Towards On-Chip Measurement of S-Parameters for Ultrasonic Guided-Wave SHM: Damage Localization in Aluminum Using S-Parameter Measurements

Author(s):  
GIFT NYIKAYARAMBA ◽  
BORIS MURMANN
Aerospace ◽  
2020 ◽  
Vol 7 (3) ◽  
pp. 33
Author(s):  
Gift Nyikayaramba ◽  
Boris Murmann

In this work, an approach for enabling miniaturized, low-voltage hardware for active structural health monitoring (SHM) based on ultrasonic guided waves is investigated. The proposed technique relies on S-parameter measurements instead of time-domain pulsing and thereby trades off longer measurement times with lower actuation voltages for improved compatibility with dense complementary metal-oxide-semiconductor (CMOS) chip integration. To demonstrate the feasibility of this method, we present results showing the successful localization of defects in aluminum and carbon-fiber-reinforced polymer (CFRP) test structures using S-parameter measurements. The S-parameter measurements were made on benchtop vector network analyzers that actuate the piezoelectric transducers at output voltage amplitudes as low as 1.264 Vpp.


2018 ◽  
Vol 10 (1) ◽  
Author(s):  
Guoyi Li

This Ph.D. research focuses on developing reliable and effective structural health monitoring and prognostic health management frameworks for complex structures and system. The ultrasonic guided wave is used as a robust interrogation tool for structural level monitoring; numerical simulation, sensing architecture, signal processing and damage localization technique are being developed. For system level management, data mining techniques, with high-fidelity simulation platform, are used to establish a reliable fault detection and prediction for in-air aircrafts.


Author(s):  
Keith Harber ◽  
Steve Brockett

Abstract This paper outlines the failure analysis of a Radio Frequency only (RF-only) failure on a complex Multimode Multiband Power Amplifier (MMPA) module, where slightly lower gain was observed in one mode of operation. 2 port S-parameter information was collected and utilized to help localize the circuitry causing the issue. A slight DC electrical difference was observed, and simulation was utilized to confirm that difference was causing the observed S-parameters. Physical analysis uncovered a very visible cause for the RF-only failure.


Nanophotonics ◽  
2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Ali Rostamian ◽  
Ehsan Madadi-Kandjani ◽  
Hamed Dalir ◽  
Volker J. Sorger ◽  
Ray T. Chen

Abstract Thanks to the unique molecular fingerprints in the mid-infrared spectral region, absorption spectroscopy in this regime has attracted widespread attention in recent years. Contrary to commercially available infrared spectrometers, which are limited by being bulky and cost-intensive, laboratory-on-chip infrared spectrometers can offer sensor advancements including raw sensing performance in addition to use such as enhanced portability. Several platforms have been proposed in the past for on-chip ethanol detection. However, selective sensing with high sensitivity at room temperature has remained a challenge. Here, we experimentally demonstrate an on-chip ethyl alcohol sensor based on a holey photonic crystal waveguide on silicon on insulator-based photonics sensing platform offering an enhanced photoabsorption thus improving sensitivity. This is achieved by designing and engineering an optical slow-light mode with a high group-index of n g  = 73 and a strong localization of modal power in analyte, enabled by the photonic crystal waveguide structure. This approach includes a codesign paradigm that uniquely features an increased effective path length traversed by the guided wave through the to-be-sensed gas analyte. This PIC-based lab-on-chip sensor is exemplary, spectrally designed to operate at the center wavelength of 3.4 μm to match the peak absorbance for ethanol. However, the slow-light enhancement concept is universal offering to cover a wide design-window and spectral ranges towards sensing a plurality of gas species. Using the holey photonic crystal waveguide, we demonstrate the capability of achieving parts per billion levels of gas detection precision. High sensitivity combined with tailorable spectral range along with a compact form-factor enables a new class of portable photonic sensor platforms when combined with integrated with quantum cascade laser and detectors.


2021 ◽  
pp. 147592172110339
Author(s):  
Guoqiang Liu ◽  
Binwen Wang ◽  
Li Wang ◽  
Yu Yang ◽  
Xiaguang Wang

Due to no requirement for direct interpretation of the guided wave signal, probability-based diagnostic imaging (PDI) algorithm is especially suitable for damage identification of complex composite structures. However, the weight distribution function of PDI algorithm is relatively inaccurate. It can reduce the damage localization accuracy. In order to improve the damage localization accuracy, an improved PDI algorithm is proposed. In the proposed algorithm, the weight distribution function is corrected by the acquired relative distances from defects to all actuator–sensor pairs and the reduction of the weight distribution areas. The validity of the proposed algorithm is assessed by identifying damages at different locations on a stiffened composite panel. The results show that the proposed algorithm can identify damage of a stiffened composite panel accurately.


Author(s):  
Kuan Ye ◽  
Kai Zhou ◽  
Ren Zhigang ◽  
Ruizhe Zhang ◽  
Chunsheng Li ◽  
...  

The power transmission tower’s ground electrode defect will affect its normal current dispersion function and threaten the power system’s safe and stable operation and even personal safety. Aiming at the problem that the buried grounding grid is difficult to be detected, this paper proposes a method for identifying the ground electrode defects of transmission towers based on single-side multi-point excited ultrasonic guided waves. The geometric model, ultrasonic excitation model, and physical model are established, and the feasibility of ultrasonic guided wave detection is verified through the simulation and experiment. In actual inspection, it is equally important to determine the specific location of the defect. Therefore, a multi-point excitation method is proposed to determine the defect’s actual position by combining the ultrasonic guided wave signals at different excitation positions. Besides, the precise quantification of flat steel grounding electrode defects is achieved through the feature extraction-neural network method. Field test results show that, compared with the commercial double-sided excitation transducer, the single-sided excitation transducer proposed in this paper has a lower defect quantization error in defect quantification. The average quantization error is reduced by approximately 76%.


2013 ◽  
Vol 113 (14) ◽  
pp. 144904 ◽  
Author(s):  
Pasi Karppinen ◽  
Ari Salmi ◽  
Petro Moilanen ◽  
Timo Karppinen ◽  
Zuomin Zhao ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document