scholarly journals Nonlinear propagation of fs laser pulses in liquids and evolution of supercontinuum generation

2005 ◽  
Vol 13 (25) ◽  
pp. 10248 ◽  
Author(s):  
Jiansheng Liu ◽  
H. Schroeder ◽  
S. L. Chin ◽  
Ruxin Li ◽  
Zhizhan Xu
Author(s):  
Paresh K Joshi ◽  
Aditya K Dharmadhikari ◽  
Jayashree A Dharmadhikari ◽  
Praful M Barvalia

We have carried out systematic studies to investigate the effect on supercontinuum generation in water using 40 fs laser pulses when doped with Homeopathic medicines. We perform these studies using five series of medications with different levels of dilution (10-30 to 10-100000). We measure supercontinuum spectra that span from 400-1050 nm. We monitor the area under the curve in the range 450-750 nm for each sample at a fixed incident laser energy. Our observations indicate that the yield of supercontinuum generation, in water containing Homeopathic medicine is significantly different from that obtained in water containing plain ethanol. The measurement for different dilutions shows up to 7 times standard deviation variation in the yield of supercontinuum generation? Even though linear absorption in the UV-visible region does not show any significant difference for different Homeopathic medicines, the supercontinuum yield which depends on the effective nonlinear refractive index changes with different samples.


2018 ◽  
Vol 57 (7) ◽  
pp. 1689 ◽  
Author(s):  
Than Singh Saini ◽  
Nguyen Phuoc Trung Hoa ◽  
Kenshiro Nagasaka ◽  
Xing Luo ◽  
Tong Hoang Tuan ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Maria Ruchkina ◽  
Dina Hot ◽  
Pengji Ding ◽  
Ali Hosseinnia ◽  
Per-Erik Bengtsson ◽  
...  

AbstractLaser-induced grating spectroscopy (LIGS) is for the first time explored in a configuration based on the crossing of two focused femtosecond (fs) laser pulses (800-nm wavelength) and a focused continuous-wave (cw) laser beam (532-nm wavelength). A thermal grating was formed by multi-photon absorption of the fs-laser pulses by $$\hbox {N}_{{2}}$$ N 2 with a pulse energy around 700 $$\upmu $$ μ J ($$\sim $$ ∼ 45 TW/$$\hbox {cm}^{2}$$ cm 2 ). The feasibility of this LIGS configuration was investigated for thermometry in heated nitrogen gas flows. The temperature was varied from room temperature up to 750 K, producing strong single-shot LIGS signals. A model based on the solution of the linearized hydrodynamic equations was used to extract temperature information from single-shot experimental data, and the results show excellent agreement with the thermocouple measurements. Furthermore, the fluorescence produced by the fs-laser pulses was investigated. This study indicates an 8-photon absorption pathway for $$\hbox {N}_{{2}}$$ N 2 in order to reach the $$\hbox {B}^{3}\Pi _{g}$$ B 3 Π g state from the ground state, and 8 + 5 photon excitation to reach the $$\hbox {B}^{2}\Sigma _{u}^{+}$$ B 2 Σ u + state of the $$\hbox {N}_{2}^{+}$$ N 2 + ion. At pulse energies higher than 1 mJ, the LIGS signal was disturbed due to the generation of plasma. Additionally, measurements in argon gas and air were performed, where the LIGS signal for argon shows lower intensity compared to air and $$\hbox {N}_{{2}}$$ N 2 .


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Sicong Wang ◽  
Chen Wei ◽  
Yuanhua Feng ◽  
Hongkun Cao ◽  
Wenzhe Li ◽  
...  

AbstractAlthough photonics presents the fastest and most energy-efficient method of data transfer, magnetism still offers the cheapest and most natural way to store data. The ultrafast and energy-efficient optical control of magnetism is presently a missing technological link that prevents us from reaching the next evolution in information processing. The discovery of all-optical magnetization reversal in GdFeCo with the help of 100 fs laser pulses has further aroused intense interest in this compelling problem. Although the applicability of this approach to high-speed data processing depends vitally on the maximum repetition rate of the switching, the latter remains virtually unknown. Here we experimentally unveil the ultimate frequency of repetitive all-optical magnetization reversal through time-resolved studies of the dual-shot magnetization dynamics in Gd27Fe63.87Co9.13. Varying the intensities of the shots and the shot-to-shot separation, we reveal the conditions for ultrafast writing and the fastest possible restoration of magnetic bits. It is shown that although magnetic writing launched by the first shot is completed after 100 ps, a reliable rewriting of the bit by the second shot requires separating the shots by at least 300 ps. Using two shots partially overlapping in space and minimally separated by 300 ps, we demonstrate an approach for GHz magnetic writing that can be scaled down to sizes below the diffraction limit.


2011 ◽  
Vol 1319 ◽  
Author(s):  
Michael J. Abere ◽  
Ryan D. Murphy ◽  
Bianca Jackson ◽  
Gerard Mourou ◽  
Michel Menu ◽  
...  

ABSTRACTAn ultrafast laser irradiation method for the removal of corrosion from Daguerreotypes without detrimentally affecting image quality has been developed. Corrosion products such as silver oxide and silver sulfide may be removed by chemical cleaning but these reactions are hard to control and are often damaging to the underlying silver, ruining the image. The Ti:Sapphire 150 fs laser pulses used in this study are focused to a beam diameter of 60 μm and are normally incident to the Daguerreotype. It was found that the corrosion layer has a lower material removal threshold than silver allowing for removal of corrosion with minimal removal of vital information contained in the silver substrate.


2012 ◽  
Vol 16 ◽  
pp. 15-20 ◽  
Author(s):  
Omid Tayefeh Ghalehbeygi ◽  
Vural Kara ◽  
Levent Trabzon ◽  
Selcuk Akturk ◽  
Huseyin Kizil

We fabricated Si Nano-columns by a femtosecond laser with various wavelengths and process parameters, whilst the specimen was submerged in water. The experiments were carried out by three types of wavelengths i.e. 1030 nm, 515nm, 343nm, with 500 fs laser pulses. The scales of these spikes are much smaller than micro spikes that are constructed by laser irradiation of silicon surface in vacuum or gases like SF6, Cl2. The Si nano-columns of 300 nm or less in width were characterized by SEM measurements. The formation of these Si Nano-columns that were revealed by SEM observation, indicates chemical etching with laser ablation occurred when surface exposed by laser beam. We observed 200 nm spikes height at the center of laser beam profile and the ones uniform in height at lateral incident area.


2005 ◽  
Vol 22 (3) ◽  
pp. 611-614 ◽  
Author(s):  
Zhu Chang-Jun ◽  
Wang Yun-Cai ◽  
Zhou Jian-Ying
Keyword(s):  

2005 ◽  
Vol 33 (2) ◽  
pp. 480-481 ◽  
Author(s):  
M. Kaluza ◽  
I.B. Foldes ◽  
E. Racz ◽  
M.I.K. Santala ◽  
G.D. Tsakiris ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document