Exhaled breath analysis by ion mobility spectrometry in children with asthma and cystic fibrosis

Author(s):  
Michiel Bannier ◽  
Kim Van De Kant ◽  
Jorg Baumbach ◽  
Quirijn Jobsis ◽  
Edward Dompeling
Author(s):  
L. Tamina Hagemann ◽  
Stefan Repp ◽  
Boris Mizaikoff

The reliable online analysis of volatile compounds in exhaled breath remains a challenge as a plethora of molecules occur in different concentration ranges (i.e. ppt to %), and need to be detected against an extremely complex background matrix. While this complexity is commonly addressed by hyphenating a specific analytical technique with appropriate preconcentration and/or preseparation strategies prior to detection, we herein propose the combination of three analytical tools based on truly orthogonal measurement principles as an alternative solution: field-asymmetric ion mobility spectrometry (FAIMS), Fourier-transform infrared (FTIR) spectroscopy-based sensors utilizing substrate-integrated hollow waveguides (iHWG), and luminescence sensing (LS). These three tools have been integrated into a single compact analytical platform suitable for online exhaled breath analysis. The analytical performance of this prototype system was tested via artificial breath samples containing nitrogen (N2), oxygen (O2), carbon dioxide (CO2) and acetone as a model volatile organic compound (VOC) commonly present and detected in breath. Functionality of the combined system was demonstrated by detecting these analytes in their respectively breath-relevant concentration range and mutually independent of each other generating orthogonal yet correlated analytical signals. Finally, adaptation of the system towards the analysis of real breath samples during future studies is discussed.


Sensors ◽  
2019 ◽  
Vol 19 (12) ◽  
pp. 2653
Author(s):  
L. Tamina Hagemann ◽  
Stefan Repp ◽  
Boris Mizaikoff

The reliable online analysis of volatile compounds in exhaled breath remains a challenge, as a plethora of molecules occur in different concentration ranges (i.e., ppt to %) and need to be detected against an extremely complex background matrix. Although this complexity is commonly addressed by hyphenating a specific analytical technique with appropriate preconcentration and/or preseparation strategies prior to detection, we herein propose the combination of three different detector types based on truly orthogonal measurement principles as an alternative solution: Field-asymmetric ion mobility spectrometry (FAIMS), Fourier-transform infrared (FTIR) spectroscopy-based sensors utilizing substrate-integrated hollow waveguides (iHWG), and luminescence sensing (LS). By carefully aligning the experimental needs and measurement protocols of all three methods, they were successfully integrated into a single compact analytical platform suitable for online measurements. The analytical performance of this prototype system was tested via artificial breath samples containing nitrogen (N2), oxygen (O2), carbon dioxide (CO2), and acetone as a model volatile organic compound (VOC) commonly present in breath. All three target analytes could be detected within their respectively breath-relevant concentration range, i.e., CO2 and O2 at 3-5 % and at ~19.6 %, respectively, while acetone could be detected with LOQs as low as 165-405 ppt. Orthogonality of the three methods operating in concert was clearly proven, which is essential to cover a possibly wide range of detectable analytes. Finally, the remaining challenges toward the implementation of the developed hybrid FAIMS-FTIR-LS system for exhaled breath analysis for metabolic studies in small animal intensive care units are discussed.


PLoS ONE ◽  
2014 ◽  
Vol 9 (12) ◽  
pp. e114555 ◽  
Author(s):  
Hiroshi Handa ◽  
Ayano Usuba ◽  
Sasidhar Maddula ◽  
Jörg Ingo Baumbach ◽  
Masamichi Mineshita ◽  
...  

Author(s):  
Thomas Gaisl ◽  
Lukas Bregy ◽  
Nina Stebler ◽  
Martin Gaugg ◽  
Tobias Bruderer ◽  
...  

Author(s):  
Renate Kos ◽  
Paul Brinkman ◽  
Anne H Neerincx ◽  
Tamara Paff ◽  
Marije G Gerritsen ◽  
...  

2018 ◽  
Vol 12 (3) ◽  
pp. 036013 ◽  
Author(s):  
Thomas Gaisl ◽  
Lukas Bregy ◽  
Nina Stebler ◽  
Martin T Gaugg ◽  
Tobias Bruderer ◽  
...  

2010 ◽  
Vol 108 (3) ◽  
pp. 697-704 ◽  
Author(s):  
Wolfgang Vautz ◽  
Jürgen Nolte ◽  
Albrecht Bufe ◽  
Jörg I. Baumbach ◽  
Marcus Peters

Exhaled breath can provide comprehensive information about the metabolic state of the subject. Breath analysis carried out during animal experiments promises to increase the information obtained from a particular experiment significantly. This feasibility study should demonstrate the potential of ion mobility spectrometry for animal breath analysis, even for mice. In the framework of the feasibility study, an ion mobility spectrometer coupled with a multicapillary column for rapid preseparation was used to analyze the breath of orotracheally intubated spontaneously breathing mice during anesthesia for the very first time. The sampling procedure was validated successfully. Furthermore, the breath of four mice (2 healthy control mice, 2 with allergic airway inflammation) was analyzed. Twelve peaks were identified directly by comparison with a database. Additional mass spectrometric analyses were carried out for validation and for identification of unknown signals. Significantly different patterns of metabolites were detected in healthy mice compared with asthmatic mice, thus demonstrating the feasibility of analyzing mouse breath with ion mobility spectrometry. However, further investigations including a higher animal number for validation and identification of unknown signals are needed. Nevertheless, the results of the study demonstrate that the method is capable of rapid analyses of the breath of mice, thus significantly increasing the information obtained from each particular animal experiment.


CHEST Journal ◽  
2017 ◽  
Vol 151 (5) ◽  
pp. A104
Author(s):  
T. Gaisl ◽  
L. Bregy ◽  
N. Stebler ◽  
M. Gaugg ◽  
T. Bruderer ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document