Clinical Evaluation of the Implants which were installed in Esthetic Area: Retrospective Clinical Study Clinical Evaluation of the Implants which were installed in Esthetic Area: Retrospective Clinical Study

2017 ◽  
Vol 21 (4) ◽  
pp. 210-216
Author(s):  
Sang-Yun Kim ◽  
Young-Kyun Kim
2021 ◽  
Author(s):  
Yan Dai ◽  
Jin Xu ◽  
Xiao-Hui Han ◽  
Fu-Zhai Cui ◽  
Dong-Sheng Zhang ◽  
...  

Abstract Background: The purpose of this retrospective clinical study was to evaluate the clinical efficacy of mineralized collagen (MC) versus Bio-Oss for immediate implant implantation in esthetic area. Methods: Medical records of Department of Oral and Maxillofacial Surgery of Shandong Provincial Hospital were screened for patients who had been treated with immediate implant implantation in the esthetic area using either MC( Allgens®) or Bio-Oss®, between January 2018 and December 2019. All patients fulfilling the in-/exclusion criteria and following for a minimum period of 1 year after surgery were enrolled into the presented study. Implant survival rate, radiographic, esthetic and patient satisfactory evaluations were performed.Results: Altogether, 70 patients were included in the study; a total of 80 implants were inserted. All implants had good initial stability after implantation. The survival rate of implants was 100% at 1-year follow-up. The differences in horizontal and vertical bone loss between the Trail group (0.72±0.26mm, 1.62±0.84mm) and the Control group (0.70±0.52 mm, 1.57±0.88mm) were statistically no significant at 6 months after permanent restoration. Similar results occurred at 12 months after permanent restoration. Clinical acceptability defined by PES ≥ 6 (6.07±1.62 vs. 6.13±1.41) was not significantly different between groups. Patient satisfaction estimated by VAS was similar (8.56±1.12 vs. 8.27±1.44), and the difference was not statistically significant between the two groups.Conclusions: The biomimetic MC seems to be a suitable and feasible option for bone graft material in immediate implant implantation.


2021 ◽  
pp. 112972982110025
Author(s):  
Yu-Xia Yin ◽  
Wei Gao ◽  
Sheng-Yu Feng ◽  
Deng-Xu Wang ◽  
Min Wan ◽  
...  

Objective: Safety and efficacy of ECG-guided PICC insertion using a new silicon catheter with a conductive tip was evaluated in daily practice. Methods: A retrospective study was conducted on 1659 patients who accepted successful tip-conductive PICC placement and clinically followed-up until the catheter removal between January 2018 and April 2019. Baseline of patient characteristics, catheter placement characteristics, date of dressing changes as well as records of catheter-related complications were extracted from a special designed mobile APP. Results: The first-attempt success (success of placing catheter tip to the ideal position by primary indwelling operation) rate of PICC placement was 99.3%. The average duration of PICC placement was 128.7 ± 39.5 days and 1535 patients (92.5%) reached the therapy end-point without any complications and removed the catheter normally. The cumulative rates of total complications were 7.5%, including exit site infection (2.5%), phlebitis (0.9%), DVT (1.0%), catheter malposition (1.1%), catheter breakage (0.1%), and liquid extravasation (1.8%). In multivariable logistic regression analyses, hyperlipidemia, diabetes mellitus, lung cancer, stomach cancer, and lymphoma were significantly associated with increased risk of complications, as the independent risk factors. Conclusions: This retrospective clinical study demonstrates that ECG-guided insertion of a new tip-conductive PICC is associated with a high rate of first-attempt success and low rate of catheter related complications.


2021 ◽  
Vol 106 ◽  
pp. 103586
Author(s):  
Constance Wong ◽  
Igor R. Blum ◽  
Chris Louca ◽  
Martin Sparrius ◽  
Kristina Wanyonyi

Sign in / Sign up

Export Citation Format

Share Document