606 Measurement of Bubbles and Droplets Dynamics in Multi-Phase Flow by Four-Tip Optical Fiber Probe

2005 ◽  
Vol 2005 (0) ◽  
pp. 80
Author(s):  
Akihiro SAKAMOTO ◽  
Yoshiaki TAKEISHI ◽  
Takayuki SAITO
2011 ◽  
Vol 361-363 ◽  
pp. 671-675 ◽  
Author(s):  
Feng Yun Chen ◽  
Wei Min Liu

A way of measuring the average cross-sectional void fraction for vertically rising oil pipes by using closing valves quickly and optical fiber probe has been researched. Experiments were performed in oil-gas two-phase flow and the range of the average void fraction is 0.1~0.5. The relationship between average cross-sectional void fraction of a oil-gas two-phase flow and pipe’s center void fraction in vertically rising oil pipes, for different pipe diameters and varying oil flow, is obtained. An exponential model of average void fraction is also obtained with reference to Bankoff’s[1] variable density model. It is found that local void fraction reduces from center in radial direction and the local void fraction maximum value appears in the pipe’s center.


Coatings ◽  
2021 ◽  
Vol 11 (11) ◽  
pp. 1420
Author(s):  
Shuaifei Cui ◽  
Junfeng Liu ◽  
Kui Li ◽  
Qinze Li

To solve the problem that traditional single-probe instruments cannot accurately measure the gas and water holdup, the domestic design of the array holdup measuring instrument Array of Optical and Resistance Tool (AORT), composed of five sets of optical fiber probes and five sets of resistance probes, is carried out in both gas–water and oil–water. Simulated measurement experiments were conducted under different water cut in phase flow. Through the analysis of the experimental data, the response relationship between the optical fiber probe and the resistance probe of the AORT instrument in different fluids was obtained. Then, the data under different conditions of fluid, flowrate and water cut in the experiment were compared by drawing. Interpolation algorithm was used to perform two-maintenance holdup imaging, and finally the holdup image was compared with the pictures of the flow in the pipe recorded during the experiment. The results show that the resistance probe has a better response under low water cut conditions, and the optical fiber probe has a better response under high gas cut conditions, which is consistent with the theoretical analysis. The imaging diagram and the flow pattern in the pipe during the experiment are in good agreement. It can be seen that the accuracy of the holdup measured by the AORT instrument under the test conditions is verified, and can provide technical support for further carrying out the measurement and interpretation of the holdup in future, as well as the improvement of the instrument and on-site testing.


2020 ◽  
pp. 1-1
Author(s):  
Wen Zhang ◽  
Haoye Li ◽  
Lianqing Zhu ◽  
Mingli Dong ◽  
Fanyong Meng

2020 ◽  
Vol 76 ◽  
pp. 103187
Author(s):  
C.R. Clarkson ◽  
B. Yuan ◽  
Z. Zhang ◽  
F. Tabasinejad ◽  
H. Behmanesh ◽  
...  

2016 ◽  
Vol 13 (02) ◽  
pp. 381-415
Author(s):  
Debora Amadori ◽  
Paolo Baiti ◽  
Andrea Corli ◽  
Edda Dal Santo

In this paper we study the flow of an inviscid fluid composed by three different phases. The model is a simple hyperbolic system of three conservation laws, in Lagrangian coordinates, where the phase interfaces are stationary. Our main result concerns the global existence of weak entropic solutions to the initial-value problem for large initial data.


Sensors ◽  
2018 ◽  
Vol 18 (4) ◽  
pp. 995 ◽  
Author(s):  
Takashi Katagiri ◽  
Kyosuke Shibayama ◽  
Takeru Iida ◽  
Yuji Matsuura

Sign in / Sign up

Export Citation Format

Share Document