scholarly journals Characterization of the interatrial septum by high-field cardiac MRI: a comparison with multi-slice computed tomography

2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Abdalla Elagha ◽  
Yaseen Othman ◽  
Reham Darweesh ◽  
Ghada Awadein ◽  
Assem Hashad

Abstract Background Assessment of the interatrial septum (IAS) has become an attractive area of interest for a variety of important interventional procedures. Newer imaging modalities like multi-slice computed tomography (MSCT) and cardiac MRI (CMR) can provide higher resolution and wider field of view than echocardiography. Moreover, high-field (3-Tesla) CMR can even enhance spatial and temporal resolution. The characteristics of the interatrial septum were retrospectively studied in 371 consecutive subjects (201 men, 31–73 years old) in whom MSCT was performed primarily for non-invasive evaluation of the coronary arteries. All subjects underwent both MSCT and MRI scans within 0–30 day’s interval. A 3D volume covering the whole heart was acquired across the heart with and without contrast enhancement. Also, patients underwent cardiac MSCT examinations using 64-row MSCT scanners. Results The mean scan time of MSCT was 10.4 ± 2.8 s and 9.7 ± 2.9 min for CMR. The mean length of IAS by CMR and CT was 39.65 ± 4.6 mm and 39.28 ± 4.7 mm, respectively. The mean maximal thickness of IAS by CMR and CT was 3.1 ± 0.97 mm and 3.15 ± 0.95 mm, respectively. The mean thickness of fossa ovalis by CMR and CT was 1.04 ± 0.36 mm and 1.04 ± 0.44 mm, respectively. The mean length of fossa ovalis by CMR and CT was 12.8 ± 3.7 mm and 12.8 ± 3.5 mm, respectively. Finally, the mean angle of IAS by CMR and CT was identical (155 ± 9.2°). Measurements of various morphological features of IAS showed no statistically significant difference between CMR and CT, with an excellent correlation and close relationship regarding IAS length, maximal IAS thickness, fossa ovalis thickness, fossa ovalis length, and IAS angle (r = 0.98, 0.98, 0.95, 0.96, and 0.92, respectively). Conclusion Whole-heart 3D acquisition at 3-T MRI using a free-breathing technique provides a valuable non-invasive imaging tool for excellent assessment of the interatrial septum—as compared to MSCT—that may have significant clinical implication for diagnostic purposes and therapeutic interventional procedures, as it may facilitate planning, improve outcome, and shorten its duration.

2018 ◽  
Vol 6 (8) ◽  
pp. 232596711879074 ◽  
Author(s):  
Robert C. Spang ◽  
Daniel B. Haber ◽  
Brendin R. Beaulieu-Jones ◽  
Kristen L. Stupay ◽  
George Sanchez ◽  
...  

Background: Jones fractures result in subsequent dysfunction and remain an issue for athletes. Purpose: To (1) describe the epidemiology, treatment, and impact of Jones fractures identified at the National Football League (NFL) Scouting Combine on players’ early careers and (2) establish the value of computed tomography (CT) to determine bony healing after a fracture in prospective players. Study Design: Cohort study; Level of evidence, 3. Methods: All players who attended the combine between 2009 and 2015 were retrospectively reviewed to identify their history of Jones fractures. The playing position, treatment method, and number of missed collegiate games were recorded. The mean overall draft pick number, number of games started and played, snap percentage, and position-specific performance scores (fantasy score) over the first 2 years in the NFL were compared between players with fractures and controls. An imaging classification system was applied based on grading of each quadrant of the fifth metatarsal (plantar, dorsal, medial, lateral), with a score of 0 for not healed or 1 for healed. Results: Overall, the number of Jones fractures identified was 72 in 2285 athletes (3.2%), with all treated via intramedullary screw fixation. The mean overall draft pick number for players with fractures was 111.2 ± 67.9 compared with 99.0 ± 65.9 for controls ( P = .12). Performance scores for players with fractures were lower than those for controls across all positions, with a significant difference in running backs (2.6 vs 4.0, respectively; P < .001) and defensive linemen (1.4 vs 2.3, respectively; P = .02). The mean CT score was 2.5 ± 1.3. Of the 32 athletes who underwent imaging, 16 Jones fractures (50.0%) were healed or nearly healed, 12 (37.5%) were partially healed, and 4 (12.5%) showed little or no healing. The plantar cortex demonstrated the least healing (18/32; 56.3%), followed by the lateral cortex (15/32; 46.9%). Players with a mean score <1 were found to have fewer games started (2.7 ± 2.5) than those with 1 to 3 cortices healed (17.4 ± 10.4) or all cortices healed (8.7 ± 11.2). Conclusion: Based on CT, 50% of all players with a previous Jones fracture demonstrated incomplete healing. Moreover, position-specific performance scores over the first 2 years of a player’s career were lower across all positions for those with fractures compared with controls. Players with CT scores <1 were found to start fewer games and were drafted later than controls.


2021 ◽  
Vol 7 (2) ◽  
Author(s):  
Atefeh Khavid ◽  
Mojgan Sametzadeh ◽  
Mostafa Godiny ◽  
Mohammad Mehdi Moarrefpour

Background and objective: In recent years, cone-beam computed tomography (CBCT) has become a key diagnostic tool in dentistry. CBCT can provide 3D images of the maxillofacial area to help dental practitioners in diagnosis and treatment, especially implant placement and treatment of pathogenic lesions. This study aimed to compare the Hounsfield Unit (HU) values obtained from CBCT images for bones of different densities with the corresponding HU values from MDCT images. Materials and methods: cube-shaped bone blocks of identical size were cut from the middle section of the cow ribs and femur area such that they had a layer of cortical bone in their buccal, lingual, and top surfaces and trabecular bone in the middle. MDCT scans were performed using a Somatom Sensation Ct Scanner. After determining HU from the results of these scans, nine suitable specimens from different ranges of HU were chosen for comparison. HU of the CBCT images was computed by the dedicated software of the CBCT machine. Finally, HU values obtained from MDCT and CBCT were compared. Data analysis was performed using SPSS version 25 at the 0.05 significance level. Results: The results showed a statistically significant difference between the mean HU from MDCT images and the mean HU from CBCT images (P<0.05). For similar specimens, CBCT produced higher mean HU values than MDCT. The Pearson correlation test detected a significant direct relationship between the HU values of specimens in MDCT and CBCT (P<0.05). Conclusion: For the tools and software used in this study, there was no significant difference between the HU values obtained from MDCT and CBCT, but the mean HU obtained from CBCT was higher than that from MDCT.


2018 ◽  
Vol 11 (4) ◽  
pp. 273-277
Author(s):  
Guilherme dos Santos Trento ◽  
Lucas Borin Moura ◽  
Rubens Spin-Neto ◽  
Philipp Christian Jürgens ◽  
Marisa Aparecida Cabrini Gabrielli ◽  
...  

The interest about upper airway evaluation has increased lately. Therefore, many softwares have been developed aiming to improve and facilitate the analysis of airway volume. The objective of this study was to compare two different softwares packages, Mimics and Dolphin, in their accuracy and precision in upper airway space measurements. Preoperative cone beam computed tomography scans of nine nonsyndromic patients submitted to surgically assisted rapid maxillary expansion were included in this study. The imaging exams were converted to DICOM (digital imaging and communications in medicine) files and imported to the softwares. The mean volume for the Dolphin group (G1) was 10.791 cm3 (SD = 4.269 cm3) and for the Mimics group (G2) was 10.553 cm3 (SD = 4.564 cm3). There was no statistically significant difference between the two groups ( p = 0.105).


2014 ◽  
Vol 2 (4) ◽  
Author(s):  
Kakale SB ◽  
Tabari AM ◽  
Isyaku K ◽  
Yunusa A

Ultrasound is a non-invasive, cheap and readily available imaging modality for studying the infant hip. Early detection of developmental hip subluxation, acetabular dysplasia and the prevention of late presentation of a developmentally dislocated hip with consequent secondary premature degenerative arthritis are goals that all practitioners should strive for. Provision of axial indices of alpha and beta angles of the infant hip joint in Kano, Nigeria using ultrasonography to establish a normogram as reference values for further studies is the objective of this study. This descriptive prospective study was conducted at the Radiology Department of Aminu Kano Teaching Hospital, Kano state, Nigeria. Successive four hundred appropriately consented infants were recruited for this study. The axial angle relationships of both hip joints were measured using 7.5 MHz linear transducer of Mindray DP-8800 Digital plus ultrasound machine. The mean alpha and beta angles for both hips in females were 56.590 and 49.580 respectively while those for males were 56.730 and 50.530 respectively. Minimum and maximum alpha angle for both hips ranged from 380 to 780 while the beta angles ranged 290 to 660 respectively. The age group 1-3 months has the highest frequency of respondents (251) while age group 10 - 12 months has the lowest (22). There was no statistically significant difference in the alpha and beta angles between males and females hips and age of the infants did not affect the hip indices. The study showed no statistical significant difference in the measured alpha and beta angles between males and females. Age of measurement in infants did not affect the hip indices.


2019 ◽  
Vol 9 (1Feb) ◽  
Author(s):  
R Ghanbarnezhad Farshi ◽  
A Mesbahi ◽  
M Johari ◽  
Ü Kara ◽  
N Gharehaghaji

Background: While the benefits of cone-beam computed tomography (CBCT) are well known in maxillofacial imaging, the use of this modality is not risk-free.Objective: The aim of this study was to evaluate the exposure doses received by patients during maxillofacial imaging with CBCT.Methods: Entrance surface dose (ESD) was measured by using thermoluminescent dosimeters (TLDs) attached to the eyes lids, parotid glands and thyroid of 64 patients in two imaging centers (A and B). Phantom dosimetry was performed by a cylindrical poly-methyl methacrylate (PMMA) head-size phantom and an ionization chamber for different exposure parameters. NewTom VGi and Planmeca Promax 3D CBCT scanners were used at centers A and B, respectively.Results: The mean ESD of the eyes, parotid glands and thyroid were 2.57, 2.33 and 0.28 mGy in center A, 0.35, 2.11 and 0.37 mGy in center B, respectively. ESD of the eyes revealed a significant difference in two centers; in center B, it was 86.4% lower than center A. In the phantom dosimetry, the measured doses of NewTom VGi were 2.63 and 2.08 mGy, respectively by changing field of view (FOV) size from 8×8 cm2 (height × diameter) to 6×6 cm2. For Planmeca Promax 3D, it ranged from 0.98 to 3.24 mGy depending on exposure parameters.Conclusion: There is a wide range of radiation doses dependent on the units, patients and selected scan parameters. Inappropriate selection of exposure settings, especially FOV size, can seriously increase patient dose.


Author(s):  
Hatice Dilek Özcanoğlu ◽  
Berna Türkay ◽  
Neşe Kutlutürk Şahin ◽  
Zahide Özlem Ulubay ◽  
Ayşe Sevinç Revanlı ◽  
...  

Objective: In this retrospective study, we aimed to evaluate the compatibility of endotracheal tube (ETT) size used during surgery with tracheal diameter measured by computed tomography(CT) and classic formulas in children who underwent CT imaging preoperatively due to surgical indications. Methods: The study included preoperatively CT scanned, 0-3 year-old patients who were operated due to congenital heart diseases between June 1-October 1, 2018.Using the CT scans, transverse and anteroposterior tracheal diameters were measured from the subglottic level. As these diameters reflect the external diameter of the ETT, the inner diameter-which corresponds the ETT size-was calculated using a correction formula. Besides, Cole’s formula was used to calculate the ETT size for each child, and the tube sizes used during surgeries were obtained from anesthesia charts.ETT sizes were compared. Results: 43 patients (22 girls [51.2%],21 boys [48.8%]) were included.The mean age was 10.5±9.6 months. 18 patients (41.9%) had cyanotic, 25 patients (58.1%) had acyanotic heart disease.Mean corrected transverse and anteroposterior tracheal diameters at CT images were 4.35±0.69mm and 4.30±0.71 mm, respectively. The mean diameter calculated by Cole’s formula was 4.22±0.20 mm. The mean tube size used during surgeries was 4.37±0.60 mm. There was no statistically significant difference between the tube sizes used during the surgeries and the corrected transverse tracheal diameters from CT measurements (p>0.05). But the tube sizes used during the surgeries found significantly larger than the diameters obtained by Cole’s formula (p<0.05). Conclusion: In 0-3 years of age pediatric patients who undergo a congenital heart surgery,corrected tracheal transverse diameter measured by CT is more effective,reliable and less invasive than classic formulas for determining appropriate ETT size


Medicina ◽  
2021 ◽  
Vol 57 (8) ◽  
pp. 840
Author(s):  
Alexandra Dumitrescu ◽  
Maria-Alexandra Martu ◽  
Alexandru Nemtoi ◽  
Ana Sirghe ◽  
Liliana Chelaru ◽  
...  

Background and Objectives: Odontogenic sinusitis is a frequently underestimated pathology with fewer symptoms in patients with periapical lesions, periodontal disease, or iatrogenic foreign bodies in the maxillary sinus. The aim of our study was to determine the correlation between maxillary sinusitis and periapical lesions using cone-beam computed tomography (CBCT) imaging and histological and immunohistochemical investigations. Materials and Methods: A total of 1450 initial patients diagnosed with maxillary sinusitis in the Ear-Nose-Throat (ENT) Department, University of Medicine and Pharmacy “Grigore T. Popa” Iasi, Romania, were treated with anti-inflammatory drugs. Of these, 629 still had unresolved symptomatology and were later referred to the Dental Medicine departments for further investigations. Only 50 subjects with periapical lesions in the premolar/molar maxillary area were included in the present study. All the periapical lesions were observed on CBCT and classified using the Periapical Status Index (PSI) and the mean maxillary sinus mucosa thicknesses (MSMT). The enrolled patients underwent surgical procedures with the excision of periapical lesions. The excised samples were submitted to the histological and immunohistochemical investigations. Results: The 50 patients presented periapical lesions of their maxillary teeth in 328 dental units. There was a higher prevalence of periapical lesions in men than in women (chi-square test). We observed a significant difference between the mean MSMT of individuals with periapical lesions compared to those without (p < 0.01). Mean MSMT was 1.23 mm for teeth without periapical lesions and 3.95 mm for teeth with periapical lesions. The histopathological study identified 50% cases with periapical granulomas, 10% cases with periapical granulomas with cystic potential, and 40% cases as periapical cysts. Immunohistochemical stainings showed that CD4+ helper and CD8+ cytotoxic T lymphocytes, along with CD20+ B lymphocytes and CD68+ macrophages, were diffusely distributed in all periapical cysts and in some periapical granulomas, but CD79α+ plasma cells characterized especially periapical granulomas. Conclusions: The current study observed a significant correlation between CBCT maxillary mucosa thickness and type of periapical lesion. Chronic inflammatory lympho-histiocytic infiltrate predominates in periapical lesions, supporting the idea that lesion progression is determined by a humoral-type (CD20+ and CD79α+ B lymphocytes) but also by a cellular-type (CD4+ and CD8+ T lymphocyte population) immune mechanism.


2020 ◽  
Author(s):  
Jae Youn Yoon ◽  
Soong Joon Lee ◽  
Kang Sup Yoon ◽  
Pil Whan Yoon

Abstract Backgrounds One of the most significant complications after a femoral neck fracture is osteonecrosis of the femoral head (ONFH). The concomitant use of single-photon emission computed tomography (SPECT) with computed tomography (CT) increases the sensitivity for detecting the anatomic location and severity of ONFH. In this study, we evaluated the diagnostic value of SPECT/CT for the occurrence of ONFH by quantifying the perfusion status of the femoral head. Methods A total of 30 patients who had multiple pinnings for femur neck fractures were included in this study. We classified the perfusion status into three groups: normal perfusion, decreased perfusion, and avascular groups, and compared the occurrence of femoral head necrosis between them. For quantitative analysis, we evaluated the uptake ratio of both femur heads (head-to-head uptake ratio). If the patient’s contralateral hip was incomparable, we measured the uptake ratio from the superior dome of the ipsilateral acetabulum (head-to-acetabulum uptake ratio). Results Twenty-four patients out of 30 achieved bone union, whereas the others developed ONFH. When the population was divided into intact and defective perfusion groups on scintigraphy, the sensitivity, specificity, and accuracy of the test were 83.3%, 75.0%, and 76.7%, respectively. The mean head-to-head uptake ratio value with a 95% confidence interval (CI) was 1.10 (95% CI: 0.85 – 1.36). In the osteonecrosis group, the mean value of the head-to-head uptake ratio was 0.33 (95% CI: 0.28 – 0.38). In contrast, the ratio was 1.30 (95% CI: 1.03 – 1.57) in the non-osteonecrosis group, demonstrating a significant difference in the uptake ratio ( P < 0.001). When the cutoff value of the uptake ratio was set to 0.5, both the sensitivity and specificity were 100%. There was also a significant difference in the head-to-acetabulum uptake ratio between the two groups ( P < 0.001). Conclusions SPECT/CT was useful in evaluating the perfusion status of the femoral head, showing high accuracy in predicting the occurrence of avascular necrosis. To demonstrate the reliability and validity of SPECT/CT, further prospective studies on a larger scale are warranted.


2020 ◽  
Author(s):  
Jae Youn Yoon ◽  
Soong Joon Lee ◽  
Kang Sup Yoon ◽  
Pil Whan Yoon

Abstract BackgroundsOne of the most significant complications after a femoral neck fracture is osteonecrosis of the femoral head (ONFH). The concomitant use of single-photon emission computed tomography (SPECT) with computed tomography (CT) increases the sensitivity for detecting the anatomic location and severity of ONFH. In this study, we evaluated the diagnostic value of SPECT/CT for the occurrence of ONFH by quantifying the perfusion status of the femoral head.MethodsA total of 30 patients who had multiple pinnings for femur neck fractures were included in this study. We classified the perfusion status into three groups: normal perfusion, decreased perfusion, and avascular groups, and compared the occurrence of femoral head necrosis between them. For quantitative analysis, we evaluated the uptake ratio of both femur heads (head-to-head uptake ratio). If the patient’s contralateral hip was incomparable, we measured the uptake ratio from the superior dome of the ipsilateral acetabulum (head-to-acetabulum uptake ratio).ResultsTwenty-four patients out of 30 achieved bone union, whereas the others developed ONFH. When the population was divided into intact and defective perfusion groups on scintigraphy, the sensitivity, specificity, and accuracy of the test were 83.3%, 75.0%, and 76.7%, respectively. The mean head-to-head uptake ratio value with a 95% confidence interval (CI) was 1.10 (95% CI: 0.85–1.36). In the osteonecrosis group, the mean value of the head-to-head uptake ratio was 0.33 (95% CI: 0.28–0.38). In contrast, the ratio was 1.30 (95% CI: 1.03–1.57) in the non-osteonecrosis group, demonstrating a significant difference in the uptake ratio (P < 0.001). When the cutoff value of the uptake ratio was set to 0.5, both the sensitivity and specificity were 100%. There was also a significant difference in the head-to-acetabulum uptake ratio between the two groups (P < 0.001).ConclusionsSPECT/CT was useful in evaluating the perfusion status of the femoral head, showing high accuracy in predicting the occurrence of avascular necrosis. To demonstrate the reliability and validity of SPECT/CT, further prospective studies on a larger scale are warranted.


2014 ◽  
Vol 39 (1) ◽  
pp. 85-89 ◽  
Author(s):  
K Cantekin ◽  
AE Şekerci

Objective: The aim of the present study was to clarify the occurrence, diameter, and location of the accessory mental foramen (AMF) using cone-beam computed tomography (CBCT) images from a sample of Turkish children. Study design: This retrospective was carried out using a total of 275 CBCT images from child and adolescent patients were randomly selected from existing records in the Department of Oral and Maxillofacial Radiology at the University of Erciyes, Kayseri, Turkey. The mental foramen (MF) and AMF were assessed on axial, sagittal, and coronal CBCT slices. Results: The mean age was 10.51 ± 3.32 years, consisting of 139 males (mean age 10.64 ± 3.42) and 126 females (mean age 10.38 ± 3.18). Twenty-one AMFs were observed in 18 of 275 patients (6.5%, 10 boys and eight girls). There was no significant difference in gender in relation to the prevalence of AMF (p = 0.65). The mean area of the 21 AMFs and the MF on the side with the AMF were 0.7 mm2 (SD ± 0.5) and 3.8 mm2 (SD ± 2.2), respectively. Conclusion: It is important to stress that detecting the AMN using CBCT with 3D reconstructions may reduce the risk of paralysis, hemorrhage, and postoperative pain in this region. Our study presents the first report assessing the occurrence, diameter, and location of the AMF in the pediatric population using CBCT images. In this respect, not surprisingly, the mean size of the AMF of our population is smaller than other reports in the literature that involve adult populations.


Sign in / Sign up

Export Citation Format

Share Document