High dose gamma-ray effects of solution-growth vertical ZnO nanowires

2020 ◽  
Vol 176 ◽  
pp. 109027
Author(s):  
Qiang Xu ◽  
Yong Guo ◽  
Chen Li ◽  
Bohao Zhang ◽  
Xiang Wang ◽  
...  
2019 ◽  
Vol 9 (02) ◽  
Author(s):  
Amal Kamil Abdul Sada ◽  
Amany Mohamed Al-Kaysi

This is an experimental trial to prepare a vaccine from gamma-irradiated Giardia lamblia which is evaluated in experimental animals. The study was conducted from December 2015 to April 2016. The field survey of the parasite was conducted from those patients attending the laboratories of the Alawi Children's Hospital in Rusafa and the Al-Yarmouk Teaching Hospital in Karkh, through which 1250 stool samples of different age groups were examined. Five groups of mice were used in the study; the first was injected with normal saline and considered as a negative control group, the second was injected with cystic form of non-irradiated Giardia lamblia and considered as a positive control group, whereas the other three groups were injected with gamma irradiated Giardia lamblia at three different doses 10, 15 and 25 rad respectively. Giardia lamblia was primarily cultivated in liver infusion agar for ten days to obtain the active phase. On the sixth day, the cystic phase was purified and standardized to be used in the infection of mice with or without the exposure of gamma rays. Mice showed high sensitivity to parasitic infestation, in the gamma non-irradiated and the irradiated with gamma 10 rad, and 15 rad irradiated groups which was 100%. The results expressed an excystation process of the depleted phases and the release of the feeder phases. The results of the three irradiated groups consisted of histopathological changes of the small, and the rectum by dissection after two weeks of infection, with intestine amputation lesions, as well as ulceration and inflammation of the inflammatory cells represented in small numbers of neutrophil, lymphocytes, and eosinophils. The presence of ulceration and fall of epithelial cells in the intestinal cavity has been shown, and different forms of the parasite have been observed. Mice which was injected with irradiated G lamblia at high dose (25 rad), not show and sensitivity to the challenge infection and no excystation of thy parasite had been done. After 2 wreaks, a comparison was achieved between all study groups in which no histopathological changes were noticed in the mice irradiated with dose of25 rad. After another two weeks, a challenge dose was given (un-attenuated G lamblia) and mice were dissected after another two weeks, no changes on the level of histopathology of intestinal tissue were noticed the results suggested that mice acquire an immunity against the parasite infection.


2005 ◽  
Author(s):  
A. M. Swidan ◽  
S. M. El‐Ghanam ◽  
H. A. Ashry ◽  
F. A. S. Soliman

2021 ◽  
Vol 16 (12) ◽  
pp. T12005
Author(s):  
J. Nagata ◽  
S. Yamamoto ◽  
Y. Noguchi ◽  
T. Nakaya ◽  
K. Okudaira ◽  
...  

Abstract In high-dose-rate (HDR) brachytherapy, verification of the Ir-192 source's position during treatment is needed because such a source is extremely radioactive. One of the methods used to measure the source position is based on imaging the gamma rays from the source, but the absolute position in a patient cannot be confirmed. To confirm the absolute position, it is necessary to acquire an optical image in addition to the gamma ray image at the same time as well as the same position. To simultaneously image the gamma ray and optical images, we developed an imaging system composed of a low-sensitivity, high-resolution gamma camera integrated with a CMOS camera. The gamma camera has a 1-mm-thick cerium-doped yttrium aluminum perovskite (YAIO3: YAP(Ce)) scintillator plate optically coupled to a position-sensitive photomultiplier (PSPMT), and a 0.1-mm-diameter pinhole collimator was mounted in front of the camera to improve spatial resolution and reduce sensitivity. We employed the concept of a periscope by placing two mirrors tilted at 45 degrees facing each other in front of the gamma camera to image the same field of view (FOV) for the gamma camera and the CMOS camera. The spatial resolution of the imaging system without the mirrors at 100 mm from the Ir-192 source was 3.2 mm FWHM, and the sensitivity was 0.283 cps/MBq. There was almost no performance degradation observed when the mirrors were positioned in front of the gamma camera. The developed system could measure the Ir-192 source positions in optical and gamma ray images. We conclude that the developed imaging system has the potential to measure the absolute position of an Ir-192 source in real-time clinical measurements.


2009 ◽  
Vol 24 (1) ◽  
pp. 61-67 ◽  
Author(s):  
Milos Vujisic ◽  
Koviljka Stankovic ◽  
Aleksandra Vasic

This paper compares the reliability of standard commercial Erasable Programmable Read Only Memory (EPROM) and Electrically Erasable Programmable Read Only Memory (E2PROM) components exposed to gamma rays. The results obtained for CMOS-based EPROM (NM27C010) and E2PROM (NM93CS46) components provide the evidence that EPROMs have greater radiation hardness than E2PROMs. Moreover, the changes in EPROMs are reversible, and after erasure and reprogramming all EPROM components restore their functionality. On the other hand, changes in E2PROMs are irreversible. The obtained results are analyzed and interpreted on the basis of gamma ray interaction with the CMOS structure.


Author(s):  
Huifen Wei ◽  
Wenping Geng ◽  
Kaixi Bi ◽  
Tao Li ◽  
Xiangmeng Li ◽  
...  

Abstract LiNbO3 (LN)-based micro-electro-mechanical systems (MEMS) vibration sensors exhibit giant prospection in extreme environments, where exist a great amount of irradiation. However, to the best of our knowledge, it is still unknown whether the irradiation affects the performance of LN-based piezoelectric MEMS sensors. Based on this consideration, it is necessary to model the irradiation environment to investigate the effect of high dosage irradiation on LN-based vibration sensors. Firstly, the theoretical work is done to study the Compton Effect on the Gamma-ray irradiation with Co-60 source. After irradiation, X-ray diffraction (XRD) characterization was performed to verify the effect of irradiation on the crystalline of LN thin film. Meanwhile, the performances of output voltages on the five MEMS devices under various dosage of irradiation are compared. As a result, a neglected shift of 0.02 degrees was observed from the XRD image only under maximum irradiation dosage of 100 Mrad(Si). Moreover, the output voltages of cantilever-beam vibration sensors decrease by 3.1%. Therefore, it is verified that the γ-ray irradiation has very little influence on the LN-based MEMS vibration sensors, which have great attraction on the materials and sensors under high-dose irradiation.


2020 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Awad AL Zahrany ◽  
Khalid Rabaeh ◽  
Molham Eyadeh ◽  
Ahmed Basfar

Purpose The purpose of this paper is to present a radiochromic film dosimeter containing polyvinyl alcohol (PVA) matrix and various concentrations of methyl red (MR) dye for high dose measurements. Design/methodology/approach The MR-PVA films were exposed to irradiation up to 60 kGy using 60Co source of gamma ray. The ultraviolet and visible regions (UV/VIS) spectrophotometry were used to examine the optical density of pre-and post-irradiated dosimeters at 424 nm. Findings The dose sensitivity of MR-PVA films increases significantly with increasing MR dye concentrations in the dose range of 5 to 60 kGy. The impact of relative humidity, irradiation temperature, dose rate and the stability of the films has been analyzed. The overall uncertainty of the MR-PVA film dosimeter is 6.12% (Double Standard-deviation, 95% confidence level). Practical implications It was found that the MR-PVA films may be used as high dose dosimeter with an acceptable overall uncertainty in routine industrial radiation processing. Originality/value The color bleaching of irradiated MR-PVA films in terms of specific absorbance curves increases significantly with increasing absorbed dose up to 60 kGy.


2011 ◽  
Vol 311-313 ◽  
pp. 419-431
Author(s):  
Kwo Ping Chang ◽  
Zhi Yuan Lin ◽  
Mao Chin Hung ◽  
Bor Tsung Hsieh

The optimal parameters of the chitosan-coated ferrofluid under two patterns of irradiation were investigated in this study. The quality characteristics were set both to the SAR (specific absorption rate, W/g) and the particle size (nm). The control factors were chosen as the gamma irradiation dose (Gy), the quantities of chitosan (g), and the molar ratio of Fe3+to Fe2+. It shows that SAR is a better choice for determining the quality characteristic. The quantities of chitosan have a less significant impact on SAR. The optimal condition for the Fe3+/Fe2+ratio was found to be between 2.0 to 2.5 when synthesizing the magnetite Fe3O4cores. High dose (100 k Gy in this study) of gamma ray irradiation given only to the solid chitosan will have a significantly positive effect on SAR of the chitosan-coated ferrofluid for hyperthermia. However, high dose irradiation of the chitosan-coated ferrofluid tends to destroy the chitosan-magnetite cores bonds.


Sign in / Sign up

Export Citation Format

Share Document