Simulation analysis and preparation of a high optical density laser protection filter

2020 ◽  
Vol 59 (11) ◽  
pp. 3315
Author(s):  
Liangyi Hang ◽  
Weiguo Liu ◽  
Shigeng Song ◽  
Des Gibson ◽  
Shun Zhou ◽  
...  
Author(s):  
James R. Kremer ◽  
Paul S. Furcinitti ◽  
Eileen O’Toole ◽  
J. Richard McIntosh

Characteristics of electron microscope film emulsions, such as the speed, the modulation transfer function, and the exposure dependence of the noise power spectrum, have been studied for electron energies (80-100keV) used in conventional transmission microscopy. However, limited information is available for electron energies in the intermediate to high voltage range, 300-1000keV. Furthermore, emulsion characteristics, such as optical density versus exposure, for new or improved emulsions are usually only quoted by film manufacturers for 80keV electrons. The need for further film emulsion studies at higher voltages becomes apparent when searching for a film to record low dose images of radiation sensitive biological specimens in the frozen hydrated state. Here, we report the optical density, speed and relative resolution of a few of the more popular electron microscope films after exposure to 1MeV electrons.Three electron microscope films, Kodak S0-163, Kodak 4489, and Agfa Scientia 23D56 were tested with a JEOLJEM-1000 electron microscope operating at an accelerating voltage of 1000keV.


2020 ◽  
Vol 90 (3) ◽  
pp. 30502
Author(s):  
Alessandro Fantoni ◽  
João Costa ◽  
Paulo Lourenço ◽  
Manuela Vieira

Amorphous silicon PECVD photonic integrated devices are promising candidates for low cost sensing applications. This manuscript reports a simulation analysis about the impact on the overall efficiency caused by the lithography imperfections in the deposition process. The tolerance to the fabrication defects of a photonic sensor based on surface plasmonic resonance is analysed. The simulations are performed with FDTD and BPM algorithms. The device is a plasmonic interferometer composed by an a-Si:H waveguide covered by a thin gold layer. The sensing analysis is performed by equally splitting the input light into two arms, allowing the sensor to be calibrated by its reference arm. Two different 1 × 2 power splitter configurations are presented: a directional coupler and a multimode interference splitter. The waveguide sidewall roughness is considered as the major negative effect caused by deposition imperfections. The simulation results show that plasmonic effects can be excited in the interferometric waveguide structure, allowing a sensing device with enough sensitivity to support the functioning of a bio sensor for high throughput screening. In addition, the good tolerance to the waveguide wall roughness, points out the PECVD deposition technique as reliable method for the overall sensor system to be produced in a low-cost system. The large area deposition of photonics structures, allowed by the PECVD method, can be explored to design a multiplexed system for analysis of multiple biomarkers to further increase the tolerance to fabrication defects.


1973 ◽  
Vol 29 (03) ◽  
pp. 536-546 ◽  
Author(s):  
M Lacombe ◽  
J Soria ◽  
C Soria ◽  
G d’Angelo ◽  
R Lavallee ◽  
...  

SummaryA new case of congenital dysfibrinogenemia characterized by a prolonged thrombin clotting time and a low optical density of the polymerization curve has been discovered in Montreal. The functional defect is due to an abnormal aggregation of fibrin monomers.The characteristics of this abnormal fibrinogen are serum gélification (Paracoagulation) at 37°, 22° and 4° C, a normal immuno-electrophoretic and electrofocusing pattern, a slight increase in the mobility in the α (A) chain by electrophoresis of the dissociated chains in polyacrylamide gel. However, no abnormality was found in the α (A) chain of the disulphide knot.


1978 ◽  
Vol 39 (02) ◽  
pp. 455-465 ◽  
Author(s):  
Yvonne Stirling ◽  
D J Howarth ◽  
Marguerite Vickers ◽  
W R S North ◽  
T W Meade

SummaryTwo automated methods for two-stage factor VIII assays have been compared with one another, and evaluated in practice. The Depex method records the clotting time when an electric circuit is completed by the formation of a fibrin thread across a hook-type electrode; the Electra method is based on an optical density technique of clot detection. The two methods gave comparable results for measured levels of factor VIII when haemophilic or “normal” plasmas were assayed. Results from the two methods in practice also suggest that both are valid at low and “normal” factor VIII levels. The Electra method is also probably suitable for assays of concentrates; however, the Depex method appears to give falsely high values in these circumstances, and experimental findings suggest that the reason may be that increased viscosity due to the high fibrinogen levels in factor VIII concentrates causes premature closure of the circuit between the two ends of the Depex electrode. The main advantage of the Depex method is that, provided 3 or 4 machines are available, a given number of assays can be completed more quickly than on Electra. The main advantages of Electra are that it is probably subject to less laboratory error than Depex, and that it is suitable for assaying concentrates as well as haemophilic and “normal” plasmas.


1977 ◽  
Vol 37 (02) ◽  
pp. 329-338 ◽  
Author(s):  
Tadahiro Sano ◽  
Takeshi Motomiya ◽  
Hiroh Yamazaki ◽  
Takio Shimamoto

SummaryA new method for assessment of platelet sensitivity to ADP-aggregation was devised. Its reproducibility and the correlations between the values obtained by this method, the optical density (O. D.) method, and the screen filtration pressure (SFP) method were assessed. In summary, this method may be said to have three main points:1. It can be performed without centrifugation, avoiding mechanical stress to platelets, using only 0.8 ml. of blood and inexpensive equipment.2. It may reflect different aspects of platelet function from the O. D. method and the SFP method, despite the positive significant correlations between the values obtained by these three methods.3. It was proved to be highly reproducible and is thought to be useful clinically.By using this method, the effect of sustained isometric exercise by handgripping on platelet aggregability was assessed in coronary sclerotic and cerebral arteriosclerotic patients on placebo and EG-626, a newly synthesized cyclic AMP phosphodiesterase inhibitor. On placebo, an enhancement of platelet sensitivity was observed after isometric exercise in coronary and cerebral arteriosclerotic patients but not in healthy control subjects. The enhancement was prevented by pretreatment of EG-626, administered orally 1.5 hours prior to exercise.


2002 ◽  
Vol 722 ◽  
Author(s):  
Ram W. Sabnis ◽  
Mary J. Spencer ◽  
Douglas J. Guerrero

AbstractNovel organic, polymeric materials and processes of depositing thin films on electronics substrates by chemical vapor deposition (CVD) have been developed and the lithographic behavior of photoresist coated over these CVD films at deep ultraviolet (DUV) wavelength has been evaluated. The specific monomers synthesized for DUV applications include [2.2](1,4)- naphthalenophane, [2.2](9,10)-anthracenophane and their derivatives which showed remarkable film uniformity on flat wafers and conformality over structured topography wafers, upon polymerization by CVD. The chemical, physical and optical properties of the deposited films have been characterized by measuring parameters such as thickness uniformity, solubility, conformality, adhesion to semiconductor substrates, ultraviolet-visible spectra, optical density, optical constants, defectivity, and resist compatibility. Scanning electron microscope (SEM) photos of cross-sectioned patterned wafers showed verticle profiles with no footing, standing waves or undercut. Resist profiles down to 0.10 νm dense lines and 0.09 νm isolated lines were achieved in initial tests. CVD coatings generated 96-100% conformal films, which is a substantial improvement over commercial spin-on polymeric systems. The light absorbing layers have high optical density at 248 nm and are therefore capable materials for DUV lithography applications. CVD is a potentially useful technology to extend lithography for sub-0.15 νm devices. These films have potential applications in microelectronics, optoelectronics and photonics.


Sign in / Sign up

Export Citation Format

Share Document