scholarly journals Immediate Effect of Serratus Posterior Inferior Muscle Direction Taping on Thoracolumbar Junction Rotation Angle During One Arm Lifting in the Quadruped Position

2021 ◽  
Vol 28 (3) ◽  
pp. 227-234
Author(s):  
Nu-ri Kim ◽  
Sun-hee Ahn ◽  
Gyeong-tae Gwak ◽  
Hwa-ik Yoo ◽  
Oh-yun Kwon
Author(s):  
H. Hashimoto ◽  
Y. Sugimoto ◽  
Y. Takai ◽  
H. Endoh

As was demonstrated by the present authors that atomic structure of simple crystal can be photographed by the conventional 100 kV electron microscope adjusted at “aberration free focus (AFF)” condition. In order to operate the microscope at AFF condition effectively, highly stabilized electron beams with small energy spread and small beam divergence are necessary. In the present observation, a 120 kV electron microscope with LaB6 electron gun was used. The most of the images were taken with the direct electron optical magnification of 1.3 million times and then magnified photographically.1. Twist boundary of ZnSFig. 1 is the image of wurtzite single crystal with twist boundary grown on the surface of zinc crystal by the reaction of sulphur vapour of 1540 Torr at 500°C. Crystal surface is parallel to (00.1) plane and electron beam is incident along the axis normal to the crystal surface. In the twist boundary there is a dislocation net work between two perfect crystals with a certain rotation angle.


2009 ◽  
Author(s):  
Sue A. Ferguson ◽  
William S. Marras ◽  
W. Gary Allread ◽  
Gregory G. Knapik ◽  
Kimberly A. Vandlen ◽  
...  

2020 ◽  
pp. 1-9
Author(s):  
Ako Matsuhashi ◽  
Keisuke Takai ◽  
Makoto Taniguchi

OBJECTIVESpontaneous spinal CSF leaks are caused by abnormalities of the spinal dura mater. Although most cases are treated conservatively or with an epidural blood patch, some intractable cases require neurosurgical treatment. However, previous reports are limited to a small number of cases. Preoperative detection and localization of spinal dural defects are difficult, and surgical repair of these defects is technically challenging. The authors present the anatomical characteristics of dural defects and surgical techniques in treating spontaneous CSF leaks.METHODSAmong the consecutive patients who were diagnosed with spontaneous CSF leaks at the authors’ institution between 2010 and 2020, those who required neurosurgical treatment were included in the study. All patients’ clinical information, radiological studies, surgical notes, and outcomes were reviewed retrospectively. Outcomes of two different procedures in repairing dural defects were compared.RESULTSAmong 77 patients diagnosed with spontaneous CSF leaks, 21 patients (15 men; mean age 57 years) underwent neurosurgery. Dural defects were detected by FIESTA MRI in 7 patients, by CT myelography in 12, by digital subtraction myelography in 1, and by dynamic CT myelography in 1. The spinal levels of the defects were localized at the cervicothoracic junction in 16 patients (76%) and thoracolumbar junction in 4 (19%). Intraoperative findings revealed that the dural defects were small, circumscribed longitudinal slits located at the ventral aspect of the dura mater. The median dural defect size was 5 × 2 mm. The presence of dural defects at the thoracolumbar junction was associated with manifestation of an altered mental status, which was an unusual manifestation of CSF leaks (p = 0.003). Eight patients were treated via the posterior transdural approach with watertight primary sutures of the ventral defects, and 13 were treated with muscle or fat grafting. Regardless of the two different procedures, postoperative MRI showed either complete disappearance or significant reduction of the extradural CSF collection. No patient experienced postoperative neurological deficits. Clinical symptoms improved or stabilized in 20 patients with a median follow-up of 12 months.CONCLUSIONSDural defects in spontaneous CSF leaks were small, circumscribed longitudinal slits located ventral to the spinal cord at either the cervicothoracic or thoracolumbar junction. Muscle/fat grafting may be an alternative treatment to watertight primary sutures of ventral dural defects with a good outcome.


Polymers ◽  
2021 ◽  
Vol 13 (6) ◽  
pp. 971
Author(s):  
Young Soo Yu ◽  
Chi Bum Ahn ◽  
Kuk Hui Son ◽  
Jin Woo Lee

A trachea has a structure capable of responding to various movements such as rotation of the neck and relaxation/contraction of the conduit due to the mucous membrane and cartilage tissue. However, current reported tubular implanting structures are difficult to impelement as replacements for original trachea movements. Therefore, in this study, we developed a new trachea implant with similar anatomical structure and mechanical properties to native tissue using 3D printing technology and evaluated its performance. A 250 µm-thick layer composed of polycaprolactone (PCL) nanofibers was fabricated on a rotating beam using electrospinning technology, and a scaffold with C-shaped cartilage grooves that mimics the human airway structure was printed to enable reconstruction of cartilage outside the airway. A cartilage type scaffold had a highest rotational angle (254°) among them and it showed up to 2.8 times compared to human average neck rotation angle. The cartilage type showed a maximum elongation of 8 times higher than that of the bellows type and it showed the elongation of 3 times higher than that of cylinder type. In cartilage type scaffold, gelatin hydrogel printed on the outside of the scaffold was remain 22.2% under the condition where no hydrogel was left in other type scaffolds. In addition, after 2 days of breathing test, the amount of gelatin remaining inside the scaffold was more than twice that of other scaffolds. This novel trachea scaffold with hydrogel inside and outside of the structure was well-preserved under external flow and is expected to be advantageous for soft tissue reconstruction of the trachea.


Proceedings ◽  
2021 ◽  
Vol 68 (1) ◽  
pp. 13
Author(s):  
Yixuan Sun ◽  
Stephen Beeby

This paper presents the COMSOL simulations of magnetically coupled resonant wireless power transfer (WPT), using simplified coil models for embroidered planar two-coil and four-coil systems. The power transmission of both systems is studied and compared by varying the separation, rotation angle and misalignment distance at resonance (5 MHz). The frequency splitting occurs at short separations from both the two-coil and four-coil systems, resulting in lower power transmission. Therefore, the systems are driven from 4 MHz to 6 MHz to analyze the impact of frequency splitting at close separations. The results show that both systems had a peak efficiency over 90% after tuning to the proper frequency to overcome the frequency splitting phenomenon at close separations below 10 cm. The four-coil design achieved higher power efficiency at separations over 10 cm. The power efficiency of both systems decreased linearly when the axial misalignment was over 4 cm or the misalignment angle between receiver and transmitter was over 45 degrees.


2007 ◽  
Vol 21 (04) ◽  
pp. 225-236 ◽  
Author(s):  
P. LIMSUWAN ◽  
N. UDOMKAN ◽  
P. WINOTAI

In this report, Fe 3+ impurity ions present in green sapphire ( Al 2 O 3) were studied experimentally, by heating a light green sapphire in flowing oxygen atmosphere for 12 h from 1200, 1300, 1400, 1500 and 1600°C, respectively. Electron spin resonance (ESR) spectra in X-band (~9.45 GHz ) were recorded by mounting the crystal with the c-axis perpendicular (θ = 90°) to the magnetic field direction. The spectra were recorded and simulated by a numerical diagonalization of spin Hamiltonian matrix in the range from 0 to 180 degrees for every 15 degrees of rotation angle (φ). In our case, only the last two sets of peaks strongly depend on the rotation angle (φ), and each exhibits C 3 symmetry due to two magnetically inequivalent Fe 3+ sites in the corundum structure. For polycrystalline ESR spectra, seven main Fe 3+ ESR absorption peaks occur at the resonance magnetic fields of 100.20, 310.24, 486.80, 525.00, 550.60, 761.00 and 777.00 mT respectively. Specifically, ESR signals show that the number of paramagnetic Fe 3+ ions increase roughly linearly with the heat treating temperature, having the [Formula: see text] ratio ~1.41 at 1600°C.


Nanomaterials ◽  
2021 ◽  
Vol 11 (3) ◽  
pp. 586
Author(s):  
Chen-Yi Yu ◽  
Qiu-Chun Zeng ◽  
Chih-Jen Yu ◽  
Chien-Yuan Han ◽  
Chih-Ming Wang

In this study, the phase modulation ability of a dielectric Pancharatnam–Berry (PB) phase metasurface, consisting of nanofins, is theoretically analyzed. It is generally considered that the optical thickness of the unit cell of a PB-phase metasurface is λ/2, i.e., a half-waveplate for polarization conversion. It is found that the λ/2 is not essential for achieving a full 2π modulation. Nevertheless, a λ/2 thickness is still needed for a high polarization conversion efficiency. Moreover, a gradient phase metasurface is designed. With the help of the particle swarm optimization (PSO) method, the wavefront errors of the gradient phase metasurface are reduced by fine-tuning the rotation angle of the nanofins. The diffraction efficiency of the gradient phase metasurface is thus improved from 73.4% to 87.3%. This design rule can be utilized to optimize the efficiency of phase-type meta-devices, such as meta-deflectors and metalenses.


Sign in / Sign up

Export Citation Format

Share Document