scholarly journals Determination of ceftriaxone in human plasma using liquid chromatography–tandem mass spectrometry

2021 ◽  
Vol 4 ◽  
pp. 47
Author(s):  
Thamrong Wongchang ◽  
Markus Winterberg ◽  
Joel Tarning ◽  
Natthida Sriboonvorakul ◽  
Sant Muangnoicharoen ◽  
...  

Ceftriaxone is a cephalosporin antibiotic drug used as first-line treatment for a number of bacterial diseases. Ceftriaxone belongs to the third generation of antibiotics and is available as an intramuscular or intravenous injection. Previously published pharmacokinetic studies have used high-performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) for the quantification of ceftriaxone. This study aimed to develop and validate a bioanalytical method for the quantification of ceftriaxone in human plasma using liquid chromatography followed by tandem mass spectrometry (LC-MS/MS). Sample preparation was performed by protein precipitation of 100 µl plasma sample in combination with phospholipid-removal techniques to minimize matrix interferences. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C18 column with 10 mM ammonium formate containing 2% formic acid: acetonitrile as mobile phase at a flow rate of 0.4 ml/min with a total run time of 10 minutes. Both the analyte and cefotaxime (internal standard) were quantified using the positive electrospray ionization (ESI) mode and selected reaction monitoring (SRM) for the precursor-product ion transitions m/z 555.0→396.1 for ceftriaxone and 456.0→324.0 for cefotaxime. The method was validated over the concentration range of 1.01-200 μg/ml. Calibration response showed good linearity (correlation coefficient > 0.99) and matrix effects were within the ±15% limit in 6 different lots of sodium heparin plasma tested. However, citrate phosphate dextrose plasma resulted in a clear matrix enhancement of 24% at the low concentration level, which was not compensated for by the internal standard. Different anticoagulants (EDTA, heparin and citrate phosphate dextrose) also showed differences in recovery. Thus, it is important to use the same anticoagulant in calibration curves and clinical samples for analysis. The intra-assay and inter-assay precision were less than 5% and 10%, respectively, and therefore well within standard regulatory acceptance criterion of ±15%.

2019 ◽  
Vol 4 ◽  
pp. 47 ◽  
Author(s):  
Thamrong Wongchang ◽  
Markus Winterberg ◽  
Joel Tarning ◽  
Natthida Sriboonvorakul ◽  
Sant Muangnoicharoen ◽  
...  

Ceftriaxone is a cephalosporin antibiotic drug used as first-line treatment for several bacterial diseases. Ceftriaxone belongs to the third generation of antibiotics and is available as an intramuscular or intravenous injection. Previously published pharmacokinetic studies have mainly used high-performance liquid chromatography coupled with ultraviolet detection (HPLC-UV) for the quantification of ceftriaxone. This study aimed to develop and validate a bioanalytical method for the quantification of ceftriaxone in human plasma using liquid chromatography followed by tandem mass spectrometry (LC-MS/MS). Sample preparation was performed by protein precipitation in combination with phospholipid-removal techniques for cleaning up matrix interferences. The chromatographic separation was performed on an Agilent Zorbax Eclipse Plus C18 column with 10 mM ammonium formate containing 2% formic acid: acetonitrile as mobile phase at a flow rate of 0.4 ml/min. Both the analyte and cefotaxime (internal standard) were quantified using the positive electrospray ionization (ESI) mode and selected reaction monitoring (SRM) for the precursor-product ion transitions m/z 555.0→396.1 for ceftriaxone and 456.0→324.0 for cefotaxime. The method was validated over the concentration range of 1.01-200 μg/ml. Calibration response showed good linearity (correlation coefficient > 0.99) and no significant matrix effects were observed. The intra-assay and inter-assay precision were less than 5% and 10%, respectively, and therefore well within standard regulatory acceptance criterion of ±15%.


Author(s):  
Srikanth I ◽  
Prameela Rani A

Objective: This study was to develop and validate a liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the quantification of lenvatinib (LT) in human plasma.Methods: A simple, sensitive and specific LC–MS/MS method was developed for quantification of LT in human plasma using LTD4 as internal standard (IS). The analytical method consists of liquid–liquid extraction of plasma sample followed by the determination of LT by a LC–MS/MS. The analyte was separated on a Zorbax Eclipse XDB-C18 (150×4.6 mm, 5 μ) column with an isocratic mobile phase of acetontrile:0.1% formic acid (80:20 v/v) at a flow rate of 0.6 mL/minutes. The protonated ions were formed by a turbolon spray in a positive mode were used to detect analyte and IS. The MS/MS detection was made by monitoring the fragmentation of m/z 427.10→370.10 for LT and m/z 430.30→370.10 for IS on a MS.Result: The method was validated with the correlation coefficients of (r2) ≥0.995 over a linear concentration range of 10.20-501.60 pg/mL. This method demonstrated intra- and inter-day precision within 1.06-2.42% and 0.03-0.55% and accuracy within 95.64-100.08% and 97.16-100.07%.Conclusion: This method is suitable and convenient to pharmacokinetics and bioavailability studies for estimation of LT in biological samples by LC–MS/MS.


2018 ◽  
Vol 25 (4) ◽  
pp. 372-380 ◽  
Author(s):  
Sireesha Dodda ◽  
Ajitha Makula ◽  
Srinivasa R Polagani ◽  
Raj N Kandhagatla

A method for bioanalysis of pentoxifylline in human plasma was developed using liquid chromatography–tandem mass spectrometry, which is simple, specific, and sensitive. Pentoxifylline D5 was used as the internal standard. Employing only 100 µl of human plasma, processing was done with solid-phase extraction technique. The analyte and the internal standard were separated from endogenous components on Ace phenyl column using a mixture of 5 mM ammonium acetate buffer and high performance liquid chromatography grade acetonitrile (60:40, v/v) as mobile phase at a flow rate of 1 ml/min. The linearity of the method was in the range of 3–1200 ng/ml with r2 > 0.99. Positive ion MRM mode was used for the detection of the analyte and the internal standard. The method was validated as per the US Food and Drug Administration guidelines and the results were within the acceptance limits. The proposed method was applied for comparative pharmacokinetic study of pentoxifylline after oral administration of 400 and 600 mg tablets to South Indian male subjects under fed conditions.


2018 ◽  
Vol 62 (11) ◽  
Author(s):  
Carsten Müller ◽  
Cornelia Fietz ◽  
Philipp Koehler ◽  
Graham Sibley ◽  
Achu Che Awah Nforbugwe ◽  
...  

ABSTRACT A fast and easy-to-use liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination and quantification of a novel antifungal drug, olorofim (F901318), a member of the novel class of orotomides, in human plasma and serum was developed and validated. Sample preparation was based on protein precipitation with acetonitrile and subsequent centrifugation. An isotope-labeled analogue of F901318 was employed as an internal standard. Chromatographic separation was achieved using a 50-mm by 2.1-mm, 1.9-μm, polar Hypersil Gold C18 column and isocratic mobile phase consisting of 0.1% formic acid–acetonitrile (60%-40%, vol/vol) at a flow rate of 330 μl/min. The analyte was detected using a triple-stage quadrupole mass spectrometer operated in selected reaction monitoring (SRM) mode with positive heated electrospray ionization (HESI+) within a single runtime of 2.00 min. The present LC-MS/MS method was validated according to the international guidelines of the International Conference on Harmonisation (ICH) and the U.S. Food and Drug Administration (FDA). Linearity of F901318 concentration ranges was verified by the Mandel test. The calibration curve was tested linear across the range and fitted using least-squares regression with a weighting factor of the reciprocal concentration. The limit of detection was 0.0011 mg/liter, and the lower limit of quantitation was 0.0033 mg/liter. Intraday and interday precisions ranged from 1.17% to 3.23% for F901318, and intraday and interday accuracies (percent bias) ranged from 0.75% to 5.01%. In conclusion, a method was established for the rapid quantitation of F901318 concentrations in serum and plasma samples in patient trials, and it optimizes therapeutic drug monitoring in applying an easy-to-use single method.


2007 ◽  
Vol 21 (11) ◽  
pp. 1151-1158 ◽  
Author(s):  
Ramakrishna V. S. Nirogi ◽  
Vishwottam Kandikere ◽  
Wishu Shrivastava ◽  
Koteshwara Mudigonda ◽  
Santosh Maurya ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document