peripheral pulmonary lesions
Recently Published Documents


TOTAL DOCUMENTS

281
(FIVE YEARS 114)

H-INDEX

26
(FIVE YEARS 5)

2022 ◽  
Vol 22 (1) ◽  
Author(s):  
Toshiyuki Nakai ◽  
Tetsuya Watanabe ◽  
Yuto Kaimi ◽  
Koichi Ogawa ◽  
Yoshiya Matsumoto ◽  
...  

Abstract Background A balloon occlusion technique is suggested for use in cryobiopsy for interstitial lung diseases because of the bleeding risk. However, it may interfere with selection of the involved bronchus for peripheral pulmonary lesions (PPLs). A two-scope technique, in which two scopes are prepared and hemostasis is started using the second scope immediately after cryobiopsy, has also been reported. This study aimed to evaluate the safety and diagnostic utility of transbronchial cryobiopsy using the two-scope technique for PPLs. Methods Data of patients who underwent conventional biopsy followed by cryobiopsy using the two-scope technique for PPLs from November 2019 to March 2021 were collected. The incidence of complications and risk factors for clinically significant bleeding (moderate to life-threatening) were investigated. Diagnostic yields were also compared among conventional biopsy, cryobiopsy, and the combination of them. Results A total of 139 patients were analyzed. Moderate bleeding occurred in 25 (18.0%) patients without severe/life-threatening bleeding. Although five cases required transbronchial instillation of thrombin, all bleeding was completely controlled using the two-scope technique. Other complications included two pneumothoraces and one asthmatic attack. On multivariable analysis, only ground-glass features (P < 0.001, odds ratio: 9.30) were associated with clinically significant bleeding. The diagnostic yields of conventional biopsy and cryobiopsy were 76.3% and 81.3%, respectively (P = 0.28). The total diagnostic yield was 89.9%, significantly higher than conventional biopsy alone (P < 0.001). Conclusions The two-scope technique provides useful hemostasis for safe cryobiopsy for PPLs, with a careful decision needed for ground-glass lesions.


Diagnostics ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 41
Author(s):  
Ching-Kai Lin ◽  
Hung-Jen Fan ◽  
Zong-Han Yao ◽  
Yen-Ting Lin ◽  
Yueh-Feng Wen ◽  
...  

Background: Endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) is used for the diagnosis of peripheral pulmonary lesions (PPLs), but the diagnostic yield is not adequate. Cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) can be utilized to assess the location of PPLs and biopsy devices, and has the potential to improve the diagnostic accuracy of bronchoscopic techniques. The purpose of this study was to verify the contribution of CBCT-AF to EBUS-TBB. Methods: Patients who underwent EBUS-TBB for diagnosis of PPLs were enrolled. The navigation success rate and diagnostic yield were used to evaluate the effectiveness of CBCT-AF in EBUS-TBB. Results: In this study, 236 patients who underwent EBUS-TBB for PPL diagnosis were enrolled. One hundred fifteen patients were in CBCT-AF group and 121 were in non-AF group. The navigation success rate was significantly higher in the CBCT-AF group (96.5% vs. 86.8%, p = 0.006). The diagnostic yield was even better in the CBCT-AF group when the target lesion was small in size (68.8% vs. 0%, p = 0.026 for lesions ≤10 mm and 77.5% vs. 46.4%, p = 0.016 for lesions 10–20 mm, respectively). The diagnostic yield of the two study groups became similar when the procedures with a failure of navigation were excluded. The procedure-related complication rate was similar between the two study groups. Conclusion: CBCT-AF is safe, and effectively enhances the navigation success rate, thereby increasing the diagnostic yield of EBUS-TBB for PPLs.


2021 ◽  
Vol 31 (6) ◽  
pp. 718-728
Author(s):  
Yana O. Chesalina ◽  
Natalya L. Karpina ◽  
Yuri S. Berezovskij ◽  
Svetlana V. Shishova ◽  
Ilya V. Sivokozov

Data regarding the efficacy of virtual bronchoscopy (VB) compared to radial endobronchial ultrasound (rEBUS) for minimally invasive diagnostics of peripheral pulmonary lesions (PPLs) are still controversial.Aim. To assess the comparative efficacy of VB versus VB plus rEBUS in patients with PPLs.Methods. The study enrolled 36 subjects with PPLs detected by chest high resolution computed tomography (HRCT). All patients had bronchoscopy with various biopsy methods (based on navigation) alone or in combination with each other, followed by cytological, histological (if the biopsy sample was available), and microbiological analysis of the specimens. The subjects were randomized into two groups depending on the navigation technique: VB + rEBUS group (I) and VB group (II). VB (Osirix) was done as a planning procedure before real bronchoscopy with rEBUS navigation (Olympus UM-S20-17S) in group I. In group II VB was the only navigation technique.Results. Overall diagnostic yield (d. y.) reached 60% and 56% for groups I and II, respectively. In group I, the d.y. reached 86% for malignancy and 42% for other benign diseases. In group II, the d.y. reached 100% for malignancy and 36% for other benign diseases. The navigation efficacy was higher in the presence of a draining bronchus sign according to chest HRCT, lesion size more than 20 mm, upper lobe peripheral lesion. In group I, detecting the lesion with the ultrasound radial mini probe was also a predictor of efficacy. In group II, abnormal intraluminal bronchial anatomy according to VB as a sign of central lung cancer was also a predictor of efficacy.Conclusion. Both rEBUS and VB are safe and effective navigation techniques that provide for highly effective minimally invasive diagnosis of PPLs. VB could be a sound alternative when rEBUS is unavailable.


Diagnostics ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 2269
Author(s):  
Takayasu Ito ◽  
Tomoki Kimura ◽  
Kensuke Kataoka ◽  
Shotaro Okachi ◽  
Keiko Wakahara ◽  
...  

The occurrence of interstitial lung disease (ILD) with peripheral pulmonary lesions (PPLs) is closely linked to the development of lung cancer. Yet, the best diagnostic approach for identifying PPLs in patients with ILD remains elusive. This study retrospectively investigated the application of transbronchial biopsy (TBB) using endobronchial ultrasonography with a guide sheath (EBUS-GS) to the effective and safe diagnosis of PPLs when compared with conventional TBB. The study sample included a consecutive series of 19 patients with ILD who underwent conventional TBB or TBB using EBUS-GS at Tosei General Hospital between 1 April 2013 and 31 October 2015. The two techniques were compared based on diagnostic yield and associated complications. The diagnostic yield of EBUS-GS TBB was significantly higher than that of conventional TBB (p = 0.009), especially for small lesions (≤20 mm), lesions located in the lower lobes, lesions with a positive bronchus sign, and lesions visible by chest radiography (p = 0.010, p = 0.022, p = 0.006, and p = 0.002, respectively). There were no significant differences in complication rates. Therefore, EBUS-GS is an effective alternative for the diagnosis of PPLs in patients with ILD, without additional complications.


2021 ◽  
Vol 57 (12) ◽  
pp. 772-774
Author(s):  
Felipe Andreo García ◽  
Mohamed Torky ◽  
Carmen Centeno Clemente ◽  
Pere Serra Mitjà ◽  
Antoni Rosell Gratacós ◽  
...  

2021 ◽  
Vol 10 (23) ◽  
pp. 5678
Author(s):  
Michael Lu ◽  
Sridesh Nath ◽  
Roy W. Semaan

Robotic-assisted bronchoscopy is one of the newest additions to clinicians’ armamentarium for the biopsy of peripheral pulmonary lesions in light of the suboptimal yields and sensitivities of conventional bronchoscopic platforms. In this article, we review the existing literature pertaining to the feasibility as well as sensitivity of available robotic-assisted bronchoscopic platforms.


Cancers ◽  
2021 ◽  
Vol 13 (22) ◽  
pp. 5751
Author(s):  
Takayasu Ito ◽  
Shotaro Okachi ◽  
Tomoki Kimura ◽  
Kensuke Kataoka ◽  
Yasuhiko Suzuki ◽  
...  

In patients with interstitial lung disease (ILD), the most frequent locations of lung cancer are within or near fibrotic lesions. However, the diagnostic yield for peripheral pulmonary lesions (PPLs) within or near fibrotic lesions using endobronchial ultrasonography with a guide sheath transbronchial biopsy (EBUS-GS TBB) may be unsatisfactory compared to that for PPLs distant from fibrotic lesions because of the difficulty in reaching the lesions. Our objectives were to evaluate the yield for PPLs using EBUS-GS TBB according to the proximity of PPLs to fibrotic lesions and to determine factors affecting the yield for PPLs. We retrospectively investigated 323 consecutive lesions using EBUS-GS TBB between 1 November 2014 and 31 December 2016. We identified PPLs with ILD in such lesions. PPLs with ILD were divided into PPLs within or near fibrotic lesions which met the criterion of PPLs, and of fibrotic lesions overlapping each other (PPLs-FL) and those distant from fibrotic lesions, which met the criterion of PPLs and the area of fibrotic lesion not overlapping each other (PPLs-NFL). Of the 323 lesions, 55 were included (31 PPLs-FL and 24 PPLs-NFL). The diagnostic yield for PPLs-FL was significantly lower than for PPLs-NFL (45.2% vs. 83.3%, p = 0.004). Multivariate analysis revealed that PPLs-NFL (odds ratio (OR) = 7.509) and a probe position within the lesion (OR = 4.172) were significant factors affecting diagnostic yield. Lesion’s positional relation to fibrotic lesions and the probe position were important factors affecting the successful diagnosis via EBUS-GS TBB in these patients.


2021 ◽  
Author(s):  
Midori Tanaka ◽  
Yuji Matsumoto ◽  
Tatsuya Imabayashi ◽  
Takuya Kawahara ◽  
Takaaki Tsuchida

Abstract Background: Cryobiopsy is an established technique that yields larger and higher-quality samples than does a forceps biopsy. However, it remains underutilised in the diagnosis of peripheral pulmonary lesions (PPLs), mainly because of difficulties in handling conventional cryoprobes. A recently introduced single-use cryoprobe with a smaller diameter and more flexibility than conventional ones may improve its diagnostic ability for PPLs. We conducted this prospective study to evaluate the feasibility of transbronchial cryobiopsy in the diagnoses of PPLs, using a new 1.7-mm cryoprobe. Methods: The study included patients with PPLs less than 30 mm in diameter scheduled to undergo bronchoscopy. All the procedures were performed using a combination of virtual bronchoscopic navigation, radial endobronchial ultrasound (R-EBUS) and X-ray fluoroscopy, and all the samples were collected using the cryoprobe alone. Thereafter, we assessed the diagnostic outcomes and safety profiles.Results: A total of 50 patients were enrolled and underwent cryobiopsy. The median lesion size was 20.8 mm (range, 8.2–29.6 mm), and the negative bronchus sign was seen in 34% of lesions. The diagnostic yield was 94% (95% confidence interval, 83.5–98.8%). A positive bronchus sign had a significantly higher diagnostic yield than did a negative bronchus sign (100% vs. 82.4%; P=0.035). The yield was achieved regardless of other variables, including lesion size, location, and R-EBUS findings. The major complications were mild and moderate bleeding in 28% and 62% of patients, respectively. Pneumothorax was identified in one patient.Conclusion: Transbronchial cryobiopsy using the new 1.7-mm cryoprobe is a feasible procedure that has the potential to increase the diagnostic accuracy for PPLs.Trial Registration: Japan Registry of Clinical Trials, jRCT1032200065. Registered 8 July 8 2020, https://jrct.niph.go.jp/en-latest-detail/jRCT1032200065


Sign in / Sign up

Export Citation Format

Share Document