Neutron and Gamma-Ray Effects on Self-Powered In-Core Radiation Detectors

1974 ◽  
Vol 54 (4) ◽  
pp. 395-415 ◽  
Author(s):  
H. D. Warren ◽  
N. H. Shah
2005 ◽  
Author(s):  
A. M. Swidan ◽  
S. M. El‐Ghanam ◽  
H. A. Ashry ◽  
F. A. S. Soliman

2009 ◽  
Vol 24 (1) ◽  
pp. 61-67 ◽  
Author(s):  
Milos Vujisic ◽  
Koviljka Stankovic ◽  
Aleksandra Vasic

This paper compares the reliability of standard commercial Erasable Programmable Read Only Memory (EPROM) and Electrically Erasable Programmable Read Only Memory (E2PROM) components exposed to gamma rays. The results obtained for CMOS-based EPROM (NM27C010) and E2PROM (NM93CS46) components provide the evidence that EPROMs have greater radiation hardness than E2PROMs. Moreover, the changes in EPROMs are reversible, and after erasure and reprogramming all EPROM components restore their functionality. On the other hand, changes in E2PROMs are irreversible. The obtained results are analyzed and interpreted on the basis of gamma ray interaction with the CMOS structure.


1982 ◽  
Vol 16 ◽  
Author(s):  
John H. Howes ◽  
John Watling

ABSTRACTThis paper describes the fabrication of mercuric iodide nuclear radiation detectors suitable for X and gamma ray spectrometry at room temperature. The active area of the detectors studied are between 0.2 and 1.5cm sq and they are up to 0.5mm thick. The method of producing a stable electrical contact to the crystal using sputtered germanium has been studied. The X-ray resolution of a 1.5cm sq. area detector at 32 keV is 2.3 keV FWHM when operated at room temperature in conjunction with a time variant filter amplifier. A factor which is important in the fabrication of the detector is the surface passivation necessary to achieve a useful detector life.This type of detector has been used on a wavelength dispersive X-ray spectrometer for energy measurements between 10 and 100 keV. The advantages over the scintillation counter, more commonly used, is the improved resolution of the HgI2 detector and its smaller size. The analyser is primarily used for the detection of low levels of heavy metals on particulate filters. The detectors have also been used on an experimental basis for gamma ray backscatter measurements in the medical field.


2020 ◽  
Vol 176 ◽  
pp. 109027
Author(s):  
Qiang Xu ◽  
Yong Guo ◽  
Chen Li ◽  
Bohao Zhang ◽  
Xiang Wang ◽  
...  

2006 ◽  
Author(s):  
Douglas McGregor ◽  
Alireza Kargar ◽  
Mark Harrison ◽  
Adam Brooks ◽  
Walter McNei ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document