2A2-J10 Development of Portable Energy-Saving Type Air Supply System using Variable Volume Tank(Mechanism and Control for Actuator)

2011 ◽  
Vol 2011 (0) ◽  
pp. _2A2-J10_1-_2A2-J10_4
Author(s):  
Tatsuyuki Iwawaki ◽  
Daisuke Sasaki ◽  
Toshiro Noritsugu ◽  
Masahiro Takaiwa
2012 ◽  
Vol 24 (3) ◽  
pp. 464-471 ◽  
Author(s):  
Tatsuyuki Iwawaki ◽  
◽  
Daisuke Sasaki ◽  
Toshiro Noritsugu ◽  
Masahiro Takaiwa

The purpose of this study is to develop a portable energy-saving type air supply system. A variable volume tank is developed in order to drive a pneumatic actuator with a low discharge pressure in a tank. The developed tank composed of flexible materials can store pneumatic energy by converting it to elastic energy. In this paper, the composition of the system, the structure and characteristic of a variable volume tank and experiment of driving actuator with constant and variable volume tanks are discussed. As a result, the variable volume tank can drive the actuator at a lower supply pressure than with the constant volume tank.


2014 ◽  
Vol 960-961 ◽  
pp. 635-638
Author(s):  
Li Bai ◽  
Xue Zhi Zhou ◽  
Yan Wang ◽  
Ya Wei Hua

More and more attentions have been paid on ice-storage low temperature air supply system because of its notable energy saving effects and comfort. The paper expatiate on that ice-storage low temperature air supply system brings a series of especial superiority to modern air-condition cause. The results show that low temperature air supply system can exert the potential advantage of ice-storage further. The combination of ice-storage and low temperature air supply system can obtain an “integrated approach”, which can save energy resources and improve human body comfort and indoor air quality.


2022 ◽  
Vol 253 ◽  
pp. 115159
Author(s):  
Dongdong Zhao ◽  
Lei Xia ◽  
Hanbin Dang ◽  
Zezhong Wu ◽  
Haiyan Li

Energy ◽  
2019 ◽  
Vol 188 ◽  
pp. 116078 ◽  
Author(s):  
Duo Yang ◽  
Rui Pan ◽  
Yujie Wang ◽  
Zonghai Chen

2016 ◽  
Vol 41 (36) ◽  
pp. 16230-16239 ◽  
Author(s):  
Zhixiang Liu ◽  
Lun Li ◽  
Yi Ding ◽  
Huiwen Deng ◽  
Weirong Chen

2010 ◽  
Vol 34-35 ◽  
pp. 836-840
Author(s):  
De Wen Kong ◽  
Mao Lin Cai ◽  
Tie Yuan Sun

In this paper, based on the new concept air power of pneumatic system’s energy consumption, we proposed series of practical program to optimize the air supply system. This program discussed a method of how to keep air pressure stable and how to make the amount of air compressors to match the real-time air consumption after using different air pressure for different devices, thus reducing energy loss of air supply system and energy consumption of air compressor group. The result of present work implied that this program achieved the desired effect of energy saving and provided a reference for energy-saving pneumatic system’s design.


Sign in / Sign up

Export Citation Format

Share Document