Determinants of Carbon Dioxide Tension

2005 ◽  
pp. 69-100
Perfusion ◽  
2006 ◽  
Vol 21 (1) ◽  
pp. 21-26 ◽  
Author(s):  
Frode Kristiansen ◽  
Jan Olav Høgetveit ◽  
Thore H Pedersen

This paper presents the clinical testing of a new capno-graph designed to measure the carbon dioxide tension at the oxygenator exhaust outlet in cardiopulmonary bypass (CPB). During CPB, there is a need for reliable, accurate and instant estimates of the arterial blood CO2 tension (PaCO2) in the patient. Currently, the standard practice for measuring PaCO2 involves the manual collection of intermittent blood samples, followed by a separate analysis performed by a blood gas analyser. Probes for inline blood gas measurement exist, but they are expensive and, thus, unsuitable for routine use. A well-known method is to measure PexCO2, ie, the partial pressure of CO2 in the exhaust gas output from the oxygenator and use this as an indirect estimate for PaCO2. Based on a commercially available CO2 sensor circuit board, a laminar flow capnograph was developed. A standard sample line with integrated water trap was connected to the oxygenator exhaust port. Fifty patients were divided into six different groups with respect to oxygenator type and temperature range. Both arterial and venous blood gas samples were drawn from the CPB circuit at various temperatures. Alfa-stat corrected pCO2 values were obtained by running a linear regression for each group based on the arterial temperature and then correcting the PexCO2 accordingly. The accuracy of the six groups was found to be (±SD): ±4.3, ±4.8, ±5.7, ±1.0, ±3.7 and ±2.1%. These results suggest that oxygenator exhaust capnography is a simple, inexpensive and reliable method of estimating the PaCO2 in both adult and pediatric patients at all relevant temperatures.


1985 ◽  
Vol 5 (3) ◽  
pp. 113
Author(s):  
P. T. Cook ◽  
K. Bernstein ◽  
L. Gisselsson ◽  
L. Jacodsson ◽  
S. Ohrlander ◽  
...  

1960 ◽  
Vol 15 (4) ◽  
pp. 583-588 ◽  
Author(s):  
F. N. Craig ◽  
E. G. Cummings

Two men ran for 20 or 60 seconds while inhaling air, oxygen or 4% carbon dioxide. Inspired respiratory minute volume was determined for each breath. Ventilation increased suddenly in the first breath with minimal changes in end-expiratory carbon dioxide tension and respiratory exchange ratio to a rate that remained constant for 20 seconds before increasing further. The rate of carbon dioxide output was uniform during the first 20 seconds. A 12% grade did not increase ventilation or oxygen uptake during runs of 20 seconds, but in the first minute of recovery, ventilation was 64% greater than after level runs. Inhalation of oxygen inhibited ventilation by 24% in the 20-second periods before and after the end of a 60-second run. Inhalation of carbon dioxide begun at rest produced increments in ventilation and end-expiratory carbon dioxide tension that varied little during running and recovery. In the 20-second runs ventilation varied with speed but appeared independent of ultimate metabolic cost. Submitted on January 21, 1960


1980 ◽  
Vol 49 (5) ◽  
pp. 863-868 ◽  
Author(s):  
R. P. Adams ◽  
H. G. Welch

Six subjects rode a bicycle ergometer on three occasions breathing 17, 21, or 60% oxygen. In addition to rest and recovery periods, each subject worked for 10 min at 55% of maximal oxygen uptake (VO2 max) and then to exhaustion at approximately 90% VO2 max. Performance time, inspired and expired gas fractions, ventilation, and arterialized venous oxygen tension (PO2), carbon dioxide tension (PCO2), lactate, and pH were measured. VO2, carbon dioxide output, [H+]a, and [HCO3-]a were calculated. Performance times were longer in hyperoxia than in normoxia or hypoxia. However, VO2 was not different at exhaustion in normoxia compared with hypoxia or hyperoxia. During exercise, hypoxia was associated with increased lactate levels and decreased [H+]a, PCO2, and [HCO3-]a. The opposite trends were generally associated with hyperoxia. At exhaustion, [H+]a was not different under any inspired oxygen fraction. These results support the contention that oxygen is not limiting for exercise of this intensity and duration. The results also suggest that [H+] is a possible limiting factor and that the effect of oxygen on performance is perhaps related to control of [H+].


Cryobiology ◽  
1978 ◽  
Vol 15 (6) ◽  
pp. 715 ◽  
Author(s):  
Y. Kawashima ◽  
H. Yoshikawa ◽  
I. Kosugi ◽  
K. Okada ◽  
T. Kitagaki ◽  
...  