Diagnostic accuracy of TB PCR in mediastinal lymph node TB in a UK centre using EBUS-TBNA

Author(s):  
Mirae Park ◽  
Kartik Kumar ◽  
Sean O'Riordan ◽  
Meg Coleman ◽  
Laura Martin ◽  
...  
2020 ◽  
Vol 14 ◽  
pp. 175346662090703 ◽  
Author(s):  
Xin He ◽  
Yanjun Wu ◽  
Haoyan Wang ◽  
Ganggang Yu ◽  
Bo Xu ◽  
...  

Background: Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is a widely used, safe, and accurate technique for obtaining pathological specimens to be used in the diagnosis of diseases involving lung hilar and mediastinal lymph node (LN) enlargement. However, application of the suction technique during EBUS-TBNA remains controversial. In addition, the effectiveness of the slow-pull capillary technique for the diagnosis of pancreatic masses was recently reported. The aim of this study was to compare the diagnostic accuracy of EBUS-TBNA using these two techniques. Methods: The accuracy, sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and availability of tissue cores of the suction and slow-pull capillary techniques were studied retrospectively in patients who underwent EBUS-TBNA for the diagnosis of diseases involving lung hilar and mediastinal LN enlargement. Results: A total of 97 patients with hilar and mediastinal LN enlargement underwent EBUS-TBNA; 30 patients underwent the suction technique, 56 patients underwent the slow-pull capillary technique, 5 patients underwent both techniques, and 6 patients had failed operations. The accuracy, sensitivity, specificity, NPV, PPV, and the number of tissue cores obtained with the suction and slow-pull capillary techniques were 66.67% versus 85.71% ( p = 0.039), 43.75% versus 85.42% ( p < 0.001), 92.86% versus 87.5% ( p > 0.05), 59.09% versus 50% ( p > 0.05), 87.5% versus 97.62% ( p > 0.05), and 19 versus 50 ( p = 0.004), respectively. In both univariate and multivariate analyses, the acquisition of tissue core was significantly associated with the diagnostic accuracy of EBUS-TBNA. Moreover, the slow-pull capillary technique was significantly associated with the acquisition of tissue core in EBUS-TBNA. There were no significant differences between the two groups in the blood contamination of samples. Conclusions: Use of the slow-pull capillary technique in EBUS-TBNA can significantly increase the accuracy related to the diagnosis of diseases involving hilar and mediastinal LN enlargement by improving the acquisition of tissue core. The reviews of this paper are available via the supplemental material section.


2019 ◽  
Vol 89 (1) ◽  
Author(s):  
Sergio C. Conte ◽  
Giulia Spagnol ◽  
Marco Biolo ◽  
Marco Confalonieri

The conventional-trans bronchial needle aspiration (c-TBNA) has been the first procedure for sampling hilar/mediastinal lymph node for the diagnosis/staging of lung cancer. In the last decade the endobronchial ultrasound trans bronchial needle aspiration (EBUS-TBNA) was introduced in clinical practice and became the first-choice exam in diagnosis and staging of lung cancer. The aim of this study was to compare the diagnostic accuracy (DA), sensitivity and adequacy of c-TBNA and EBUS-TBNA. It was a retrospective and observational multicenter study. The first endpoint was diagnostic accuracy of EBUS-TBNA versus c-TBNA. The secondary end-points were sensitivity and adequacy. Two hundred and nine consecutive patients underwent the procedure, 99 EBUS-TBNA and 110 c-TBNA. When lymph nodes with short axis <2 cm the diagnostic accuracy for correct diagnosis was 94.2% in EBUS-TBNA group and 89.7% in c-TBNA group (p=0.01); the sample adequacy was 70.3% and 42%, respectively (p=0.01); the sensitivity was 93% (95% CI, 82-98%) and 86.4% (95% CI, 67.6-95.6%), respectively (p=0.002). In lymph nodes with short axis ≥2 cm the diagnostic accuracy was 95.7% in EBUS-TBNA group and 93% in c-TBNA group (p=0.939); the sample adequacy was 68.7% and 68.3%, respectively (p=0.889); the sensitivity was 95.1% (95% CI, 83-99%) and 92.1%, respectively (95% CI, 78.7-97.7%) (p=0.898). The EBUS-TBNA in patients with lymph nodes size <2 cm presented a statistically significant difference in the DA, adequacy and sensitivity compared to c-TBNA procedure, while there were no significant differences in the DA, adequacy and sensitivity between EBUS-TBNA and c-TBNA in patients with lymph node size ≥2 cm. The results of our study indicated that the EBUS-TBNA should be the first-choice procedure for the diagnosis/staging in lung cancer patients with lymph node size <2 cm. In patients with lymph node size ≥2 cm, instead, both procedures can be used for the diagnosis/staging of lung cancer.


Sign in / Sign up

Export Citation Format

Share Document