Acoustically Forced Vibration of Greenhouse Tomato Blossoms to Induce Pollination

1968 ◽  
Vol 11 (5) ◽  
pp. 0731-0735 ◽  
Author(s):  
W. R. DeTar ◽  
C. G. Haugh and J. F. Hamilton
2013 ◽  
Vol 21 (6) ◽  
pp. 681-688
Author(s):  
Yan-Xia MA ◽  
Jing REN ◽  
Gang CAO ◽  
Wen-Lin LI ◽  
Guo-Bin ZHANG ◽  
...  

2020 ◽  
Vol 2020 ◽  
pp. 1-17 ◽  
Author(s):  
Trung Thanh Tran ◽  
Van Ke Tran ◽  
Pham Binh Le ◽  
Van Minh Phung ◽  
Van Thom Do ◽  
...  

This paper carries out forced vibration analysis of graphene nanoplatelet-reinforced composite laminated shells in thermal environments by employing the finite element method (FEM). Material properties including elastic modulus, specific gravity, and Poisson’s ratio are determined according to the Halpin–Tsai model. The first-order shear deformation theory (FSDT), which is based on the 8-node isoparametric element to establish the oscillation equation of shell structure, is employed in this work. We then code the computing program in the MATLAB application and examine the verification of convergence rate and reliability of the program by comparing the data of present work with those of other exact solutions. The effects of both geometric parameters and mechanical properties of materials on the forced vibration of the structure are investigated.


Author(s):  
Dalong Tian ◽  
Jianguo Guo

This study aims to develop an advanced integral terminal sliding-mode robust control method using a disturbance observer (DO) to suppress the forced vibration of a large space intelligent truss structure (LSITS). First, the dynamics of the electromechanical coupling of the piezoelectric stack actuator and the LSITS, based on finite element and Lagrangian methods, are established. Subsequently, to constrict the vibration of the structure, a novel integral terminal sliding-mode control (ITSMC) law for the DO is used to estimate the parameter perturbation of the LSITS based on a continuous external disturbance. Simulation results show that, under a forced vibration and compared with the ITSMC system without a DO, the displacement amplitude of the ITSMC system with the DO is effectively reduced. In the case where the model parameters of the LSITS deviate by ±50%, and an unknown continuous external disturbance exists, the control system with the DO can adequately attenuate the structural vibration and realize robust control. Concurrently, the voltage of the employed piezoelectric stack actuator is reduced, and voltage jitter is alleviated.


2020 ◽  
Vol 243 ◽  
pp. 112249 ◽  
Author(s):  
Peilin Fu ◽  
Jianghong Yuan ◽  
Xu Zhang ◽  
Guozheng Kang ◽  
Ping Wang ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document