615 Natural Refrigerant for Vapor Compression Heat Pumps

2001 ◽  
Vol 2001.7 (0) ◽  
pp. 203-204
Author(s):  
Eiji HIHARA
2001 ◽  
Author(s):  
Srinivas Garimella

Abstract This paper discusses several different approaches to increase the energy efficiency and decrease the environmental impact of space-conditioning systems. The use of microchannel components and hydronic coupling is presented as a method to drastically reduce the size and refrigerant inventories of the refrigerant-carrying components of vapor-compression heat pumps. Design aspects of heat pumps using carbon dioxide, a natural refrigerant with minimal environmental impact, are discussed, and novel component geometries that offer compactness are presented. The advantages of absorption heat pumps using waste heat and natural gas are discussed, and innovative component designs are presented. It is believed that these innovations will hasten the commercialization of these environmentally benign alternatives to CFC- and HCFC-based vapor-compression systems. The environmental benefits of waste heat-driven absorption chillers are quantified in terms of the energy savings, greenhouse gas emission reductions, and installed electric power reductions. Ground coupling of these heat pumps is also discussed, with specific examples of the performance improvement over similar air-coupled heat pumps.


1997 ◽  
Vol 119 (2) ◽  
pp. 183-191 ◽  
Author(s):  
Xiang-Dong He ◽  
Sheng Liu ◽  
Haruhiko H. Asada

This paper presents a new lumped-parameter model for describing the dynamics of vapor compression cycles. In particular, the dynamics associated with the two heat exchangers, i.e., the evaporator and the condenser, are modeled based on a moving-interface approach by which the position of the two-phase/single-phase interface inside the one-dimensional heat exchanger can be properly predicted. This interface information has never been included in previous lumped-parameter models developed for control design purpose, although it is essential in predicting the refrigerant superheat or subcool value. This model relates critical performance outputs, such as evaporating pressure, condensing pressure, and the refrigerant superheat, to actuating inputs including compressor speed, fan speed, and expansion valve opening. The dominating dynamic characteristics of the cycle around an operating point is studied based on the linearized model. From the resultant transfer function matrix, an interaction measure based on the Relative Gain Array reveals strong cross-couplings between various input-output pairs, and therefore indicates the inadequacy of independent SISO control techniques. In view of regulating multiple performance outputs in modern heat pumps and air-conditioning systems, this model is highly useful for design of multivariable feedback control.


MRS Bulletin ◽  
2022 ◽  
Author(s):  
Shuang Cui ◽  
Adewale Odukomaiya ◽  
Judith Vidal

Abstract Because of the complexity of modern buildings—with many interconnected materials, components, and systems—fully electrifying buildings will require targeted R&D and efficient coordination across those material, component, and system levels. Because buildings that consume the smallest amount of energy are easier to electrify, energy efficiency is a crucial step toward fully electrified buildings. Materials advances will play an important role in both reducing the energy intensity of buildings and electrifying their remaining energy use. Materials are currently being explored, discovered, synthesized, evaluated, optimized, and implemented across many building components, including solid-state lighting; dynamic windows and opaque envelopes; cold climate heat pumps; thermal energy storage; heating, ventilating, and air conditioning (HVAC); refrigeration; non-vapor compression HVAC; and more. In this article, we review the current state-of-the-art of materials for various buildings end uses and discuss R&D challenges and opportunities for both efficiency and electrification. Graphical abstract


Energy ◽  
2019 ◽  
Vol 182 ◽  
pp. 110-121 ◽  
Author(s):  
Riccardo Bergamini ◽  
Jonas Kjær Jensen ◽  
Brian Elmegaard

2020 ◽  
Vol 324 ◽  
pp. 02007
Author(s):  
Gennady A. Ilyn ◽  
Ilya I. Malafeev ◽  
Vladimir B. Sapojnikov

One of the most common and reliable methods of water treatment is the method of thermal distillation. Despite the reliability of the method, its application is constrained by high energy intensity. The most effective way to reduce the cost of production of distillate is the use of thermal transformers, providing regenerate and heat recovery phase transformations of the distillate. The use of working fluid with the most favorable thermodynamic properties is of paramount importance for the creation of high efficiency thermotransformers. The work is considered working fluid for high-temperature heat pumps and the results of the calculation-experimental study of high-temperature vapor compression heat-pumping distiller on natural working substance n-pentan.


Desalination ◽  
1997 ◽  
Vol 114 (3) ◽  
pp. 253-275 ◽  
Author(s):  
Faisal Al-Juwayhel ◽  
Hisham El-Dessouky ◽  
Hisham Ettouney

1980 ◽  
Vol 102 (3) ◽  
pp. 203-210 ◽  
Author(s):  
E. A. Kush

As part of the study of Solar Assisted Heat Pump (SAHP) systems, the performance of the heat pump component itself under conditions attendant to series solar input is being investigated. Notably the effect of high source temperatures, for which current heat pumps are not designed, and the associated thermodynamic potential to raise performance are of interest. This paper presents theoretical predictions, results of systematic experiments run on a special heat pump simulator, and interpretation/analysis of how high Coefficients of Performance (COP) heat pumps can be used in installed SAHP systems. The latter aspect is vital for—although results have shown that substantial increase in COP can be achieved even using off-the-shelf heat pump components—the more difficult problem is supplying sufficient solar energy to the heat pump with a practical, cost-competitive system. The approach taken to the high temperature heat pump study makes the results generally applicable to any vapor compression heat pump with related evaporating temperatures.


Sign in / Sign up

Export Citation Format

Share Document