The structural response of Submerged Floating Tunnel to multi-support seismic excitations

Author(s):  
S. J. Dyke ◽  
B. F. Spencer ◽  
M. K. Sain ◽  
J. D. Carlson

Abstract In this paper, the efficacy of magnetorheological (MR) dampers for seismic protection of structures is investigated through a series of experiments in which an MR damper is used to control a three story test structure subjected to a one-dimensional earthquake motion. Because of the intrinsic nonlinearity of the MR damper, several earthquake amplitudes are considered to investigate the performance, in terms of both peak and rms responses, of this control systems over a range of loading conditions. The results indicate that the MR damper is quite effective for structural response reduction over a wide class of seismic excitations.


2015 ◽  
Vol 665 ◽  
pp. 121-124 ◽  
Author(s):  
Robert Jankowski

Structural interactions between adjacent, insufficiently separated buildings have been repeatedly observed during damaging ground motions. This phenomenon, known as the structural pounding, may result in substantial damage or even total collapse of structures. The aim of the present paper is to show the results of the nonlinear numerical analysis focused on pounding between inelastic three-storey buildings under seismic excitations. The discrete lumped-mass numerical models of two building have been used in the analysis. The results of the study indicate that the response of the lighter and more flexible inelastic building can be substantially influenced by structural interactions, and collisions may even lead to the permanent deformation of the structure. On the other hand, the behaviour of the heavier and stiffer building does not really change considerably during the earthquake. The results of the study also indicate that incorporation of the inelastic behaviour of colliding buildings with different dynamic characteristics is very important for the purposes of accurate numerical modelling of pounding-involved structural response under damaging seismic excitations.


2018 ◽  
Vol 8 (12) ◽  
pp. 2386 ◽  
Author(s):  
Chungkuk Jin ◽  
Moo-Hyun Kim

Global dynamic analysis of a 700-m-long SFT section considered in the South Sea of Korea is carried out for survival random wave and seismic excitations. To solve the tunnel-mooring coupled hydro-elastic responses, in-house time-domain-simulation computer program is developed. The hydro-elastic equation of motion for the tunnel and mooring is based on rod-theory-based finite element formulation with Galerkin method with fully coupled full matrix. The dummy-connection-mass method is devised to conveniently connect objects and mooring lines with linear and rotational springs. Hydrodynamic forces on a submerged floating tunnel (SFT) are evaluated by the modified Morison equation for a moving object so that the hydrodynamic forces by wave or seismic excitations can be computed at its instantaneous positions at every time step. In the case of seabed earthquake, both the dynamic effect transferred through mooring lines and the seawater-fluctuation-induced seaquake effect are considered. For validation purposes, the hydro-elastic analysis results by the developed numerical simulation code is compared with those by a commercial program, OrcaFlex, which shows excellent agreement between them. For the given design condition, extreme storm waves cause higher hydro-elastic responses and mooring tensions than those of the severe seismic case.


Sign in / Sign up

Export Citation Format

Share Document