Ventilation Heterogeneity in Asthma and COPD. The value of the poorly communicating fraction, as the ratio of total lung capacity to alveolar volume

Author(s):  
Annalisa Frizzelli ◽  
Roberta Pisi ◽  
Marina Aiello ◽  
Luigino Calzetta ◽  
Laura Marchi ◽  
...  
Respiration ◽  
2021 ◽  
pp. 1-7
Author(s):  
Roberta Pisi ◽  
Marina Aiello ◽  
Luigino Calzetta ◽  
Annalisa Frizzelli ◽  
Veronica Alfieri ◽  
...  

<b><i>Background:</i></b> The ventilation heterogeneity (VH) is reliably assessed by the multiple-breath nitrogen washout (MBNW), which provides indices of conductive (<i>S</i><sub>cond</sub>) and acinar (<i>S</i><sub>acin</sub>) VH as well as the lung clearance index (LCI), an index of global VH. VH can be alternatively measured by the poorly communicating fraction (PCF), that is, the ratio of total lung capacity by body plethysmography to alveolar volume from the single-breath lung diffusing capacity measurement. <b><i>Objectives:</i></b> Our objective was to assess VH by PCF and MBNW in patients with asthma and with COPD and to compare PCF and MBNW parameters in both patient groups. <b><i>Method:</i></b> We studied 35 asthmatic patients and 45 patients with COPD. Each patient performed spirometry, body plethysmography, diffusing capacity, and MBNW test. <b><i>Results:</i></b> Compared to COPD patients, asthmatics showed a significantly lesser degree of airflow obstruction and lung hyperinflation. In asthmatic patients, both PCF and LCI and <i>S</i><sub>acin</sub> values were significantly lower than the corresponding ones of COPD patients. In addition, in both patient groups, PCF showed a positive correlation with LCI (<i>p</i> &#x3c; 0.05) and <i>S</i><sub>acin</sub> (<i>p</i> &#x3c; 0.05), but not with <i>S</i><sub>cond</sub>. Lastly, COPD patients with PCF &#x3e;30% were highly likely to have a value ≥2 of the mMRC dyspnea scale. <b><i>Conclusions:</i></b> These results showed that PCF, a readily measure derived from routine pulmonary function testing, can provide a comprehensive measure of both global and acinar VH in asthma and in COPD patients and can be considered as a comparable tool to the well-established MBNW technique.


2018 ◽  
Vol 52 (5) ◽  
pp. 1800821 ◽  
Author(s):  
Laurie J. Smith ◽  
Guilhem J. Collier ◽  
Helen Marshall ◽  
Paul J.C. Hughes ◽  
Alberto M. Biancardi ◽  
...  

Hyperpolarised helium-3 (3He) ventilation magnetic resonance imaging (MRI) and multiple-breath washout (MBW) are sensitive methods for detecting lung disease in cystic fibrosis (CF). We aimed to explore their relationship across a broad range of CF disease severity and patient age, as well as assess the effect of inhaled lung volume on ventilation distribution.32 children and adults with CF underwent MBW and 3He-MRI at a lung volume of end-inspiratory tidal volume (EIVT). In addition, 28 patients performed 3He-MRI at total lung capacity. 3He-MRI scans were quantitatively analysed for ventilation defect percentage (VDP), ventilation heterogeneity index (VHI) and the number and size of individual contiguous ventilation defects. From MBW, the lung clearance index, convection-dependent ventilation heterogeneity (Scond) and convection–diffusion-dependent ventilation heterogeneity (Sacin) were calculated.VDP and VHI at EIVT strongly correlated with lung clearance index (r=0.89 and r=0.88, respectively), Sacin (r=0.84 and r=0.82, respectively) and forced expiratory volume in 1 s (FEV1) (r=−0.79 and r=−0.78, respectively). Two distinct 3He-MRI patterns were highlighted: patients with abnormal FEV1 had significantly (p<0.001) larger, but fewer, contiguous defects than those with normal FEV1, who tended to have numerous small volume defects. These two MRI patterns were delineated by a VDP of ∼10%. At total lung capacity, when compared to EIVT, VDP and VHI reduced in all subjects (p<0.001), demonstrating improved ventilation distribution and regions of volume-reversible and nonreversible ventilation abnormalities.


Respirology ◽  
2014 ◽  
Vol 19 (7) ◽  
pp. 1046-1051 ◽  
Author(s):  
David A. Kaminsky ◽  
Anees Daud ◽  
David G. Chapman

2008 ◽  
Vol 104 (4) ◽  
pp. 1094-1100 ◽  
Author(s):  
Sylvia Verbanck ◽  
Daniel Schuermans ◽  
Sophie Van Malderen ◽  
Walter Vincken ◽  
Bruce Thompson

It has long been assumed that the ventilation heterogeneity associated with lung disease could, in itself, affect the measurement of carbon monoxide transfer factor. The aim of this study was to investigate the potential estimation errors of carbon monoxide diffusing capacity (DlCO) measurement that are specifically due to conductive ventilation heterogeneity, i.e., due to a combination of ventilation heterogeneity and flow asynchrony between lung units larger than acini. We induced conductive airway ventilation heterogeneity in 35 never-smoker normal subjects by histamine provocation and related the resulting changes in conductive ventilation heterogeneity (derived from the multiple-breath washout test) to corresponding changes in diffusing capacity, alveolar volume, and inspired vital capacity (derived from the single-breath DlCO method). Average conductive ventilation heterogeneity doubled ( P < 0.001), whereas DlCO decreased by 6% ( P < 0.001), with no correlation between individual data ( P > 0.1). Average inspired vital capacity and alveolar volume both decreased significantly by, respectively, 6 and 3%, and the individual changes in alveolar volume and in conductive ventilation heterogeneity were correlated ( r = −0.46; P = 0.006). These findings can be brought in agreement with recent modeling work, where specific ventilation heterogeneity resulting from different distributions of either inspired volume or end-expiratory lung volume have been shown to affect DlCO estimation errors in opposite ways. Even in the presence of flow asynchrony, these errors appear to largely cancel out in our experimental situation of histamine-induced conductive ventilation heterogeneity. Finally, we also predicted which alternative combination of specific ventilation heterogeneity and flow asynchrony could affect DlCO estimate in a more substantial fashion in diseased lungs, irrespective of any diffusion-dependent effects.


Radiology ◽  
1966 ◽  
Vol 86 (1) ◽  
pp. 7-30 ◽  
Author(s):  
Herbert M. Loyd ◽  
S. Timothy String ◽  
Arthur B. DuBois

PEDIATRICS ◽  
1959 ◽  
Vol 24 (2) ◽  
pp. 181-193
Author(s):  
C. D. Cook ◽  
P. J. Helliesen ◽  
L. Kulczycki ◽  
H. Barrie ◽  
L. Friedlander ◽  
...  

Tidal volume, respiratory rate and lung volumes have been measured in 64 patients with cystic fibrosis of the pancreas while lung compliance and resistance were measured in 42 of these. Serial studies of lung volumes were done in 43. Tidal volume was reduced and the respiratory rate increased only in the most severely ill patients. Excluding the three patients with lobectomies, residual volume and functional residual capacity were found to be significantly increased in 46 and 21%, respectively. These changes correlated well with the roentgenographic evaluation of emphysema. Vital capacity was significantly reduced in 34% while total lung capacity was, on the average, relatively unchanged. Seventy per cent of the 61 patients had a signficantly elevated RV/TLC ratio. Lung compliance was significantly reduced in only the most severely ill patients but resistance was significantly increased in 35% of the patients studied. The serial studies of lung volumes showed no consistent trends among the groups of patients in the period between studies. However, 10% of the surviving patients showed evidence of significant improvement while 15% deteriorated. [See Fig. 8. in Source Pdf.] Although there were individual discrepancies, there was a definite correlation between the clinical evaluation and tests of respiratory function, especially the changes in residual volume, the vital capacity, RV/ TLC ratio and the lung compliance and resistance.


1980 ◽  
Vol 49 (6) ◽  
pp. 946-952 ◽  
Author(s):  
C. A. Bradley ◽  
N. R. Anthonisen

The effects of a variety of restrictive procedures on lung mechanics were studied in eight healthy subjects. Rib cage restriction decreased total lung capacity (TLC) by 43% and significantly increased elastic recoil and maximum expiratory flow (MEF). Subsequent immersion of four subjects with rib cage restriction resulted in no further change in either parameter; shifts of blood volume did not reverse recoil changes during rib cage restriction. Abdominal restriction decreased TLC by 40% and increased MEF and elastic recoil, but recoil was increased significantly less than was the case with rib cage restriction. Further, at a given recoil pressure, MEF was less during rib cage restriction than during either abdominal restriction or no restriction. Measurements of the unevenness of inspired gas distribution by the single-breath nitrogen technique showed increased unevenness during rib cage restriction, which was significantly greater than that during abdominal restriction. We conclude that lung volume restriction induces changes in lung function, but the nature of these changes depends on how the restriction is applied and therefore cannot be ascribed to low lung volume breathing per se.


Sign in / Sign up

Export Citation Format

Share Document