessions (days 1, 30, and 45) following standard instructions. We recorded total time to complete the reading of 3 cards for each participant during each testing session. Two-way random-effects intraclass correlation coefficients (ICCs) using single measurements repeated over time and repeatability coefficients were calculated. Linear mixed models were used to determine whether differences existed at each testing time and to examine whether changes that took place among visits were different by sex or age. Results:  Adolescents who completed the KD demonstrated acceptable reliability (ICC = 0.81; 95% confidence interval = 0.73, 0.87); however, the repeatability coefficient was large (±8.76 seconds). The sample demonstrated improvements between visits 1 and 2 (mean ± standard error = 4.3 ± 0.5 seconds, P &lt; .001) and between visits 2 and 3 (2.4 ± 0.5 seconds, P &lt; .001) for a total improvement of 6.9 seconds over 3 tests. No significant visit-by-sex or visit-by-age interactions were observed. Conclusions:  Despite the ICC being clinically acceptable, providers using the KD test for serial assessment of concussion in adolescents should be cautious in interpreting the results due to a large learning effect. Incorporating multiple measures can ensure accurate detection of sport concussion.


2014 ◽  
Vol 114 (1) ◽  
pp. 93-103 ◽  
Author(s):  
Tomas Larson ◽  
Eva Norén Selinus ◽  
Clara Hellner Gumpert ◽  
Thomas Nilsson ◽  
Nóra Kerekes ◽  
...  

The Autism-Tics, AD/HD, and other Comorbidities (A–TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A–TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A–TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's κ. A–TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A–TAC had intra- and inter-rater reliability intraclass correlation coefficients of ≥ .60. Cohen's κ indicated acceptable reliability. The current study provides statistical evidence that the A–TAC yields good test-retest reliability in a population-based cohort of children.


Sign in / Sign up

Export Citation Format

Share Document