Stability and Surface Uniformity of Selected Thiol-Coated SERS Surfaces

1997 ◽  
Vol 51 (9) ◽  
pp. 1355-1359 ◽  
Author(s):  
Timothy O. Deschaines ◽  
Keith T. Carron

The use of surface-enhanced Raman scattering (SERS) as an analytical technique continues to grow, but questions about its viability remain. This paper addresses the concern about the long-term stability of the surfaces used with the SERS technique. We have studied the long-term stability of Ag surfaces coated with three different thiol compounds. For this study, we have used 1-propanethiol, 1-do-decanethiol, and p-cresolthiol to coat the Ag surfaces. These surfaces showed long-term stabilities of over a month with minimal surface degradation. In order to mimic a realistic application of SERS, we stored the coated surfaces in a solution of water. Sodium dodecylsulfate (SDS) was added to maintain consistent surface wetting conditions so that reproducible results were obtainable on a day-to-day basis. Spatial heterogeneity of the surfaces and coating was analyzed with a fiber-optic Raman system. The spatial heterogeneity of the surfaces explains the day-to-day variations observed in the detection when the same portion of the surface used for analysis varies from day to day.

Sensors ◽  
2019 ◽  
Vol 19 (5) ◽  
pp. 1203 ◽  
Author(s):  
Nannan Shen ◽  
Haijun Xu ◽  
Weichen Zhao ◽  
Yongmei Zhao ◽  
Xin Zhang

Glucose concentration is an important physiological index, therefore methods for sensitive detection of glucose are important. In this study, Au foam was prepared by electrodeposition with a dynamic gas template on an Au nanoparticle/Si substrate. The Au foam showed ultrasensitivity, high selectivity, and long-term stability in the quantitative detection of glucose. The foam was used as an electrode, and the amperometric response indicated excellent catalytic activity in glucose oxidation, with a linear response across the concentration range 0.5 μM to 12 mM, and a limit of detection of 0.14 μM. High selectivity for interfering molecules at six times the normal level and long-term stability for 30 days were obtained. The results for electrochemical detection with Au foam of glucose in human serum were consistent with those obtained with a sensor based on surface-enhanced Raman spectroscopy and a commercial sensor. This proves that this method can be used with real samples. These results show that Au foam has great potential for use as a non-enzymatic glucose sensor.


2016 ◽  
Vol 8 (2) ◽  
pp. 425-438 ◽  
Author(s):  
Alexander Loew ◽  
Ralf Bennartz ◽  
Frank Fell ◽  
Alessio Lattanzio ◽  
Marie Doutriaux-Boucher ◽  
...  

Abstract. Validating the accuracy and long-term stability of terrestrial satellite data products necessitates a network of reference sites. This paper documents a global database of more than 2000 sites globally which have been characterized in terms of their spatial heterogeneity. The work was motivated by the need for potential validation sites for geostationary surface albedo data products, but the resulting database is useful also for other applications. The database (SAVS 1.0) is publicly available through the EUMETSAT website (http://savs.eumetsat.int/, doi:10.15770/EUM_SEC_CLM_1001). Sites can be filtered according to different criteria, providing a flexible way to identify potential validation sites for further studies and a traceable approach to characterize the heterogeneity of these reference sites. The present paper describes the detailed information on the generation of the SAVS 1.0 database and its characteristics.