scholarly journals The Multi-source and Multi Operation Domain Coordinated Control Strategy of Power Grid

Author(s):  
Wei-chun GE ◽  
Qi-li HUANG ◽  
Jian-xin ZHU ◽  
Jian-guo WANG ◽  
Qun CHEN ◽  
...  
2015 ◽  
Vol 799-800 ◽  
pp. 1306-1310
Author(s):  
Fang Ming Niu ◽  
Peng Wang ◽  
Yu Cheng ◽  
Xue Dong Ren

The disadvantage of Beijing-Tianjin-Tangshan power grid operation control mode is that the control effect is poorer and the spare capacity demand is big, this paper puts forward a new coordinated control strategy. First of all, this paper describes the relationship between the load, frequency, the output of generating unit, the tie line power and the area control error relationship of the whole power grid, according to the regional automatic generation control performance assessment criteria, concludes the characteristics of regional unit adjustment. This paper analyzes the contradiction between them, and then proposes a coordinated control strategy between the Beijing-Tangshan power grid and Tianjin power grid. The case simulation results prove the superiority and feasibility of the new coordinated control strategy. Compared with the original, the new strategy reduces the volatility of the unit, shortens the recovery time of frequency, and has a certain practical significance.


Author(s):  
Fei Xia ◽  
Zongze Xia ◽  
Peixian Cong ◽  
Zhixiong Yang ◽  
Hanbiao Song ◽  
...  

2011 ◽  
Vol 12 ◽  
pp. 443-449
Author(s):  
Shanmei Liu ◽  
Lijie Ding ◽  
Yiqun Miao

2013 ◽  
Vol 732-733 ◽  
pp. 1157-1163
Author(s):  
Jia Zhang ◽  
Xiao Fang Song ◽  
Feng Xue

In the summer peak load operation mode of the interconnected power grid which is integrated with HVDC transmission lines from Central China power grid to East China power grid, security and stability emergency control strategies based on generator shedding and EDCPS (Emergency DC Power Support) are studied to cope with system instability caused by Tuanlin-Fengjing DC line unipolar block fault. Simulation results show that interconnected system cannot maintain the transient stability effectively by using EDCPS only. A coordinated control strategy which combines generator shedding with EDCPS is proposed to reduce the number of generators to be shed and ensure the transient stability. Through optimizing EDCPS which two or more HVDC lines participate in, an optimal coordinated control strategy is proposed. Simulation results present that the strategy which combines GC shedding with Longzheng DC bipolar supporting is the optimal strategy.


Author(s):  
Li Yunwei ◽  
Yujun Zhang ◽  
Hua Liu

Aiming at a wide range and high-frequency reactive voltage fluctuation problem in 750kV power grid which due to large-scale wind power, a coordinated control strategy of a multiple FACTS (Flexible Alternative Current Transmission Systems) configuration is investigated in the paper. System-level and electromagnetic transient level control method of multiple FACTS devices are proposed in the small wind power fluctuation, big disturbance and off-grid level, and the priorities and the principles are determined. The strategy is applied to “Xinjiang and Northwest 750kV main grid interconnection second channel project”, and the correctness and effectiveness is proved.


Sign in / Sign up

Export Citation Format

Share Document