scholarly journals Point-of-care ultrasound in primary care: a systematic review of generalist performed point-of-care ultrasound in unselected populations

2019 ◽  
Vol 11 (1) ◽  
Author(s):  
Bjarte Sorensen ◽  
Steinar Hunskaar

Abstract Background Both the interest and actual extent of use of point-of-care ultrasound, PoCUS, among general practitioners or family physicians are increasing and training is also increasingly implemented in residency programs. However, the amount of research within the field is still rather limited compared to what is seen within other specialties in which it has become more established, such as in the specialty of emergency medicine. An assumption is made that what is relevant for emergency medicine physicians and their populations is also relevant to the general practitioner, as both groups are generalists working in unselected populations. This systematic review aims to examine the extent of use and to identify clinical studies on the use of PoCUS by either general practitioners or emergency physicians on indications that are relevant for the former, both in their daily practice and in out-of-hours services. Methods Systematic searches were done in PubMed/MEDLINE using terms related to general practice, emergency medicine, and ultrasound. Results On the extent of use, we identified 19 articles, as well as 26 meta-analyses and 168 primary studies on the clinical use of PoCUS. We found variable, but generally low, use among general practitioners, while it seems to be thoroughly established in emergency medicine in North America, and increasingly also in the rest of the world. In terms of clinical studies, most were on diagnostic accuracy, and most organ systems were studied; the heart, lungs/thorax, vessels, abdominal and pelvic organs, obstetric ultrasound, the eye, soft tissue, and the musculoskeletal system. The studies found in general either high sensitivity or high specificity for the particular test studied, and in some cases high total accuracy and superiority to other established diagnostic imaging modalities. PoCUS also showed faster time to diagnosis and change in management in some studies. Conclusion Our review shows that generalists can, given a certain level of pre-test probability, safely use PoCUS in a wide range of clinical settings to aid diagnosis and better the care of their patients.

2020 ◽  
Author(s):  
Dima Touhami ◽  
Christoph Merlo ◽  
Joachim Hohmann ◽  
Stefan Essig

Abstract Background Ultrasound imaging is utilized in Swiss primary care; however, little is known regarding the extent to which it is performed. A course in Point-of-Care ultrasound (POCUS) has been recently introduced to promote and improve the utilization of ultrasound. POCUS will offer faster certification compared to previous courses thanks to a limited set of targeted examinations. With this study, we aim to (1) provide an overview of ultrasound use by general practitioners (GPs), and (2) determine how the clinical uses of ultrasound relate to the targeted objectives of POCUS. Methods This is a quantitative study, analyzing fifteen years of billing data from 213 GPs in Central Switzerland and cross-sectional survey data completed by 61 GPs attending 26 certification and refresher courses offered by the Swiss Society of Ultrasound in Medicine (SGUM). Results According to billing data, 49% of the GPs used ultrasound and provided 130,245 exams to 67,180 patients between 2004 and 2018. Over the years, ultrasound use became more frequent among GPs. Male GPs provide more ultrasound exams than female GPs. Patients that are female, ≥65 years, and multi-morbid had more ultrasound exams compared to males, patients <65 years, and those with only one morbidity, respectively. GPs provided a mean of 129 ultrasound exams per physician-year. Abdominal ultrasound comprised almost 69% of all exams. According to survey data, indications covered many organ systems and clinical conditions, with most POCUS indications being among them. Conclusions Utilization of ultrasound is high among general practitioners and covers a wide range of indications. A focus in certification on POCUS might reduce the variety of indications. Keywords: Ultrasound; general practice; primary care; general practitioners; clinical indications; POCUS; ultrasound certification; Switzerland


Diagnostics ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 363
Author(s):  
Vânia M. Moreira ◽  
Paulo Mascarenhas ◽  
Vanessa Machado ◽  
João Botelho ◽  
José João Mendes ◽  
...  

The rapid and accurate testing of SARS-CoV-2 infection is still crucial to mitigate, and eventually halt, the spread of this disease. Currently, nasopharyngeal swab (NPS) and oropharyngeal swab (OPS) are the recommended standard sampling techniques, yet, these have some limitations such as the complexity of collection. Hence, several other types of specimens that are easier to obtain are being tested as alternatives to nasal/throat swabs in nucleic acid assays for SARS-CoV-2 detection. This study aims to critically appraise and compare the clinical performance of RT-PCR tests using oral saliva, deep-throat saliva/posterior oropharyngeal saliva (DTS/POS), sputum, urine, feces, and tears/conjunctival swab (CS) against standard specimens (NPS, OPS, or a combination of both). In this systematic review and meta-analysis, five databases (PubMed, Scopus, Web of Science, ClinicalTrial.gov and NIPH Clinical Trial) were searched up to the 30th of December, 2020. Case-control and cohort studies on the detection of SARS-CoV-2 were included. The methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS 2). We identified 1560 entries, 33 of which (1.1%) met all required criteria and were included for the quantitative data analysis. Saliva presented the higher accuracy, 92.1% (95% CI: 70.0–98.3), with an estimated sensitivity of 83.9% (95% CI: 77.4–88.8) and specificity of 96.4% (95% CI: 89.5–98.8). DTS/POS samples had an overall accuracy of 79.7% (95% CI: 43.3–95.3), with an estimated sensitivity of 90.1% (95% CI: 83.3–96.9) and specificity of 63.1% (95% CI: 36.8–89.3). The remaining index specimens could not be adequately assessed given the lack of studies available. Our meta-analysis shows that saliva samples from the oral region provide a high sensitivity and specificity; therefore, these appear to be the best candidates for alternative specimens to NPS/OPS in SARS-CoV-2 detection, with suitable protocols for swab-free sample collection to be determined and validated in the future. The distinction between oral and extra-oral salivary samples will be crucial, since DTS/POS samples may induce a higher rate of false positives. Urine, feces, tears/CS and sputum seem unreliable for diagnosis. Saliva testing may increase testing capacity, ultimately promoting the implementation of truly deployable COVID-19 tests, which could either work at the point-of-care (e.g. hospitals, clinics) or at outbreak control spots (e.g., schools, airports, and nursing homes).


Cureus ◽  
2019 ◽  
Author(s):  
Madeline Schwid ◽  
Owen Harris ◽  
Adaira Landry ◽  
Andrew Eyre ◽  
Patricia Henwood ◽  
...  

Author(s):  
Zhijia Peng ◽  
Xiaogang Lin ◽  
Weiqi Nian ◽  
Xiaodong Zheng ◽  
Jayne Wu

Early diagnosis and treatment have always been highly desired in the fight against cancer, and detection of circulating tumor DNA (ctDNA) has recently been touted as highly promising for early cancer screening. Consequently, the detection of ctDNA in liquid biopsy gains much attention in the field of tumor diagnosis and treatment, which has also attracted research interest from the industry. However, traditional gene detection technology is difficult to achieve low cost, real-time and portable measurement of ctDNA. Electroanalytical biosensors have many unique advantages such as high sensitivity, high specificity, low cost and good portability. Therefore, this review aims to discuss the latest development of biosensors for minimal-invasive, rapid, and real-time ctDNA detection. Various ctDNA sensors are reviewed with respect to their choices of receptor probes, detection strategies and figures of merit. Aiming at the portable, real-time and non-destructive characteristics of biosensors, we analyze their development in the Internet of Things, point-of-care testing, big data and big health.


2017 ◽  
Vol 45 (7) ◽  
pp. 408-415 ◽  
Author(s):  
Whitney Hansen ◽  
Carl E. Mitchell ◽  
Bikash Bhattarai ◽  
Napatkamon Ayutyanont ◽  
Jeffrey R. Stowell

Sign in / Sign up

Export Citation Format

Share Document