scholarly journals Minimizing contrast media dose in CT pulmonary angiography with high-pitch technique

2020 ◽  
Vol 93 (1111) ◽  
pp. 20190995
Author(s):  
Hanan Alobeidi ◽  
Muhammed Alshamari ◽  
Jonas Widell ◽  
Tomas Eriksson ◽  
Mats Lidén

Objectives: To perform CT pulmonary angiography (CTPA) using a minimal amount of iodinated contrast media. Methods: 47 patients (25 females) with mean age 69 years (range 41–82 years) referred for contrast-enhanced chest CT were prospectively included in this Phase IV clinical drug trial. All participants underwent a study specific CTPA in addition to the chest CT. The participants received 80 mg I/kg body weight Iohexol contrast media using a preparatory saline bolus, a dual flow contrast/saline bolus and a saline flush, and a scanner protocol with 80 kVp dual source high-pitch mode. Three readers independently assessed the image quality on the 3-point scale non-diagnostic, adequate or good-excellent image quality. Additionally, the pulmonary arterial contrast opacification was measured. Results: On average, the patients received 16.8 ml Iohexol 350 mg I/mL (range 12–20 ml). Mean patient weight was 71 kg (range 50–85 kg). Identically for all readers, pulmonary embolism (PE) was detected in 1/47 participants. The median number of examinations visually scored concerning pulmonary embolism as good–excellent was 47/47 (range 44–47); adequate 0/47 (0–3) and non-diagnostic 0/47 (range 0–0). The proportion adequate or better examinations was for all readers 47/47, 100% [95% confidence interval 92–100%]. The mean attenuation ± standard deviation in the pulmonary trunk was 325 ± 72 Hounsfield unit (range 165–531 Hounsfield unit). Conclusions: Diagnostic CTPA with 17 ml contrast media is possible in non-obese patients using low kVp, high pitch and carefully designed contrast media administration. Advances in knowledge: By combining several procedures in a CTPA protocol, the contrast media dose can be minimized.

Author(s):  
Sultan Aldosari ◽  
Zhonghua Sun

Background: The aim of this study is to perform a systematic review of the feasibility and clinical application of double low-dose CT pulmonary angiography (CTPA) in the diagnosis of patients with suspected pulmonary embolism. Discussion: A total of 13 studies were found to meet selection criteria reporting both low radiation dose (70 or 80 kVp versus 100 or 120 kVp) and low contrast medium dose CTPA protocols. Lowdose CTPA resulted in radiation dose reduction from 29.6% to 87.5% in 12 studies (range: 0.4 to 23.5 mSv), while in one study, radiation dose was increased in the dual-energy CT group when compared to the standard 120 kVp group. CTPA with use of low contrast medium volume (range: 20 to 75 ml) was compared to standard CTPA (range: 50 to 101 ml) in 12 studies with reduction between 25 and 67%, while in the remaining study, low iodine concentration was used with 23% dose reduction achieved. Quantitative assessment of image quality (in terms of signal-to-noise ratio and contrast-to-noise ratio) showed that low-dose CTPA was associated with higher, lower and no change in image quality in 3, 3 and 6 studies, respectively when compared to the standard CTPA protocol. The subjective assessment indicated similar image quality in 11 studies between low-dose and standard CTPA groups, and improved image quality in 1 study with low-dose CTPA. Conclusion: This review shows that double low-dose CTPA is feasible in the diagnosis of pulmonary embolism with significant reductions in both radiation and contrast medium doses, without compromising diagnostic image quality.


2021 ◽  
Vol 11 (5) ◽  
pp. 1817-1827
Author(s):  
Bernhard Petritsch ◽  
Pauline Pannenbecker ◽  
Andreas M. Weng ◽  
Jan-Peter Grunz ◽  
Simon Veldhoen ◽  
...  

2012 ◽  
Vol 53 (1) ◽  
pp. 69-75 ◽  
Author(s):  
Stefan Bulla ◽  
Gregor Pache ◽  
Thorsten Bley ◽  
Mathias Langer ◽  
Philipp Blanke

Background Computed tomography pulmonary angiography (CTPA) has evolved as the gold standard for diagnosing pulmonary embolism. However, subsegmental arteries are often not assessed to do insufficient attenuation. Purpose To evaluate the influence of simultaneous bilateral versus unilateral injection of a fixed amount of contrast media on pulmonary artery opacification and image quality in CTPA. Material and Methods In this institutional review board-approved prospective study, 180 patients (91 women, mean age 61.9 ± 16.5 years) referred for CTPA (100 kV) due to suspected pulmonary embolism were randomized in groups of 45 patients each, with either unilateral (A:4 mL/s; B:6 mL/s) or bilateral (C: 6 mL/s; D: 8 mL/s) (Y-shaped line) injection of 50 mL contrast media. Attenuation was assessed including the subsegmental arteries (4th order). Image quality was evaluated by two readers in consensus using a three-point grading scale (3 = excellent image quality, no artifacts, 1 = non-diagnostic). Results Mean pulmonary artery attenuation was significantly higher with bilateral injection (1st to 3rd order: A: 303.6 ± 8.8HU; B: 371.1 ± 11.0HU vs. C: 443.2 ± 24.1HU; D: 562.3 ± 15.3HU, P < 0.001). Evaluation of subsegmental arteries was feasible for all patients in groups B–D, but only in 36/45 (80%) patients in group A. Subsegmental attenuation was significantly higher with bilateral injection (A: 284.7 ± 12.1HU; B: 367.4 ± 12.1HU vs. C: 494.2 ± 21.5HU; D: 562.3 ± 26.7HU, P < 0.001). Image quality was diagnostic for all patients but best for group C (A: 2.15 ± 0.4; B: 2.14 ± 0.5; C: 2.92 ± 0.3, and D: 2.51 ± 0.5). Conclusion Using the same amount of contrast media, bilateral injection yields higher pulmonary artery attenuation and better image quality than unilateral injection. This technique may improve subsegmental pulmonary artery assessment.


Author(s):  
Mohamed Hossameldin khalifa ◽  
Ahmed Samir ◽  
Ayman Ibrahim Baess ◽  
Sara Samy Hendawi

Abstract Background Vascular angiopathy is suggested to be the major cause of silent hypoxia among COVID-19 patients without severe parenchymal involvement. However, pulmonologists and clinicians in intensive care units become confused when they encounter acute respiratory deterioration with neither severe parenchymal lung involvement nor acute pulmonary embolism. Other radiological vascular signs might solve this confusion. This study investigated other indirect vascular angiopathy signs on CT pulmonary angiography (CTPA) and involved a novel statistical analysis that was performed to determine the significance of associations between these signs and the CT opacity score of the pathological lung volume, which is calculated by an artificial intelligence system. Results The study was conducted retrospectively, during September and October 2020, on 73 patients with critical COVID-19 who were admitted to the ICU with progressive dyspnea and low O2 saturation on room air (PaO2 < 93%). They included 53 males and 20 females (73%:27%), and their age ranged from 18 to 88 years (mean ± SD=53.3 ± 13.5). CT-pulmonary angiography was performed for all patients, and an artificial intelligence system was utilized to quantitatively assess the diseased lung volume. The radiological data were analyzed by three expert consultant radiologists to reach consensus. A low CT opacity score (≤10) was found in 18 patients (24.7%), while a high CT opacity score (>10) was found in 55 patients (75.3%). Pulmonary embolism was found in 24 patients (32.9%); three of them had low CT opacity scores. Four other indirect vasculopathy CTPA signs were identified: (1) pulmonary vascular enlargement (57 patients—78.1%), (2) pulmonary hypertension (14 patients—19.2%), (3) vascular tree-in-bud pattern (10 patients—13.7%), and (4) pulmonary infarction (three patients—4.1%). There were no significant associations between these signs and the CT opacity score (0.3205–0.7551, all >0.05). Furthermore, both pulmonary vascular enlargement and the vascular tree-in-bud sign were found in patients without pulmonary embolism and low CT-severity scores (13/15–86.7% and 2/15–13.3%, respectively). Conclusion Pulmonary vascular enlargement or, less commonly, vascular tree-in-bud pattern are both indirect vascular angiopathy signs on CTPA that can explain the respiratory deterioration which complicates COVID-19 in the absence of severe parenchymal involvement or acute pulmonary embolism.


Author(s):  
Aya Yassin ◽  
Maryam Ali Abdelkader ◽  
Rehab M. Mohammed ◽  
Ahmed M. Osman

Abstract Background Pulmonary embolism (PE) is one of the known sequels of COVID-19 infection. We aimed to assess the incidence of PE in patients with COVID-19 infection and to evaluate the relationship between the CT severity of the disease and the laboratory indicators. This was a retrospective study conducted on 96 patients with COVID-19 infection proved by positive PCR who underwent CT pulmonary angiography (CTPA) with a calculation of the CT severity of COVID-19 infection. Available patients’ complaint and laboratory data at the time of CTPA were correlated with PE presence and disease severity. Results Forty patients (41.7%) showed positive PE with the median time for the incidence of PE which was 12 days after onset of the disease. No significant correlation was found between the incidence of PE and the patients’ age, sex, laboratory results, and the CT severity of COVID-19. A statistically significant relation was found between the incidence of PE and the patients’ desaturation, hemoptysis, and chest pain. A highly significant correlation was found between the incidence of PE and the rising in the D-dimer level as well as the progressive CT findings when compared to the previous one. Conclusion CT progression and the rising in D-dimer level are considered the most important parameters suggesting underlying PE in patients with positive COVID-19 infection which is commonly seen during the second week of infection and alert the use of CT pulmonary angiography to exclude or confirm PE. This is may help in improving the management of COVID-19 infection.


Sign in / Sign up

Export Citation Format

Share Document