An Improved Ion-Pair Reversed Phase LC Method for Analysis of Major Impurities of Phosphorothioate Oligonucleotide Cantide

2010 ◽  
Vol 72 (3-4) ◽  
pp. 215-223 ◽  
Author(s):  
Shu Li ◽  
Dan-Dan Lu ◽  
Yu-Lin Zhang ◽  
Sheng-Qi Wang
Bioanalysis ◽  
2021 ◽  
Vol 13 (16) ◽  
pp. 1233-1244
Author(s):  
Jennifer M Nguyen ◽  
Martin Gilar ◽  
Brooke Koshel ◽  
Michael Donegan ◽  
Jason MacLean ◽  
...  

Aim: Accurate and reliable quantification of oligonucleotides can be difficult, which has led to an increased focus on bioanalytical methods for more robust analyses. Recent advances toward mitigating sample losses on liquid chromatography (LC) systems have produced recovery advantages for oligonucleotide separations. Results & methodology: LC instruments and columns constructed from MP35N metal alloy and stainless steel columns were compared against LC hardware modified with hybrid inorganic-organic silica surfaces. Designed to minimize metal-analyte adsorption, these surfaces demonstrated a 73% increase in 25-mer phosphorothioate oligonucleotide recovery using ion-pairing reversed-phase LC versus standard LC surfaces, most particularly upon initial use. Conclusion: Hybrid silica chromatographic surfaces improve the performance, detection limits and reproducibility of oligonucleotide bioanalytical assays.


1996 ◽  
Vol 79 (6) ◽  
pp. 1281-1287 ◽  
Author(s):  
Dimitrios Fletouris ◽  
Nickos Botsoglou ◽  
Ioannis Psomas ◽  
Antonios Mantis

Abstract A simple, rapid, and sensitive liquid chromatographic (LC) assay for quantitative screening of albendazole 2-aminosulfone, albendazole sulfoxide, oxibendazole, oxfendazole, albendazole sulfone, p-hydroxyfenbendazole, albendazole, mebendazole, fenbendazole sulfone, and fenbendazole residues in milk was developed. Samples are made basic (pH 10) and extracted with ethyl acetate. Extracts are partitioned with water, evaporated to dryness, reconstituted with mobile phase, and analyzed isocratically by ion-pair reversed-phase LC at 292 nm. Overall recoveries ranged from 79 to 100%. Linearity was excellent in the fortification range examined (5.3–200 ng/mL). Precision data, based on within- and between-days variations, suggested an overall relative standard deviation of 2.0 to 5.8%. The method was successfully used to quantitate albendazole and fenbendazole and metabolites in milk from 2 drug-treated dairy cows.


2010 ◽  
Vol 30 (2) ◽  
pp. 193-195
Author(s):  
Hui WANG ◽  
Qing YE ◽  
Liang ZHAO ◽  
Wen-jun TIAN ◽  
Guo-qing ZHANG

Sign in / Sign up

Export Citation Format

Share Document