Experimental Research on the Load-Bearing Capacity of Partially Encased Steel Columns Under Fire Conditions

2012 ◽  
Vol 3 (1) ◽  
pp. 81-94 ◽  
Author(s):  
António Correia ◽  
João Rodrigues ◽  
Manfred Korzen
Author(s):  
Mohammad Reza Ghaemdoust ◽  
Omid Yousefi ◽  
Kambiz Narmashiri ◽  
Masoumeh Karimian

In view of development and repair costs, support of structures is imperative. Several factors, for example, design and calculation errors, absence of appropriate installation, change of structures application, exhaustion, seismic tremor, fire and natural conditions diminish their strength. In such cases, structures have need of rehabilitation and restoration to achieve their original performance. One of the most up to date materials for retrofitting is carbon fiber reinforced polymer (CFRP) that can provide an amount of restriction to postpone buckling of thin steel walls. This paper provides a numerical and experimental investigation on CFRP strengthened short steel tubes with initial horizontal and vertical deficiency under compression. Ten square and circular specimens were tested to study effects of the following parameters: (1) position of deficiency, horizontal or vertical; (2) tube shape, square or circular; (3) CFRP strengthening. In the experiments, axial static loading was gradually applied and for the numerical study three-dimensional (3D) static nonlinear analysis method using ABAQUS software was performed. The results show that deficiency reduces load-bearing capacity of steel columns and the impact of horizontal deficiency is higher than the impact of vertical deficiency, in both square and circular tubes. Use of CFRP materials for strengthening of short steel columns with initial deficiency indicates that fibers play a considerable role on increasing load bearing capacity, reducing stress at the damage location, preventing deformation caused by deficiency and delaying local buckling. Both numerical and experimental outcomes are in good agreement, which underlines the accuracy of the models adopted.


2013 ◽  
Vol 351-352 ◽  
pp. 363-366
Author(s):  
Xi Kang Yan ◽  
Cheng Dong ◽  
Pei Chen ◽  
Kang Ma

In this paper,in order to study the load-bearing capacity of frame columns with construction joint under low-cyclic reversed loading, nine specimens were made, divided into three groups.Every group had three specimens, the first were made without construction joint, the second had fine processing construction joint, the third had simple processing construction joint. The three groups were loaded in axial compression ratio of 0.23,0.34,0.46 respectively.The results show that the influence of different processing with construction joint to crack position ultimate bearing capacity,skeleton curves.


Author(s):  
Anne K. Kawohl ◽  
Jörg Lange

Prior investigations of the load bearing capacity of bolts during fire have shown differing behaviour between bolts that were loaded by shear or by tensile loads. The interaction of the two loads has not yet been examined under fire conditions. This paper describes a preliminary test series on the post-fire performance of high-strength bolts of the property class 10.9 under combined tension and shear. The results show that how the bolt is loaded influences the load bearing capacity. It is assumed that this is also true at elevated temperatures. Further, atest set-up for experiments at elevated temperatures and a more detailed test series on the post-fire performance under combined tension and shear is presented.


Author(s):  
Araujo R. R. ◽  
Vellasco P. C. G. S. ◽  
Vellasco M. M. B. R. ◽  
Andrade S. A. L. ◽  
Lima L. R. O. ◽  
...  

2010 ◽  
Vol 16 (2) ◽  
pp. 230-236 ◽  
Author(s):  
C. Douglas Goode ◽  
Artiomas Kuranovas ◽  
Audronis Kazimieras Kvedaras

The paper presents the analysis of the experimental data of 1817 on concrete‐filled steel tubes ‐ CFSTs. These results are compared with the predicted results of the load‐bearing capacity of calculations of slender elements according to the methods suggested by Eurocode 4. The following types of tested CFSTs were analysed: circular and rectangular hollow section stub and long columns fully filled with concrete, which were with or without applied moments at the ends of specimen. During the results obtained in the result of the tests on the load bearing capacity for circular concrete‐filled steel tubular columns correspond with the calculated values based on methods presented by Eurocode 4. The experimental values of load bearing capacity for members of concrete‐filled rectangular hollow sections agree very well with the theoretical values where the concrete cylinder strength is below 75 N/mm2. The analysis demonstrated that preloading of concrete‐filled hollow section members does not influence the load bearing capacity. This paper also presents the examination of stress state distribution for concrete‐filled hollow section members, influence of concrete preloading and of longitudinal stress strain curves. Santrauka Straipsnyje aptariami 1817 betonšerdžiu plieniniu vamzdiniu strypu eksperimentiniai duomenys. Šie duomenys lyginami su rezultatais, gautais remiantis Eurocode 4 pateiktais kompozitiniu elementu laikomosios galios nustatymo metodais. Analizuojami tokie betonšerdžiu plieniniu strypu bandiniu tipai: pilnavidures trumpos arba liaunos apskritojo ir stačiakampio skerspjūvio vamzdines betonšerdes plienines kolonos su ju galuose veikiančiu lenkiamuoju momentu arba be jo. Apskritojo skerspjūvio betonšerdžiu kolonu bandymu metu gautieji laikomosios galios rezultatai atitinka remiantis Eurocode 4 pateiktais metodais apskaičiuotasias ju reikšmes. Stačiakampio skerspjūvio betonšerdžiu elementu laikomosios galios bandymais rastosios reikšmes labai gerai atitinka teorines reikšmes, kai šerdies betono ritininis stipris nesiekia 75 N/mm2. Analizuojant nustatyta, kad išankstinis betonšerdžiu elementu apkrovimas neturi beveik jokio poveikio elementu laikomajai galiai. Šiame straipsnyje taip pat nagrinejamas betonšerdžiu elementu itempiu būviu pasiskirstymas, betono apspaudimo poveikis bei išilginiu deformaciju ir itempiu kreives.


2014 ◽  
Vol 923 ◽  
pp. 93-96 ◽  
Author(s):  
Jiří Witzany ◽  
Radek Zigler

The experimental research of failure mechanism of stone columns made of coursed masonry of regular sandstone blocks and coursed masonry of irregular (freestone) blocks under concentric compression and the research of the performance of non-reinforced as well as CFRP-reinforced stone columns completed to-date pointed out the necessity of a different approach to the assessment of the load-bearing capacity, or residual load-bearing capacity, of masonry composed of stone blocks.


Sign in / Sign up

Export Citation Format

Share Document