scholarly journals Factors leading to failure to diagnose pulmonary malignant tumors using endobronchial ultrasound with guide sheath within the target lesion

2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Yoichi Nishii ◽  
Taro Yasuma ◽  
Kentaro Ito ◽  
Yuta Suzuki ◽  
Fumiaki Watanabe ◽  
...  

Abstract Background The diagnostic yield of peripheral pulmonary lesions has significantly increased with the use of radial endobronchial ultrasound with guide sheath within the lesion. Here, we retrospectively evaluated factors leading to misdiagnosis of pulmonary malignant tumors using endobronchial ultrasound with the guide sheath within the lesion. Methods We assessed the final histopathological diagnosis of biopsy samples taken from 130 patients with lung malignant tumors that underwent endobronchial ultrasound with guide sheath within the lesion. Results Among 130 patients, 8 (6%) showed no definite malignant findings in biopsy samples but the presence of malignant cells (primary lung cancer 7, diffuse large B cell lymphoma 1) was subsequently confirmed by histopathological study of specimens taken by computed tomography-guided needle biopsy or surgery. Of the eight cases with diagnostic failure, the size of the biopsy sample was insufficient in five due to technical difficulties during the diagnostic procedure, and the diagnosis of malignant tumor was difficult in five cases because of extensive scarring tissue or central necrosis. Conclusions The results of this study showed that technical difficulties and/or pathological heterogeneity of the tumor might lead to failure to diagnose lung malignant tumor in cases using endobronchial ultrasound with guide sheath within the lesion.

2020 ◽  
Vol 19 ◽  
pp. 153303382094748
Author(s):  
Chunhua Xu ◽  
Wei Wang ◽  
Qi Yuan ◽  
Huidi Hu ◽  
Li Li ◽  
...  

Objective: To evaluate the diagnostic value of radial endobronchial ultrasound (R-EBUS) combination with rapid on-site evaluation (ROSE) guided transbronchial lung biopsy (TBLB) for peripheral pulmonary lesions. Methods: Peripheral pulmonary lesions identified by computed tomography underwent R-EBUS with or without ROSE randomly from February 2016 to August 2017. The diagnostic yield and the operation time were compared. Results: In total, 158 patients were involved in and completed this research, including 84 cases in the group of R-EBUS with ROSE, and 74 in the group without ROSE. The diagnostic yield of ROSE group was 85.7%. Among these positive cases, 69.4% cases were malignant tumors, and 30.6% cases were benign lesions. The operation time was (24.6 ± 6.3) min. In the group without ROSE, the diagnostic yield was 70.3%, including 35 malignant tumors (67.3%), and 17 benign lesions (32.7%). The operation time was (31.5 ± 6.8) min. There were significant differences between both groups in the diagnostic yield (χ2 = 5.556, P = 0.018) and in the operation time (t = 3.187, P < 0.01). No serious procedure related complications were observed, such as pneumothorax and hemorrhage. Conclusion: ROSE can improve the diagnostic yield, and shorten the operation time. R-EBUS combined with ROSE is a safe and effective technique for peripheral pulmonary lesions.


Respiration ◽  
2021 ◽  
pp. 1-9
Author(s):  
Kai-Lun Yu ◽  
Shun-Mao Yang ◽  
Huan-Jang Ko ◽  
Hui-Yu Tsai ◽  
Jen-Chung Ko ◽  
...  

<b><i>Background:</i></b> The diagnostic yield of peripheral pulmonary lesions (PPLs) using radial endobronchial ultrasound (EBUS) remains challenging without navigation systems. Cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) represents a recently developed technique, and its clinical utility remains to be investigated. <b><i>Objectives:</i></b> The aim of this study was to investigate the diagnostic yield of transbronchial biopsy (TBB) using a combination of CBCT-AF and radial EBUS. <b><i>Methods:</i></b> We recruited consecutive patients with PPLs who underwent radial EBUS-guided TBB, with or without AF, between October 2018 and July 2019. Following propensity score 1:1 matching, we recorded the procedure-related data and measured their efficacy and safety. <b><i>Results:</i></b> While 72 patients received EBUS-plus-AF, 235 patients received EBUS only. We included 53 paired patients following propensity score matching. The median size of lesions was 2.8 and 2.9 cm in the EBUS-plus-AF group and EBUS-only group, respectively. Diagnostic yield was higher in the former group (75.5 vs. 52.8%; <i>p</i> = 0.015). The diagnostic yield for the EBUS-plus-AF group was significantly higher for lesions ≤30 mm (73.5 vs. 36.1%; <i>p</i> = 0.002). Moreover, there was no significant difference in the complication rates (3.8 vs. 5.7%; <i>p</i> = 1.000). Twenty-four nodules (45.3%) were invisible by fluoroscopy in the EBUS-plus-AF group. All of them were identifiable on CBCT images and successfully annotated for AF. The mean radiation dose of total procedure, CBCT, and fluoroscopy was 19.59, 16.4, and 3.17 Gy cm<sup>2</sup>, respectively. <b><i>Conclusions:</i></b> TBB using a combination of CBCT-AF and EBUS resulted in a satisfactory diagnostic yield and safety.


2021 ◽  
pp. 1-3
Author(s):  
Axel Tobias Kempa

There are cases of peripheral lung nodules that are difficult to approach despite using ancillary diagnostic devices during multimodal bronchoscopy. The use of ultrathin bronchoscopes has shown superiority over standard thin bronchoscopes. We retrospectively evaluated whether substitution of the thin-bronchoscope by the ultrathin device during multimodal bronchoscopy improves lesion ultrasound visualization and diagnostic yield in patients with difficult-to-approach pulmonary lesions. The study comprised 44 out of 338 patients that underwent multimodal bronchoscopy at Matsusaka Municipal Hospital. The thin-bronchoscope with an external diameter of 4 mm was substituted by the ultrathin-bronchoscope with an external diameter of 3 mm when the radial endobronchial ultrasound showed that the probe position was not within the target lesion. The median diameter of the pulmonary tumors was 17.5 mm (range: 6.0–5.2.0 mm). The endobronchial ultrasound showed the probe’s position adjacent to the lesion in 12 cases and no visible lesion in 32 cases using a thin-bronchoscope. However, the endobronchial ultrasound views changed from adjacent to the lesion to within the lesion in nine cases, from no visible lesion to within the lesion in 17 cases, and from no visible lesion to adjacent to the lesion in nine cases after bronchoscope substitution. After substitution, the diagnostic yield was 80.8% in cases with the radial probe within the target lesion, 72.7% in cases with the probe adjacent to the target lesion, and 0% in cases with no visible lesion. The overall diagnostic yield was 65.9% after bronchoscope substitution. The substitution of the thin bronchoscope by the ultrathin device on a need basis improves the position of the radial endobronchial ultrasound probe and diagnostic yield of pulmonary lesions during multimodal diagnostic bronchoscopy.


CHEST Journal ◽  
2010 ◽  
Vol 138 (4) ◽  
pp. 845A
Author(s):  
Jamsak Tscheikuna ◽  
Supawadee Makanut ◽  
Supparerk Disayabutr

Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 41
Author(s):  
Ching-Kai Lin ◽  
Hung-Jen Fan ◽  
Zong-Han Yao ◽  
Yen-Ting Lin ◽  
Yueh-Feng Wen ◽  
...  

Background: Endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) is used for the diagnosis of peripheral pulmonary lesions (PPLs), but the diagnostic yield is not adequate. Cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) can be utilized to assess the location of PPLs and biopsy devices, and has the potential to improve the diagnostic accuracy of bronchoscopic techniques. The purpose of this study was to verify the contribution of CBCT-AF to EBUS-TBB. Methods: Patients who underwent EBUS-TBB for diagnosis of PPLs were enrolled. The navigation success rate and diagnostic yield were used to evaluate the effectiveness of CBCT-AF in EBUS-TBB. Results: In this study, 236 patients who underwent EBUS-TBB for PPL diagnosis were enrolled. One hundred fifteen patients were in CBCT-AF group and 121 were in non-AF group. The navigation success rate was significantly higher in the CBCT-AF group (96.5% vs. 86.8%, p = 0.006). The diagnostic yield was even better in the CBCT-AF group when the target lesion was small in size (68.8% vs. 0%, p = 0.026 for lesions ≤10 mm and 77.5% vs. 46.4%, p = 0.016 for lesions 10–20 mm, respectively). The diagnostic yield of the two study groups became similar when the procedures with a failure of navigation were excluded. The procedure-related complication rate was similar between the two study groups. Conclusion: CBCT-AF is safe, and effectively enhances the navigation success rate, thereby increasing the diagnostic yield of EBUS-TBB for PPLs.


2016 ◽  
Vol 42 (4) ◽  
pp. 248-253 ◽  
Author(s):  
Marcia Jacomelli ◽  
Sergio Eduardo Demarzo ◽  
Paulo Francisco Guerreiro Cardoso ◽  
Addy Lidvina Mejia Palomino ◽  
Viviane Rossi Figueiredo

ABSTRACT Objective: Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. Methods: We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy), we used fluoroscopy. Results: Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ± 0.7 cm) and 19 masses (mean diameter, 4.1 ± 0.9 cm). The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS). Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7%) and bronchial bleeding, which was controlled bronchoscopically (in 9.3%). Conclusions: Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions.


2019 ◽  
Vol 17 (2) ◽  
pp. 26-30
Author(s):  
Shahe Systa Mosarrat ◽  
Md Zillur Rahman ◽  
M Shahab Uddin Ahamad ◽  
Pradip Bhattacharjee ◽  
Sayeeda Nasreen ◽  
...  

Background: Diseases of the breast constitute a significant proportion of surgical cases and frequently, the need arises to distinguish benign from malignant lesions prior to definitive treatment. So far, Frozen Section (FS) is the standard technique with high level of validity. However, intraoperative scrape cytology can be adopted when special facilities of FS are not available. Methods: This study designed with the aim to evaluate the value of Intraoperative Scrape Cytology (IOSC) in providing rapid and accurate diagnosis for breast lump and to compare its diagnostic yield with that of paraffin sections. This cross sectional descriptive study was carried out in the Department of Pathology, Chittagong Medical College in collaboration with Department of Surgery of this institution from October 2013 to September 2014. The study conducted on 123 patients with breast lumps who underwent operative treatment. Scrapings were taken from each specimen before formalin fixation and stained by rapid Papanicolaou staining. In each case their accuracy was compared to histopathological diagnosis. Statistical analysis done employing c2 test. Results: Out of 123 cases studied, 122 could be correctly differentiated into benign and malignant tumors with an accuracy rate of 99.19%. Conclusion: Intraoperative Scrape Cytology (IOSC) is a simple, accurate, rapid and cost-effective diagnostic tool, not requiring specific instruments in contrast to frozen section, can be used peroperatively for both diagnosis and management of breast lump. Chatt Maa Shi Hosp Med Coll J; Vol.17 (2); Jul 2018; Page 26-30


Sign in / Sign up

Export Citation Format

Share Document