; Applied Hydraulic Transients: Automation and Advanced Control

2011 ◽  
Author(s):  
Fabricio Garelli ◽  
Ricardo J. Mantz ◽  
Hernán De Battista
Keyword(s):  

2000 ◽  
Vol 41 (4-5) ◽  
pp. 177-184 ◽  
Author(s):  
K.H. Sørensen ◽  
D. Thornberg ◽  
K.F. Janning

In 1998, the capacity of the BIOSTYR® submerged biofilter at Nyborg WWTP was extended from 48,000 PE to 60,000 PE including advanced sensor based control, post-denitrification in BIOSTYR® and equalization of side flows. The existing configuration with 8 BIOSTYR® DN/N cells is based on pre-denitrification and an internal recirculation of 600–800%. The extended plant comprises 7 BIOSTYR® DN/N cells with 50–225% recirculation followed by 3 BIOSTYR DN cells for post-denitrification. The advanced control loops include blower control, control of the number of active cells (stand-by), automatic switch to high load configuration, control of the side flow equalization, control of the internal recirculation and control of the external carbon source dosing. In this paper, the achieved improvements are documented by comparing influent and effluent data, methanol and energy consumption from comparable periods before and after the extension. Although the nitrogen load to the plant was increased by 20% after the extension, the effluent quality has improved significantly with a reduction of Total-N from 7–8 mg/l to 3–4 mg/l. Simultaneously, the methanol consumption has been reduced by more than 50% per kg removed nitrogen. The energy consumption remained constant although the nitrogen load was increased by 20% and the inflow by 80%.


Energies ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 3429 ◽  
Author(s):  
Chu ◽  
Yuan ◽  
Hu ◽  
Pan ◽  
Pan

With increasing size and flexibility of modern grid-connected wind turbines, advanced control algorithms are urgently needed, especially for multi-degree-of-freedom control of blade pitches and sizable rotor. However, complex dynamics of wind turbines are difficult to be modeled in a simplified state-space form for advanced control design considering stability. In this paper, grey-box parameter identification of critical mechanical models is systematically studied without excitation experiment, and applicabilities of different methods are compared from views of control design. Firstly, through mechanism analysis, the Hammerstein structure is adopted for mechanical-side modeling of wind turbines. Under closed-loop control across the whole wind speed range, structural identifiability of the drive-train model is analyzed in qualitation. Then, mutual information calculation among identified variables is used to quantitatively reveal the relationship between identification accuracy and variables’ relevance. Then, the methods such as subspace identification, recursive least square identification and optimal identification are compared for a two-mass model and tower model. At last, through the high-fidelity simulation demo of a 2 MW wind turbine in the GH Bladed software, multivariable datasets are produced for studying. The results show that the Hammerstein structure is effective for simplify the modeling process where closed-loop identification of a two-mass model without excitation experiment is feasible. Meanwhile, it is found that variables’ relevance has obvious influence on identification accuracy where mutual information is a good indicator. Higher mutual information often yields better accuracy. Additionally, three identification methods have diverse performance levels, showing their application potentials for different control design algorithms. In contrast, grey-box optimal parameter identification is the most promising for advanced control design considering stability, although its simplified representation of complex mechanical dynamics needs additional dynamic compensation which will be studied in future.


Sign in / Sign up

Export Citation Format

Share Document