Cerebral Blood Flow Monitoring via Superconductive Nanowire Single Photon Detection

Author(s):  
Nisan Ozana ◽  
Dibbyan Mazumder ◽  
Alexander I. Zavriyev ◽  
Megan Blackwell ◽  
Stefan A. Carp ◽  
...  
Instruments ◽  
2021 ◽  
Vol 5 (2) ◽  
pp. 18
Author(s):  
Fabio Acerbi ◽  
Anurag Behera ◽  
Alberto Dalla Mora ◽  
Laura Di Sieno ◽  
Alberto Gola

Silicon photomultipliers (SiPM) are pixelated single-photon detectors combining high sensitivity, good time resolution and high dynamic range. They are emerging in many fields, such as time-domain diffuse optics (TD-DO). This is a promising technique in neurology, oncology, and quality assessment of food, wood, and pharmaceuticals. SiPMs can have very large areas and can significantly increase the sensitivity of TD-DO in tissue investigation. However, such improvement is currently limited by the high detector noise and the worsening of SiPM single-photon time resolution due to the large parasitic capacitances. To overcome such limitation, in this paper, we present two single-photon detection modules, based on 6 × 6 mm2 and 10 × 10 mm2 SiPMs, housed in vacuum-sealed TO packages, cooled to −15 °C and −36 °C, respectively. They integrate front-end amplifiers and temperature controllers, being very useful instruments for TD-DO and other biological and physical applications. The signal extraction from the SiPM was improved. The noise is reduced by more than two orders of magnitude compared to the room temperature level. The full suitability of the proposed detectors for TD-DO measurements is outside the scope of this work, but preliminary tests were performed analyzing the shape and the stability of the Instrument Response Function. The proposed modules are thus fundamental building blocks to push the TD-DO towards deeper investigations inside the body.


2021 ◽  
Vol 50 (1) ◽  
pp. 20211016-20211016
Author(s):  
吴静远 Jingyuan Wu ◽  
刘肇国 Zhaoguo Liu ◽  
张彤 Tong Zhang

Science ◽  
2021 ◽  
Vol 372 (6540) ◽  
pp. 356.3-356
Author(s):  
Ian S. Osborne

1981 ◽  
Vol 1 (4) ◽  
pp. 385-389 ◽  
Author(s):  
Martin Lauritzen ◽  
Leif Henriksen ◽  
Niels A. Lassen

Regional cerebral blood flow (CBF) was studied in 16 normal adult volunteers during rest and in 10 the study was repeated during skilled hand movements. A fast-rotating (“dynamic”), single-photon emission computerized tomograph (ECT) with four detector heads was used. Xenon-133 was inhaled over a 1-min period at a concentration of 10 mCi/L. The arrival and washout of the radioisotope was recorded during four 1-min periods. Two slices, 2 cm thick, 7 and 12 cm above the orbitomeatal line were obtained in every study. CBF averaged 60 ml/100 g/min (SD ± 11) in the lower slice and 51 ml/100 g/min (SD ± 13) in the upper slice. A symmetric pattern comparing right to left sides was found in both slices. Finger tapping and writing with the right hand increased CBF in specific areas of the upper slice: in the contralateral hand area by 35 ± 15% ( p < 0.025), and in the supplementary motor area on both sides by 34 ± 15% ( p < 0.025).


Materials ◽  
2018 ◽  
Vol 11 (6) ◽  
pp. 869 ◽  
Author(s):  
Andreas Hans ◽  
Philipp Schmidt ◽  
Christian Ozga ◽  
Gregor Hartmann ◽  
Xaver Holzapfel ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document