scholarly journals Application of 3D printing and framework internal fixation technology for high complex rib fractures

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Xuetao Zhou ◽  
Dongsheng Zhang ◽  
Zexin Xie ◽  
Yang Yang ◽  
Menghui Chen ◽  
...  

Abstract Objective To explore the clinical effect of 3D printing combined with framework internal fixation technology on the minimally invasive internal fixation of high complex rib fractures. Methods Total 16 patients with high complex rib fractures were included in the study. Before the procedure, the 3D rib model was reconstructed based on the thin-layer chest CT scan. According to the 3D model, the rib locking plate was pre-shaped, and the preoperative planning were made including the direction of the locking plate, the location of each nail hole and the length of the screw. During the operation, the locking plate was inserted from the sternum to the outermost fracture lines of ribs with screws at both ends. In addition, the locking plate was used as the frame to sequentially reduce the middle fracture segment and fix with screws or steel wires. Chest x-rays or chest CT scans after surgery were used to assess the ribs recovery. All patients were routinely given non-steroidal anti-inflammatory drugs (NSAIDS) for analgesia, and the pain level was evaluated using numerical rating scale (NRS). Results The preoperative planning according to the 3D printed rib model was accurate. The reduction and fixation of each fracture segment were successfully completed through the framework internal fixation technology. No cases of surgical death, and postoperative chest pain was significantly alleviated. Five to 10 months follow up demonstrated neither loosening of screws, nor displacement of fixtures among patients. The lungs of each patients were clear and in good shape. Conclusion The application of 3D printing combined with framework internal fixation technology to the high complex rib fractures is beneficial for restoring the inherent shape of the thoracic cage, which can realize the accurate and individualized treatment as well as reduces the operation difficulty.

2020 ◽  
Author(s):  
Xuetao Zhou ◽  
Dongsheng Zhang ◽  
Zexin Xie ◽  
Yang Yang ◽  
Menghui Chen ◽  
...  

Abstract Objective To explore the clinical effect of 3D printing combined with framework internal fixation technology on the minimally invasive internal fixation of high complex rib fractures. Methods Total 16 patients with high complex rib fractures were included in the study. Before the procedure, the 3D rib model was reconstructed based on the thin-layer chest CT scan. According to the 3D model, the rib locking plate was pre-shaped, and the preoperative planning were made including the direction of the locking plate, the location of each nail hole and the length of the screw. During the operation, the locking plate was inserted from the sternum to the outermost fracture lines of ribs with screws at both ends. In addition, the locking plate was used as the frame to sequentially reduce the middle fracture segment and fix with screws or steel wires. Chest x-rays or chest CT scans after surgery were used to assess the ribs recovery. All patients were routinely given non-steroidal anti-inflammatory drugs (NSAIDS) for analgesia, and the pain level was evaluated using numerical rating scale (NRS). Results The preoperative planning according to the 3D printed rib model was accurate. The reduction and fixation of each fracture segment were successfully completed through the framework internal fixation technology. No cases of surgical death, and postoperative chest pain was significantly alleviated. Five to ten months follow up demonstrated neither loosening of screws, nor displacement of fixtures among patients. The lungs of each patients were clear and in good shape. Conclusion The application of 3D printing combined with framework internal fixation technology to the high complex rib fractures is beneficial for restoring the inherent shape of the thoracic cage, which can realize the accurate and individualized treatment as well as reduces the operation difficulty.


2020 ◽  
Author(s):  
Xuetao Zhou ◽  
Dongsheng Zhang ◽  
Zexin Xie ◽  
Yang Yang ◽  
Menghui Chen ◽  
...  

Abstract Objective: To explore the clinical effect of 3D printing combined with framework internal fixation technology on the minimally invasive internal fixation of high complex rib fractures.Methods: Total 16 patients with high complex rib fractures were included in the study. Before the procedure, the 3D rib model was reconstructed based on the thin-layer chest CT scan. According to the 3D model, the rib locking plate was pre-shaped, and the preoperative planning were made including the direction of the locking plate, the location of each nail hole and the length of the screw. During the operation, the locking plate was inserted from the sternum to the outermost fracture lines of ribs with screws at both ends. In addition, the locking plate was used as the frame to sequentially reduce the middle fracture segment and fix with screws or steel wires. Chest x-rays or chest CT scans after surgery were used to assess the ribs recovery. All patients were routinely given non-steroidal anti-inflammatory drugs (NSAIDS) for analgesia, and the pain level was evaluated using numerical rating scale (NRS). Results: The preoperative planning according to the 3D printed rib model was accurate. The reduction and fixation of each fracture segment were successfully completed through the framework internal fixation technology. No cases of surgical death, and postoperative chest pain was significantly alleviated. Five to ten months follow up demonstrated neither loosening of screws, nor displacement of fixtures among patients. The lungs of each patients were clear and in good shape.Conclusion: The application of 3D printing combined with framework internal fixation technology to the high complex rib fractures is beneficial for restoring the inherent shape of the thoracic cage, which can realize the accurate and individualized treatment as well as reduces the operation difficulty.


2019 ◽  
Vol 43 (1) ◽  
pp. 35-47
Author(s):  
Jing Xu ◽  
Guodong Zhang ◽  
Zaopeng He ◽  
Shizhen Zhong ◽  
Yongshao Chen ◽  
...  

Abstract To evaluate and precisely internal fix intra-articular distal radial fracture (IDRF) using the virtual X-ray and three-dimensional (3D) printing technologies. Twenty-one patients with IDRF were recruited, and the data from digital design group (DDG) and real surgery group (RSG) were collected and analyzed. In DDG, the data from thin-slice computed tomography scan, virtual X-ray measurement parameters, including volar tilt, palmar tilt, radius length (D1), ulnar variation (D2), locking plate position parameter (D3) and distance between key nail and joint surface (D4) were collected. The bone was virtually fixed with the locking plate, and the final model of radius with the screw was obtained by 3D printing. In RSG, the locking plate was precisely pre-bended and used in surgery. During the surgery, the key K-wire was accurately placed and the locking plate was adjusted with the aid of the U-shaped navigation arm. The C-arm was used to observe the positions of key K-wires and the locking plate, and the same above-mentioned parameters were measured intra- and post-operatively. The data from RSG and DDG were compared statistically by t test. This approach proved to be successful in all 21 patients, and none of the screws pierced through the wrist joint surface. All the measured parameters, including the volar tilt, palmar tilt, D1–4, in RSG were not significantly different from preoperative DDG data. Virtual X-ray measurement of anatomical reduction parameters and 3D printing can help the anatomical reduction and precise internal fixation by providing quantitative references, preoperatively, intraoperatively and postoperatively.


2021 ◽  
Vol 42 (5) ◽  
pp. 1094-1101
Author(s):  
Yu-bin Ha ◽  
Han-sol Jang ◽  
Gil-cho Shin

Objectives: This study examined a case of chronic intestinal pseudo-obstruction (CIPO) in an adult with unspecified abdominal pain.Methods: The patient was treated with herbal medicine, acupuncture, and moxa. Treatment progress was evaluated by follow-up monitoring of the intensity, frequency, and duration (in hours) of abdominal pain and body weight.Results: The average abdominal pain level on the Numerical Rating Scale (NRS) and its incidence decreased. The duration of pain was 15 hours maximum and 2.5 hours minimum. The body weight repeatedly increased and decreased but increased overall. Despite no remarkable findings from X-rays, air-fluid levels and coil-shaped folds of the small bowel were observed.Conclusions: Korean medical treatment based on a dialectic effectively relieved chronic abdominal pain and suspected CIPO-a disease that requires continuous management and therapeutic intervention.


2020 ◽  
Vol 14 (3) ◽  
pp. 350-356
Author(s):  
Tomer Bezalel ◽  
Eli Carmeli ◽  
Leonid Kalichman

Study Design: Cross-sectional and follow-up nested study.Purpose: To assess the reliability of the L5-kyphosis apex line (L5-KAL) evaluation and determine the association between changes in L5-KAL, changes in radiological parameters, and changes in clinical symptoms.Overview of Literature: Scheuermann’s disease is the most common cause of hyperkyphosis of the thoracolumbar and thoracic spine during adolescence. Scheuermann’s disease patients usually show compensatory hyperlordosis of the lumbar spine, which is usually flexible, and express an anterior translation of the lumbar section. The L5-KAL was developed on the basis of our clinical experience, displaying the horizontal distance between the thoracic and lumbar curves.Methods: In the cross-sectional segment, 150 initial lateral X-rays of patients with Scheuermann’s disease and postural kyphosis were analyzed, and 80 additional X-rays were analyzed in the follow-up segment. The data taken from the X-rays of the whole spinal column included the thoracic kyphosis angle, the C7 plumb line, and the L5-KAL. Clinical data included a numerical rating scale of self-perceived body image, pain, and a Scoliosis Research Society-22 questionnaire (SRS-22).Results: Significant positive associations were observed in a cross-sectional study between the L5-KAL and thoracic kyphosis, lumbar lordosis, C7 line, and self-perceived body image. In the follow-up nested study, in a mixed analysis of variance, the main effect of time was significant for the L5-KAL, kyphotic deformity and SRS-22, which indicated a change in these parameters after treatment of Scheuermann’s disease patients. Significant positive associations were observed between the changes in L5-KAL and the changes in thoracic kyphosis.Conclusions: Our evidence suggests that the L5-KAL can serve as an indicator of the thoracic curve change in Scheuermann’s disease and postural kyphosis patients and should be considered in clinical practice.


2017 ◽  
Vol 07 (02) ◽  
pp. 127-132
Author(s):  
Schneider Rancy ◽  
Eugene Ek ◽  
Sophia Paul ◽  
Robert Hotchkiss ◽  
Scott Wolfe

Purpose This study aims to compare the outcomes and complications of our technique for nonspanning total wrist arthrodesis using a locking plate with the standard carpometacarpal spanning technique. Methods A retrospective review of charts was performed to identify patients who underwent total wrist arthrodesis by the senior author (S.W.W.). We compared the outcomes of 15 cases of nonspanning wrist fusion with a 2.4/2.7 mm locking T plate to 11 cases of spanning wrist fusion with a 2.7/3.5 mm locking compression plate. Minimum follow-up was 3 months. Indications for fusion included rheumatoid arthritis, posttraumatic arthritis, Kienböck's disease, primary osteoarthritis, juvenile inflammatory arthropathy, psoriasis, brachial plexopathy, failed hemi or total wrist arthroplasty, failed four-corner fusion, and failed proximal row carpectomy. The primary outcome was fusion. Secondary outcomes included time to union, patient-rated wrist evaluation score, numerical rating scale pain score, grip strength, and complications. Results All the wrists got fused. There were no significant differences in objective and subjective outcomes between cohorts. There were three complications (27%) in the spanning group, including tendon rupture and peri-implant fracture at the third metacarpal. This was compared with three complications (20%) in the nonspanning group, consisting of hardware removal. Discussion We achieved similar fusion rates employing both spanning and nonspanning total wrist arthrodesis techniques, without necessitating carpometacarpal arthrodesis in the latter. Complications associated with our method were comparably less severe than those reported in the literature. We advocate nonspanning arthrodesis as an alternative method for total wrist fusion with a high union rate and minimal risk of complications at the carpometacarpal joint. Level of Evidence Therapeutic level IV.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Weiming Wu ◽  
Tiancheng Zhao ◽  
Yang Li ◽  
Xiang Guo ◽  
Weiwei He ◽  
...  

Abstract Background This study aimed to investigate the pulmonary ventilation function (PVF) according to different types of rib fractures and pain levels. Methods This was a retrospective study of patients with thoracic trauma admitted to our ward from May 1, 2015, to February 1, 2017. Vital capacity (VC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF) were measured on admission. A numerical rating scale (NRS) was used for pain assessment. Results A total of 118 (85 males and 33 females) were included. The location of rib fractures did not affect the PVF. When the number of rib fractures was ≥5, the PVF was lower than in those with ≤4 fractures (VC: 0.40 vs. 0.47, P = 0.009; FEV1: 0.37 vs. 0.44, P = 0.012; PEF: 0.17 vs. 0.20, P = 0.031). There were no difference in PVF values between rib fractures with multiple locations and those with non-multiple locations (VC: 0.41 vs. 0.43, P = 0.202; FEV1: 0.37 vs. 0.39, P = 0.692; PEF: 0.18 vs. 0.18, P = 0.684). When there were ≥ 5 breakpoints, the PVF parameters were lower than those with ≤4 breakpoints (VC: 0.40 vs. 0.50, P = 0.030; FEV1: 0.37 vs. 0.45, P = 0.022; PEF: 0.18 vs. 0.20, P = 0.013). When the NRS ≥ 7, the PVF values were lower than for those with NRS ≤ 6 (VC: 0.41 vs. 0.50, P = 0.003; FEV1: 0.37 vs. 0.47, P = 0.040; PEF: 0.18 vs. 0.20, P = 0.027). Conclusions When the total number of fractured ribs is ≥5, there are ≥5 breakpoints, or NRS is ≥7, the VC, FEV1, and PEF are more affected. Trial registration The trial was conducted in accordance with the Declaration of Helsinki (as revised in 2013). The study was approved by the Ethics Committee of Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, and individual consent for this retrospectively registered analysis was waived.


2020 ◽  
Vol 8 (1) ◽  
pp. 21-21
Author(s):  
Mani Mofidi ◽  
Ali Dashti ◽  
Mahdi Rezai ◽  
Niloufar Ghodrati ◽  
Hoorolnesa Ameli ◽  
...  

Introduction: This study was designed to compare the effectiveness of intravenous morphine with nebulized morphine in pain relief of patients referring to the emergency setting with traumatic musculoskeletal pain. Methods: This randomized, placebo-controlled and double-blind clinical study evaluated 160 patients 18 to 65 years of age with acute traumatic pain, who attended the emergency department during 2019. Subjects were assessed with Numerical Rating Scale based on inclusion and exclusion criteria and randomly divided into two groups. In one group, 80 patients received IV morphine (0.1 mg/kg+5 mL normal saline) plus an equivalent volume of IV placebo. In the second group, 80 patients received nebulized morphine (0.2 mg/kg+5 mL normal saline) plus nebulized placebo. Pain score was monitored in all patients with Numerical Rating Scale before and after intervention at baseline, 15, 30, 45, and 60-minute intervals. Patients’ vital signs and possible adverse events were evaluated in each observation time points. Finally, all participants were assessed for their satisfaction with pain management. Data were analyzed using repeated measure analysis for continuous variables and Binomial test for categorical variables Results: There was no significant difference between the demographic characteristics of patients in study groups. Pain relief between the two groups was similar during the observation (0, 15, 30, 45, 60 min) (P>0.05). There were no changes in vital signs between two groups, although the nebulized group had lower systolic blood pressure at the time-point of 15 minutes after the treatment initiation (P=0.03). Conclusion: Although Nebulized morphine has similar efficacy in comparison with IV route, nebulization might be considered as the clinically efficacious route of morphine administration with minimal side effects, providing optimal pain relief in patients.


2020 ◽  
Vol 103 (10) ◽  
pp. 1028-1035

Background: Craniotomy causes acute and chronic pain. Uncontrolled postoperative pain may lead to adverse events. Perioperative scalp nerves block is not only effective in reducing intraoperative hemodynamic response, but it also reduces postoperative pain and postoperative analgesia requirement. Objective: To compare the benefits of adding dexmedetomidine to levobupivacaine in scalp nerves block before craniotomy for the duration of analgesia in supratentorial craniotomy. Materials and Methods: After approval by the Committee for Research, 50 supratentorial craniotomy patients were randomized into two groups. The control group received 30 mL scalp nerves block with 0.25% levobupivacaine with adrenaline 1:200,000, whereas the study group received 30 mL scalp nerves block with 0.25% levobupivacaine with adrenaline 1:200,000 plus dexmedetomidine 1 mcg/kg. The primary outcome was the time to first analgesic requirement postoperatively. The secondary outcomes included intraoperative fentanyl consumption, verbal numerical rating scale, tramadol consumption, and complications during the first 24 hours postoperatively. Results: Patients in the study group had significantly increase time to the first analgesic requirement in postoperative period and reduced intraoperative fentanyl consumption. The median time to first analgesic requirement was 555 (360 to 1,035) minutes in the study group versus 405 (300 to 520) minutes in the control group (p=0.023). Intraoperative fentanyl consumption 125 (75 to 175) mcg in the study group was significantly lower than 200 (150 to 250) mcg in the control group (p=0.02). The verbal numerical rating scale at 1, 4, 8, 12 and 24 hours postoperatively, tramadol consumption, and complications during the first 24 hours postoperatively were not statistically significant different. Conclusion: Preoperative scalp nerves block with 0.25% levobupivacaine with adrenaline (1:200,000) with dexmedetomidine 1 mcg/kg significantly increased the time to first analgesic requirement and reduced intraoperative fentanyl consumption compared to 0.25% levobupivacaine with adrenaline (1:200,000) without perioperative complications. Keywords: Scalp block, Dexmedetomidine, Post-craniotomy analgesia, Supratentorial tumor, Levobupivacaine


BMJ Open ◽  
2020 ◽  
Vol 10 (2) ◽  
pp. e034003
Author(s):  
Kun Peng ◽  
Min Zeng ◽  
Jia Dong ◽  
Xiang Yan ◽  
Dexiang Wang ◽  
...  

IntroductionScalp nerve block has been proven to be an alternative choice to opioids in multimodal analgesia. However, for the infratentorial space-occupying craniotomy, especially the suboccipital retrosigmoid craniotomy, scalp nerve block is insufficient.Methods and analysisThe study is a prospective, single-centre, randomised, paralleled-group controlled trial. Patients scheduled to receive elective suboccipital retrosigmoid craniotomy will be randomly assigned to the superficial cervical plexus block group or the control group. After anaesthesia induction, superficial cervical plexus nerve block will be performed under the guidance of ultrasound. The primary outcome is the cumulative consumption of sufentanil by the patient-controlled intravenous analgesia pump within 24 hours after surgery. Secondary outcomes include the cumulative consumption of sufentanil at other four time points and numerical rating scale pain severity score.Ethics and disseminationThe protocol (version number: 2.0, 10 April 2019) has been approved by the Ethics Review Committee of China Registered Clinical Trials (Ethics Review No. ChiECRCT-20190047). The findings of this study will be disseminated in peer-reviewed journals and at scientific conferences.Trial registration numberNCT04036812


Sign in / Sign up

Export Citation Format

Share Document