FE modeling of FRP strengthened RC joints

Author(s):  
S TalaeiTaba ◽  
D Mostofinejad
Keyword(s):  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Amin Mohamadi ◽  
Kaveh Momenzadeh ◽  
Aidin Masoudi ◽  
Kempland C. Walley ◽  
Kenny Ierardi ◽  
...  

Abstract Background Knowledge regarding the biomechanics of the meniscus has grown exponentially throughout the last four decades. Numerous studies have helped develop this knowledge, but these studies have varied widely in their approach to analyzing the meniscus. As one of the subcategories of mechanical phenomena Medical Subject Headings (MeSH) terms, mechanical stress was introduced in 1973. This study aims to provide an up-to-date chronological overview and highlights the evolutionary comprehension and understanding of meniscus biomechanics over the past forty years. Methods A literature review was conducted in April 2021 through PubMed. As a result, fifty-seven papers were chosen for this narrative review and divided into categories; Cadaveric, Finite element (FE) modeling, and Kinematic studies. Results Investigations in the 1970s and 1980s focused primarily on cadaveric biomechanics. These studies have generated the fundamental knowledge basis for the emergence of FE model studies in the 1990s. As FE model studies started to show comparable results to the gold standard cadaveric models in the 2000s, the need for understanding changes in tissue stress during various movements triggered the start of cadaveric and FE model studies on kinematics. Conclusion This study focuses on a chronological examination of studies on meniscus biomechanics in order to introduce concepts, theories, methods, and developments achieved over the past 40 years and also to identify the likely direction for future research. The biomechanics of intact meniscus and various types of meniscal tears has been broadly studied. Nevertheless, the biomechanics of meniscal tears, meniscectomy, or repairs in the knee with other concurrent problems such as torn cruciate ligaments or genu-valgum or genu-varum have not been extensively studied.


2021 ◽  
Vol 281 ◽  
pp. 122550
Author(s):  
Jiandong Huang ◽  
Massimo Losa ◽  
Pietro Leandri ◽  
Shiva G. Kumar ◽  
Junfei Zhang ◽  
...  
Keyword(s):  

2010 ◽  
Vol 48 (2) ◽  
pp. 349-359 ◽  
Author(s):  
M.A. Matin ◽  
D. Akai ◽  
N. Kawazu ◽  
M. Hanebuchi ◽  
K. Sawada ◽  
...  

2012 ◽  
Vol 26 (1) ◽  
pp. 233-243 ◽  
Author(s):  
D. Dias-da-Costa ◽  
J. Alfaiate ◽  
E.N.B.S. Júlio

Author(s):  
William J. Newman ◽  
Richard E. Debski ◽  
Susan M. Moore ◽  
Jeffrey A. Weiss

The shoulder is one of the most complex and often injured joints in the human body. The inferior glenohumeral ligament (IGHL), composed of the anterior band (AB), posterior band (PB) and the axillary pouch, has been shown to be an important contributor to anterior shoulder stability (Turkel, 1981). Injuries to the IGHL of the glenohumeral capsule are especially difficult to diagnose and treat effectively. The objective of this research was to develop a methodology for subject-specific finite element (FE) modeling of the ligamentous structures of the glenohumeral joint, specifically the IGHL, and to determine how changes in material properties affect predicted strains in the IGHL at 60° of external rotation. Using the techniques developed in this research, an improved understanding of the contribution of the IGHL to shoulder stability can be acquired.


2015 ◽  
Vol 137 (3) ◽  
Author(s):  
Yves Pauchard ◽  
Todor G. Ivanov ◽  
David D. McErlain ◽  
Jaques S. Milner ◽  
J. Robert Giffin ◽  
...  

High-tibial osteotomy (HTO) is a surgical technique aimed at shifting load away from one tibiofemoral compartment, in order the reduce pain and progression of osteoarthritis (OA). Various implants have been designed to stabilize the osteotomy and previous studies have been focused on determining primary stability (a global measure) that these designs provide. It has been shown that the local mechanical environment, characterized by bone strains and segment micromotion, is important in understanding healing and these data are not currently available. Finite element (FE) modeling was utilized to assess the local mechanical environment provided by three different fixation plate designs: short plate with spacer, long plate with spacer and long plate without spacer. Image-based FE models of the knee were constructed from healthy individuals (N = 5) with normal knee alignment. An HTO gap was virtually added without changing the knee alignment and HTO implants were inserted. Subsequently, the local mechanical environment, defined by bone compressive strain and wedge micromotion, was assessed. Furthermore, implant stresses were calculated. Values were computed under vertical compression in zero-degree knee extension with loads set at 1 and 2 times the subject-specific body weight (1 BW, 2 BW). All studied HTO implant designs provide an environment for successful healing at 1 BW and 2 BW loading. Implant von Mises stresses (99th percentile) were below 60 MPa in all experiments, below the material yield strength and significantly lower in long spacer plates. Volume fraction of high compressive strain ( > 3000 microstrain) was below 5% in all experiments and no significant difference between implants was detected. Maximum vertical micromotion between bone segments was below 200 μm in all experiments and significantly larger in the implant without a tooth. Differences between plate designs generally became apparent only at 2 BW loading. Results suggest that with compressive loading of 2 BW, long spacer plates experience the lowest implant stresses, and spacer plates (long or short) result in smaller wedge micromotion, potentially beneficial for healing. Values are sensitive to subject bone geometry, highlighting the need for subject-specific modeling. This study demonstrates the benefits of using image-based FE modeling and bone theory to fine-tune HTO implant design.


2008 ◽  
Vol 575-578 ◽  
pp. 367-372 ◽  
Author(s):  
L.G. Guo ◽  
He Yang

Nowadays, 3D-FE Modeling and simulation is an indispensable method for the optimum design and precise control of radial-axial ring rolling process for its complexities. In this paper, the unique forming characteristics of radial-axial ring rolling have first been summarized, and then some key technologies for 3D-FE modeling of the process have been presented and their solution schemes have been given out, lastly the modeling and simulation of radial-axial ring rolling process have been realized using elastic-plastic dynamic explicit procedure under ABAQUS environment. The work provides an important basis and platform for the future investigations, such as forming mechanism and laws, process optimum design and precise control.


Sign in / Sign up

Export Citation Format

Share Document