scholarly journals Preparation of High-Payload, Prolonged-Release Biodegradable Poly(lactic-co-glycolic acid)-Based Tacrolimus Microspheres Using the Single-Jet Electrospray Method

2016 ◽  
Vol 64 (2) ◽  
pp. 171-178 ◽  
Author(s):  
Shiva Pathak ◽  
Biki Gupta ◽  
Bijay Kumar Poudel ◽  
Tuan Hiep Tran ◽  
Shobha Regmi ◽  
...  
2021 ◽  
Author(s):  
Clara Guido ◽  
Mariangela Testini ◽  
Stefania D’Amone ◽  
Barbara Cortese ◽  
Maria Grano ◽  
...  

Capsid-like PGA nanoparticles (NPs) allow sustained cell transfection in 2D and 3D configurations.


1980 ◽  
Vol 3 (6) ◽  
pp. 354-357 ◽  
Author(s):  
L. Feenstra ◽  
B.W.C. Van Der Ven ◽  
F.E. Kohn ◽  
J. Feijen

Artificial eardrums made from biodegradable poly(D, L-lactic acid), poly(glycolic acid) and poly(ß-benzyl-L-aspartate-co-L-leucine) 50/50, and made from the microporous poly(tetrafluoroethylene) and bisphenol-A poly(carbonate) membranes were implanted into the ear and as a reference subcutaneously in rats. The implants were histologically examined for periods up to one year. From the biodegradable polymers studied the poly(ß-benzyl-L-aspartate-co-L-leucine) 50/50 evoked the least tissue reaction and the newly formed tympanic membranes are the best in terms of thickness and overall integrity. The microporous poly(tetrafluoroethylene) membrane can be considered as a valuable support for the formation of a reinforced tympanic membrane.


2011 ◽  
Vol 328-330 ◽  
pp. 658-661
Author(s):  
Singare Sekou ◽  
Shou Yan Zhong ◽  
Zhen Zhong Sun

In this papers, the authors described a rapid prototyping method to produce vascularized tissue such liver scaffold for tissue engineering applications. A scaffold with interconnected channel was designed using CAD environment. The data were transferred to a Polyjet 3D Printing machine (Eden 250, Object, Israel) to generate the models. Based on the 3D Printing model, a PDMS (polydimethyl-silicone) mould was created which can be used to cast the biodegradable poly (L-lactic-co-glycolic acid) (PLGA )material. The advantages and limitations of Rapid Prototyping (RP) techniques as well as the future direction of RP development in tissue engineering scaffold fabrication were reviewed.


2016 ◽  
Vol 46 (12) ◽  
pp. 2216-2222
Author(s):  
Tiago Barbalho Lima ◽  
Ivan Martinez Padua ◽  
Karina Kamachi Kobashigawa ◽  
Marcela Aldrovani ◽  
Flor Diana Yocoay Claros Chacaltana ◽  
...  

ABSTRACT: This study examined the efficacy of an intravitreal dexamethasone-loaded device for the control of postoperative ocular inflammation in dogs following phacoemulsification. Twenty dogs with bilateral mature senile cataracts were prepared for surgery using routine protocols. A biodegradable poly (lactic-co-glycolic acid) copolymer device was inserted through the pars plana into the vitreous chamber immediately before phacoemulsification (device group [DG], n=20). Following surgery, a conventional group (CG) received local and systemic steroids, mydriatics, and antibiotic therapy. The same treatment protocol was adopted in DG, except for steroids. All eyes were examined before surgery and at various times after phacoemulsification. Ultrasonography showed gradual device shrinkage, with only remnants remaining at postoperative day (POD) 60. Signs of uveitis were observed in 35% of the DG on POD 7, but by POD 14, 50% of eyes showed signs of uveitis and these eyes required local steroid therapy. The intraocular pressure (IOP) was higher in the DG than in the CG immediately after surgery. IOP did not differ on POD 7 and POD 14, but was lower during the late postoperative period (POD 30 to 90). Flare values were greater in the DG than in the CG immediately following surgery, but showed no subsequent differences. In summary, the intravitreal dexamethasone device did not adequately control intraocular inflammation in dogs undergoing phacoemulsification.


Sign in / Sign up

Export Citation Format

Share Document