scholarly journals Flow Pattern and Frictional Losses in Pulsating Pipe Flow : Part 5, Wall Shear Stress and Flow Pattern in a Laminar Flow

1981 ◽  
Vol 24 (187) ◽  
pp. 75-81 ◽  
Author(s):  
Munekazu OHMI ◽  
Manabu IGUCHI ◽  
Tateo USUI
1994 ◽  
Vol 116 (3) ◽  
pp. 645-649 ◽  
Author(s):  
Josef Daniel Ackerman ◽  
Louis Wong ◽  
C. Ross Ethier ◽  
D. Grant Allen ◽  
Jan K. Spelt

We present a Preston tube device that combines both total and static pressure readings for the measurement of wall shear stress. As such, the device facilitates the measurement of wall shear stress under conditions where there is streamline curvature and/or over surfaces on which it is difficult to either manufacture an array of static-pressure taps or to position a single tap. Our “Preston-static” device is easily and conveniently constructed from commercially available regular and side-bored syringe needles. The pressure difference between the total pressure measured in the regular syringe needle and the static pressure measured in the side-bored one is used to determine the wall shear stress. Wall shear stresses measured in pipe flow were consistent with independently determined values and values obtained using a conventional Preston tube. These results indicate that Preston-static tubes provide a reliable and convenient method of measuring wall shear stress.


AIChE Journal ◽  
1996 ◽  
Vol 42 (8) ◽  
pp. 2369-2373 ◽  
Author(s):  
Charles H. Newton ◽  
Masud Behnia

2005 ◽  
Vol 48 (4) ◽  
pp. 468-476
Author(s):  
Hisashi FUJII ◽  
Ryuhei YAMAGUCHI ◽  
Kazuo TANISHITA

2008 ◽  
Vol 130 (6) ◽  
Author(s):  
F. P. P. Tan ◽  
G. Soloperto ◽  
S. Bashford ◽  
N. B. Wood ◽  
S. Thom ◽  
...  

In this study, newly developed two-equation turbulence models and transitional variants are employed for the prediction of blood flow patterns in a diseased carotid artery where the growth, progression, and structure of the plaque at rupture are closely linked to low and oscillating wall shear stresses. Moreover, the laminar-turbulent transition in the poststenotic zone can alter the separation zone length, wall shear stress, and pressure distribution over the plaque, with potential implications for stresses within the plaque. Following the validation with well established experimental measurements and numerical studies, a magnetic-resonance (MR) image-based model of the carotid bifurcation with 70% stenosis was reconstructed and simulated using realistic patient-specific conditions. Laminar flow, a correlation-based transitional version of Menter’s hybrid k‐ϵ∕k‐ω shear stress transport (SST) model and its “scale adaptive simulation” (SAS) variant were implemented in pulsatile simulations from which analyses of velocity profiles, wall shear stress, and turbulence intensity were conducted. In general, the transitional version of SST and its SAS variant are shown to give a better overall agreement than their standard counterparts with experimental data for pulsatile flow in an axisymmetric stenosed tube. For the patient-specific case reported, the wall shear stress analysis showed discernable differences between the laminar flow and SST transitional models but virtually no difference between the SST transitional model and its SAS variant.


Sign in / Sign up

Export Citation Format

Share Document