How can we protect cancer nurses from exposure to hazardous drugs?

2021 ◽  
Vol 30 (4) ◽  
pp. S16-S20
Author(s):  
Christine Clark

Freelance medical writer Christine Clark ( [email protected] ) reports on an online meeting held in November 2020 on protecting nursing working in oncology from exposure to hazardous drugs

2021 ◽  
Vol 30 (17) ◽  
pp. S4-S8
Author(s):  
Christine Clark

Freelance medical writer Christine Clark ( [email protected] ) reports on an online meeting held in April 2021 on protecting nursing staff working in oncology from exposure to hazardous drugs


2017 ◽  
Vol 49 ◽  
pp. 72-78 ◽  
Author(s):  
Janine Zimmer ◽  
Stefanie Hartl ◽  
Katrin Standfuß ◽  
Till Möhn ◽  
Astrid Bertsche ◽  
...  

2021 ◽  
pp. 107815522110235
Author(s):  
Hao ML ◽  
Wang T ◽  
Zhu JQ ◽  
Song YJ ◽  
Gong TJ ◽  
...  

Objectives The aims of the study were to evaluate the external contamination of hazardous drug vials used in Chinese hospitals and to compare environmental contamination generated by a robotic intelligent dispensing system (WEINAS) and a manual compounding procedure using a biological safety cabinet (BSC). Methods Cyclophosphamide, fluorouracil, and gemcitabine were selected as the representative hazardous drugs to monitor surface contamination of vials. In the comparative analysis of environmental contamination from manual and robotic compounding, wipe samples were taken from infusion bags, gloves, and the different locations of the BSC and the WEINAS robotic system. In this study, high-performance liquid chromatography coupled with double mass spectrometer (HPLC-MS/MS) was employed for sample analysis. Results (1) External contamination was measured on vials of all three hazardous drugs. The contamination detected on fluorouracil vials was the highest with an average amount up to 904.33 ng/vial, followed by cyclophosphamide (43.51 ng/vial), and gemcitabine (unprotected vials of 5.92 ng/vial, protected vials of 0.66 ng/vial); (2) overall, the environmental contamination induced by WEINAS robotic compounding was significantly reduced compared to that by manual compounding inside the BSC. Particularly, compared with manual compounding, the surface contamination on the infusion bags during robotic compounding was nearly nine times lower for cyclophosphamide (10.62 ng/cm2 vs 90.43 ng/cm2), two times lower for fluorouracil (3.47 vs 7.52 ng/cm2), and more than 23 times lower for gemcitabine (2.61 ng/cm2 vs 62.28 ng/cm2). Conclusions The external contamination occurred extensively on some hazardous drug vials that commonly used in Chinese hospitals. Comparison analysis for both compounding procedures revealed that robotic compounding can remarkably reduce environmental contamination.


2020 ◽  
Vol 4 (3-4) ◽  
pp. 119-125
Author(s):  
Marie Palamini ◽  
Geneviève Mercier ◽  
Jean-François Bussières

AbstractBackgroundIn the hospital setting, trace contamination with hazardous medications comes primarily from the manipulation of containers used in preparing and administering drugs. However, some traces of medications also come from the excreta of patients.MethodsThis descriptive exploratory study involved direct observation and discussion. The aim was to map potential contamination associated with handling babies’ excreta through diaper management. The study was conducted at CHU Sainte Justine (Montréal, Québec, Canada), a 500-bed mother and child facility with 38 beds for hematology-oncology and bone marrow transplant. A list of key steps related to the management of diapers by a parent or caregiver on a pediatric unit was established by the investigators. A data collection grid was then developed and reviewed by a member of the research team.ResultsA total of six diaper changes, by six distinct individuals, were observed in August and September 2019. Transport of a soiled diaper for weighing outside the baby’s room by an additional caregiver was also observed and recorded. In total, 25 individual steps in diaper management and 28 potential failure modes were identified through mapping.ConclusionsChanging a baby’s diaper involves many individual steps, which are subject to numerous failure modes that can contribute to contamination with traces of hazardous drugs. A good understanding of these process steps and failure modes is desirable to better train caregivers and parents to reduce trace contamination with hazardous drugs.


Sign in / Sign up

Export Citation Format

Share Document