Virtual brain tumor histopathology and immunohistochemistry with stimulated raman scattering microscopy.

2017 ◽  
Vol 35 (15_suppl) ◽  
pp. e13511-e13511
Author(s):  
Spencer B Lewis ◽  
Balaji Pandian ◽  
Todd Hollon ◽  
Yashar Niknafs ◽  
Mia Garrard ◽  
...  

e13511 Background: Stimulated Raman scattering (SRS) microscopy is a label-free optical technique which uses the chemical composition of fresh tissue to generate image contrast. Prior work has demonstrated exceptional correlation between SRS images and H&E microscopy for detecting brain tumor infiltration ex vivo. However, SRS has not previously been suitable for a clinical environment. Further, SRS has utilized structural, rather than chemical, diagnostic features. We present the first clinical validation of SRS, as well as our work towards mutation-targeted SRS imaging. Methods: Implementation of SRS with a fiber laser source allowed sufficient stability for clinical deployment. Unprocessed specimens from 200 neurosurgical cases were imaged at the CH2 and CH3 vibrational modes, then processed to mimic the appearance of H&E staining. 30 cases were trialed in a simulated intraoperative consultation to assess concordance between SRS and cryosection microscopy. A multi-layer perceptron (MLP) model was then used to predict brain tumor diagnosis based on quantified image attributes. To explore the potential for chemically specific SRS, isogenic lines of normal human astrocyte were prepared, differing by the presence or absence of the R132H mutation in the isocitrate dehydrogenase 1 (IDH1) gene. IDH1 R132H cells accumulate high concentrations of the oncometabolite 2-hydroxyglutarate and display predictably altered metabolism. 200 Raman spectra were collected from 50 wild type (WT) and 50 R132H cells with the aim of detecting these changes. Each cell line was then submitted for targeted metabolomic analysis. Results: Excellent concordance was observed between SRS and frozen section histology ( κ >0.89). The MLP diagnosed brain tumor subtype with 90% accuracy. A robust spectral difference was observed between wild type and R132H cells, which showed concordance with metabolomic data. Conclusions: The diagnostic capability, ease of use and speed of SRS make it well-suited for integration into the operative workflow. Further, because SRS amplifies the Raman signal with no resonant background, the spectral differences observed may allow rapid differentiation of IDH1 WT and R132H cells with SRS.

2017 ◽  
Vol 19 (suppl_4) ◽  
pp. iv51-iv51
Author(s):  
Todd Hollon ◽  
Mia Garrard ◽  
Jamaal Tarpeh ◽  
Balaji Pandian ◽  
Yashar Niknafs ◽  
...  

2016 ◽  
Vol 18 (suppl_6) ◽  
pp. vi193-vi193 ◽  
Author(s):  
Daniel A. Orringer ◽  
Balaji Pandian ◽  
Todd C. Hollon ◽  
Yashar S. Niknafs ◽  
Julianne Boyle ◽  
...  

Materials ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2266
Author(s):  
Dismas Choge ◽  
Huaixi Chen ◽  
Lei Guo ◽  
Guangwei Li ◽  
Wanguo Liang

In this study, simultaneous second-harmonic generation (SHG), sum frequency generation (SFG), and Raman conversion based on MgO-doped periodically poled lithium niobate (MgO:PPLN) for multi-wavelength generation is demonstrated. The approach used is based on a single MgO:PPLN crystal poled with a uniform period of 10.2 µm that phase matches SHG and SFG, simultaneously. Using a simplified double-pass geometry, up to 0.8 W of blue light at 487 nm is achieved by a frequency-doubling 974 nm laser diode pump, and 0.5 W of orange light at 598 nm is generated by frequency mixing 974 nm pump with C-band (1527–1565 nm) tunable laser source. At high pump powers of the 974 nm laser source, other unexpected peaks at 437, 536, 756, 815 and 1038 nm were observed, of which the 1038 nm line is due to Stimulated Raman Scattering within the MgO:PPLN crystal. The resulting multi-wavelength light source may find a wide range of applications in biomedicine and basic research.


2015 ◽  
Vol 1 (9) ◽  
pp. e1500738 ◽  
Author(s):  
Chien-Sheng Liao ◽  
Pu Wang ◽  
Ping Wang ◽  
Junjie Li ◽  
Hyeon Jeong Lee ◽  
...  

In vivo vibrational spectroscopic imaging is inhibited by relatively slow spectral acquisition on the second scale and low photon collection efficiency for a highly scattering system. Recently developed multiplex coherent anti-Stokes Raman scattering and stimulated Raman scattering techniques have improved the spectral acquisition time down to microsecond scale. These methods using a spectrometer setting are not suitable for turbid systems in which nearly all photons are scattered. We demonstrate vibrational imaging by spatial frequency multiplexing of incident photons and single photodiode detection of a stimulated Raman spectrum within 60 μs. Compared to the spectrometer setting, our method improved the photon collection efficiency by two orders of magnitude for highly scattering specimens. We demonstrated in vivo imaging of vitamin E distribution on mouse skin and in situ imaging of human breast cancerous tissues. The reported work opens new opportunities for spectroscopic imaging in a surgical room and for development of deep-tissue Raman spectroscopy toward molecular level diagnosis.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mandana Sadat Hosseini ◽  
Elnaz Yazdani ◽  
Batool Sajad

AbstractThis study reports the first experimental observation of cascaded stimulated Raman scattering (SRS) generation in a colloidal disordered medium. Generation of the cascaded effect requires both a high Raman gain and pump power in the disordered medium. Here, to extend effective path lengths of photons into the Raman gain medium for producing additional SRS processes, ZnO microspheres with abundant nano-protrusions as suitable scattering centers are proposed. It is explained that nano-protrusions on the surface of the spheres can act as nano reflectors and significantly provide potent feedback in the disordered system. This provided feedback via nano-protrusions boosts cascaded SRS generation to allow the appearance of higher Raman signals of Rhodamine 6G dye solution at a low scatterer concentration of 5 mg/ml. The threshold for the formation of the first Raman signal is measured at about 60 mJ/pulse. Also, the evolution of Raman signals under several fixed pump pulses is examined to investigate the stability from pulse to pulse. Our findings provide promising perspectives for achieving the single-frequency laser sources and generate desirable wavelengths for specific applications.


2014 ◽  
Vol 8 (2) ◽  
pp. 153-159 ◽  
Author(s):  
Christian W. Freudiger ◽  
Wenlong Yang ◽  
Gary R. Holtom ◽  
Nasser Peyghambarian ◽  
X. Sunney Xie ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document