scholarly journals Fundal Height as a Predictor of Early Preterm Triplet Delivery

Twin Research ◽  
2002 ◽  
Vol 5 (2) ◽  
pp. 71-74 ◽  
Author(s):  
Yoshie Yokoyama

AbstractThe purpose of this study was to create graphs of fundal height parameters in triplet pregnancies compared with those in twin pregnancies, and to investigate whether larger fundal heights in triplet pregnancies would predispose them to earlier delivery (before 34 weeks). The subjects were 727 twin pregnant women and 133 triplet pregnant women, who delivered after 1984. Triplet pregnancies showed significantly higher fundal heights compared with twin pregnancies at each gestational age (weeks). In triplet pregnancies, a single fundal height measurement above the 90th percentile before 34 weeks yielded a sensitivity of 31.3% and specificity of 82.4% for delivery before 34 weeks, with a positive predictive value of 50.0% and a negative predictive value of 68.0%. After adjusting for each associated factor using logistic regression, the risk of preterm labour was not significantly associated with a single fundal height measurement above the 90th percentile recorded before 34 weeks.

2012 ◽  
Vol 69 (6) ◽  
pp. 492-499 ◽  
Author(s):  
Brankica Vasiljevic ◽  
Svjetlana Maglajlic-Djukic ◽  
Miroslava Gojnic

Background/Aim. Diagnosis of perinatal hypoxic-ischemic encephalopathy (HIE) and early prediction neurological outcome is important and difficult. The aim of this study was to determine the prognostic value of amplitude integrated electroencephalography (aEEG) for abnormal neurodevelopment outcome in a neonate with HIE. Methods. A total of 90 neonates > 32 gestational age (GA) with HIE were enrolled prospectively. All neonates with HIE were categorized into three grades according to the Sarnat and Sarnat clinical scoring system (mild HIE, moderate HIE and severe HIE). aEEG traces were recorded with a cerebral function monitor (CFM) during the first 72 h of life. The neurodevelopment outcome was assessed at 12 months of age of corrected gestational age. Results. The pattern of aEEG correlated with the severity of HIE (p < 0.0001) and subsequent neurodevelopment outcome (p < 0.001). We found that aEEG background patterns exhibited superior prediction of abnormal outcomes at 12 months of age (sensitivity of 91.7% and specificity of 94.3%, positive predictive value of 78.6% and negative predictive value of 98.1%) when compared to aEEG seizure (sensitivity of 94% and specificity of 48%, positive predictive value of 57% and a negative predictive value of 92%). Electroclinical dissociation seizure was detected in 28% of the neonates with HIE. Conclusions. Our results confirm that aEEG is simple and accurate bedside diagnostic method for assessing extension of hypoxic-ischemic brain damage and early identification of neonates with perinatal HIE who are at high risk of neurodevelopmental impairment.


2007 ◽  
Vol 10 (1) ◽  
pp. 198-201 ◽  
Author(s):  
Rita C. A. Machado ◽  
Maria L. Brizot ◽  
Adolfo W. Liao ◽  
Fábio R. Cabar ◽  
Marcelo Zugaib

AbstractOur aim was to evaluate the ability of prenatal ultrasound scans to predict fetal growth discordance, and to examine the correlation between fetal weight estimated by ultrasound with actual birthweight in twin pregnancies. The study consisted of 221 twin pregnancies with ultrasound fetal weight estimates based on Hadlock's 4 parameter formula. Prediction of intertwin birthweight discordance was examined at 4 different intervals between ultrasound examination and delivery (0–7 days, n = 96; 8–14 days, n = 66; 15–21 days, n = 58; 22–28 days, n = 59 pregnancies), with a total of 279 ultrasound examinations. Birthweight discordance was considered as a difference of 20% or greater. The correlation between fetal weight estimated between 0 and 7 days and actual birthweight was calculated by intraclass correlation coefficient. The predictive values for intertwin discordance of 20% or more in the 0 to 7 days group were: sensitivity = 93.6%, specificity = 79.4%, positive predictive value = 89.2%, negative predictive value = 87.1% and accuracy = 88.6%. In the groups with scans carried out between 8 and 14 days, 15 and 21 days, and 22 and 28 days, the sensitivity and accuracy values were 95.8% and 84.9%, 95.6% and 84.5%, 90.9% and 84.8%, respectively. Fetal growth discordance in twins can be accurately predicted by ultrasound examination performed up to 28 days before birth. There is a good correlation between fetal weight estimated between 0 and 7 days and actual birthweight.


Author(s):  
Imee Surbakti ◽  
Adi Koesoema Aman ◽  
Makmur Sitepu

Varieties of the laboratory test can be applied in the detecting of iron status. These test are divided into conventional hematologic index and biochemical iron serum. With the development of an hematological analyzer, new parameter has been found to monitor theiron status with reticulocytes hemoglobin analysis (Ret-He). To know the diagnostic accuracy of Ret-He and to conclude whether Ret-He can be used as a parameter to detect iron deficiency in pregnant women by obtaining certain information. This study used analyticalcross sectional was conducted at Haji Adam Malik Hospital Medan, in March-June 2013. The Applying samples consisted of 64 third trimester pregnant women which divided into two (2) groups: the noniron deficiency group using 28 subjects and in the iron deficiency 36 subjects. In this study, the researchers found AUC for Ret-He about 77.7% with the best cut off value of <31.4 pg. Using the cut off value the researchers obtained the sensitivity about 61.1%, specificity 75.0%, Positive Predictive Value (PPV) 75.8%, Negative Predictive Value (NPV) 60.0%, Likehood Ratio (LR) (+) 2.44 and LR (–) 0.51%. Based on this study, can be concluded, that the diagnostic accuracy Ret-He is a good parameter to detect iron deficiency in the pregnant women


2019 ◽  
Vol 10 (5) ◽  
pp. 98-101
Author(s):  
Gyawali Merina ◽  
Poudel Ramesh

Background: Doppler provides assessment of uteroplacental and fetoplacental circulation during pregnancy. It is a sensitive tool in early detection of fetal compromise and allows needful intervention. Aims and Objective: To study the role of umbilical artery doppler in clinically suspected IUGR and its implication on neonatal outcome. Materials and Methods: A total of 104 singleton pregnancies with gestational age of more than 34 weeks who had clinical suspicion of IUGR were evaluated using obstetric ultrasound and doppler. Umbilical arteryvelocimetry with S/D >3 and RI >0.7 were considered abnormal. Newborns were classified as either small for gestational age (SGA) ie, IUGR or appropriate for gestational age (AGA). Neonatal outcome were classified as either normal or adverse events that included still birth, NICU admissions, perinatal asphyxia and/or neonatal death. Results: Out of 104 clinically suspected IUGR, 55 were born with small for gestational age. Among these SGA neonates, 45 subjects had abnormal umbilical artery S/D and 42 had abnormal RI. Abnormal umbilicalartery S/D ratio had a sensitivity of 81.8 %, specificity of 59.2 %, the positive predictive value of 69.2 % and negative predictive value of 74.4 %. Abnormal Umbilical artery RI had a sensitivity of 76.4 %, specificity of 69.4 %, positive predictive value of 73.7 % and negative predictive value of 72.3 % in diagnosing IUGR. Abnormal umbilical artery velocimetry was associated with increased morbidity and mortality in IUGR neonates. Conclusions: Umbilical artery doppler plays an important role in diagnosing IUGR and predicting neonatal outcome.


Author(s):  
Youssriah Yahia Sabri ◽  
Ikram Hamed Mahmoud ◽  
Lamis Tarek El-Gendy ◽  
Mohamed Raafat Abd El-Mageed ◽  
Sally Fouad Tadros

Abstract Background There are many causes of pleural disease including variable benign and malignant etiologies. DWI is a non-enhanced functional MRI technique that allows qualitative and quantitative characterization of tissues based on their water molecules diffusivity. The aim of this study was to evaluate the diagnostic value of DWI-MRI in detection and characterization of pleural diseases and its capability in differentiating benign from malignant pleural lesions. Results Conventional MRI was able to discriminate benign from malignant lesions by using morphological features (contour and thickness) with sensitivity 89.29%, specificity 76%, positive predictive value 89%, negative predictive value 76.92%, and accuracy 85.37%. ADC value as a quantitative parameter of DWI found that ADC values of malignant pleural diseases were significantly lower than that of benign lesions (P < 0.001). Hence, we discovered that using ADC mean value of 1.68 × 10-3 mm2/s as a cutoff value can differentiate malignant from benign pleural diseases with sensitivity 89.3%, specificity 100%, positive predictive value 100%, negative predictive value 81.2%, and accuracy 92.68% (P < 0.001). Conclusion Although DWI-MRI is unable to differentiate between malignant and benign pleural effusion, its combined morphological and functional information provide valid non-invasive method to accurately characterize pleural soft tissue diseases differentiating benign from malignant lesions with higher specificity and accuracy than conventional MRI.


2021 ◽  
pp. 003335492110084
Author(s):  
Kirsten Vannice ◽  
Julia Hood ◽  
Nicole Yarid ◽  
Meagan Kay ◽  
Richard Harruff ◽  
...  

Objectives Up-to-date information on the occurrence of drug overdose is critical to guide public health response. The objective of our study was to evaluate a near–real-time fatal drug overdose surveillance system to improve timeliness of drug overdose monitoring. Methods We analyzed data on deaths in the King County (Washington) Medical Examiner’s Office (KCMEO) jurisdiction that occurred during March 1, 2017–February 28, 2018, and that had routine toxicology test results. Medical examiners (MEs) classified probable drug overdoses on the basis of information obtained through the death investigation and autopsy. We calculated sensitivity, positive predictive value, specificity, and negative predictive value of MEs’ classification by using the final death certificate as the gold standard. Results KCMEO investigated 2480 deaths; 1389 underwent routine toxicology testing, and 361 were toxicologically confirmed drug overdoses from opioid, stimulant, or euphoric drugs. Sensitivity of the probable overdose classification was 83%, positive predictive value was 89%, specificity was 96%, and negative predictive value was 94%. Probable overdoses were classified a median of 1 day after the event, whereas the final death certificate confirming an overdose was received by KCMEO an average of 63 days after the event. Conclusions King County MEs’ probable overdose classification provides a near–real-time indicator of fatal drug overdoses, which can guide rapid local public health responses to the drug overdose epidemic.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Abd El-Fattah F. Hanno ◽  
Fatma M. Abd El-Aziz ◽  
Akram A. Deghady ◽  
Ehab H. El-Kholy ◽  
Aborawy I. Aborawy

Abstract Background Liver cancer is the fifth most common cancer and the second most frequent cause of cancer-related death globally. Early stages of hepatocellular carcinoma (0&A) can be treated with curative procedures. The aim of this work was to evaluate the role of annexin A2 and osteopontin for early diagnosis of hepatocellular carcinoma in hepatitis C virus patients. Methods The study was carried out on 80 patients classified into two groups. Group A had 40 chronic hepatitis C patients without hepatocellular carcinoma, while group B had 40 chronic hepatitis C patients with early hepatocellular carcinoma (stages; 0&A). All patients were subjected to thorough history taking, clinical examination, liver function tests, renal function tests, serum alpha-fetoprotein, serum osteopontin, and serum annexin A2. Results Serum alpha-fetoprotein was found to be statistically significantly higher in patients with the hepatocellular carcinoma group than the chronic hepatitis C group. The ROC curve for alpha-fetoprotein for detection of HCC was significant, its diagnostic performance was 0.818* (p < 0.001*), and the cutoff point for predicting the probability for HCC was 6.0 (ng/ml) with sensitivity of 77.50%, specificity of 82.50%, positive predictive value of 81.60%, negative predictive value of 78.6%, and accuracy of 80%. Serum osteopontin was found to be statistically significantly higher in patients from the hepatocellular carcinoma group than the chronic hepatitis C group. The ROC curve for osteopontin was significant, its diagnostic performance was 0.739* (p < 0.001*), the cutoff point was 13.2 (ng/ml) with sensitivity of 65.0%, specificity of 90.0%, positive predictive value of 86.70%, negative predictive value of 72.0%, and accuracy of 77.0%. Serum annexin A2 was found to be statistically significantly higher in patients from the hepatocellular carcinoma group than the chronic hepatitis C group. The ROC curve for annexin A2 was significant, its diagnostic performance was 0.927* (p < 0.001*), the cutoff point was 10.1(ng/ml) with sensitivity of 85.0%, specificity of 85.0%, positive predictive value of 85.0%, negative predictive value of 85.0%, and accuracy of 85.0%. Conclusions Osteopontin had better specificity but lower sensitivity than serum alpha-fetoprotein for early diagnosis of hepatocellular carcinoma. Annexin A2 had better diagnostic sensitivity and specificity than alpha-fetoprotein for early diagnosis of hepatocellular carcinoma.


2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 602.1-603
Author(s):  
E. S. Torun ◽  
E. Bektaş ◽  
F. Kemik ◽  
M. Bektaş ◽  
C. Cetin ◽  
...  

Background:Recently developed EULAR/ACR classification criteria for systemic lupus erythematosus (SLE) have important differences compared to the 2012 Systemic Lupus International Collaborating Clinics (SLICC) SLE classification criteria and the revised 1997 American College of Rheumatology (ACR) criteria: The obligatory entry criterion of antinuclear antibody (ANA) positivity is introduced and a “weighted” approach is used1. Sensitivity and specificity of these three criteria have been debated and may vary in different populations and clinical settings.Objectives:We aim to compare the performances of three criteria sets/rules in a large cohort of patients and relevant diseased controls from a reference center with dedicated clinics for SLE and other autoimmune/inflammatory connective tissue diseases from Turkey.Methods:We reviewed the medical records of SLE patients and diseased controls for clinical and laboratory features relevant to all sets of criteria. Criteria sets/rules were analysed based on sensitivity, positive predictive value, specificity and negative predictive value, using clinical diagnosis with at least 6 months of follow-up as the gold standard. A subgroup analysis was performed in ANA positive patients for both SLE patients and diseased controls. SLE patients that did not fulfil 2012 SLICC criteria and 2019 EULAR/ACR criteria and diseased controls that fulfilled these criteria were evaluated.Results:A total of 392 SLE patients and 294 non-SLE diseased controls (48 undifferentiated connective tissue disease, 51 Sjögren’s syndrome, 43 idiopathic inflammatory myopathy, 50 systemic sclerosis, 52 primary antiphospholipid syndrome, 15 rheumatoid arthritis, 15 psoriatic arthritis and 20 ANCA associated vasculitis) were included into the study. Hundred and fourteen patients (16.6%) were ANA negative.Sensitivity was more than 90% for 2012 SLICC criteria and 2019 EULAR/ACR criteria and positive predictive value was more than 90% for all three criteria (Table 1). Specificity was the highest for 1997 ACR criteria. Negative predictive value was 76.9% for ACR criteria, 88.4% for SLICC criteria and 91.7% for EULAR/ACR criteria.In only ANA positive patients, sensitivity was 79.6% for 1997 ACR criteria, 92.2% for 2012 SLICC criteria and 96.1% for 2019 EULAR/ACR criteria. Specificity was 92.6% for ACR criteria, 87.8% for SLICC criteria 85.2% for EULAR/ACR criteria.Eleven clinically diagnosed SLE patients had insufficient number of items for both 2012 SLICC and 2019 EULAR/ACR criteria. Both criteria were fulfilled by 16 diseased controls: 9 with Sjögren’s syndrome, 5 with antiphospholipid syndrome, one with dermatomyositis and one with systemic sclerosis.Table 1.Sensitivity, positive predictive value, specificity and negative predictive value of 1997 ACR, 2012 SLICC and 2019 EULAR/ACR classification criteriaSLE (+)SLE (-)Sensitivity (%)Positive Predictive Value (%)Specificity (%)Negative Predictive Value (%)1997 ACR(+) 308(-) 841527978.695.494.976.92012 SLICC(+) 357(-) 352626891.193.291.288.42019 EULAR/ACR(+) 368(-) 242826693.892.990.591.7Conclusion:In this cohort, although all three criteria have sufficient specificity, sensitivity and negative predictive value of 1997 ACR criteria are the lowest. Overall, 2019 EULAR/ACR and 2012 SLICC criteria have a comparable performance, but if only ANA positive cases and controls are analysed, the specificity of both criteria decrease to less than 90%. Some SLE patients with a clinical diagnosis lacked sufficient number of criteria. Mostly, patients with Sjögren’s syndrome or antiphospholipid syndrome are prone to misclassification by both recent criteria.References:[1]Aringer M, Costenbader K, Daikh D, et al. 2019 European League Against Rheumatism/American College of Rheumatology classification criteria for systemic lupus erythematosus. Ann Rheum Dis 2019;78:1151-1159.Disclosure of Interests:None declared


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Moshage ◽  
S Smolka ◽  
S Achenbach ◽  
F Ammon ◽  
P Ferstl ◽  
...  

Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (proximal vs. distal vessel segments) compared to invasively measured FFR in patients with suspected CAD. Methods A total of 136 vessels in which “Dual-Source”-CT coronary angiography had been performed due to suspected CAD and who were further referred for invasive coronary angiography with invasive FFR measurement within three months of the index CT examination were retrospectively identified and screened for inclusion in this analysis. Patients with either left main coronary artery stenoses, bifurcation or ostial stenoses were excluded. Invasive FFR was measured using a pressure wire (CERTUS®, St. Jude Medical, Minnesota, USA or Verrata®, Volcano, San Diego, USA). FFRCT was calculated using an on-site prototype (cFFR Version 3.0, Siemens Healthineers, Forchheim, Germany). All vessels were analyzed by an experienced observer blinded to the results of invasive FFR. Stenoses with invasively measured FFR ≤0.80 were classified as hemodynamically significant. We evaluated the diagnostic accuracy of FFRCT in proximal vs. non-proximal vessel segments. Proximal lesions included stenoses located in segment one, six, eleven and twelve. All other stenoses were categorized as distal lesions. Results Out of 136 coronary stenoses, 47 (35%) were located in proximal segments and 89 (65%) lesions were located in distal segments. Compared to invasive FFR, the sensitivity of FFRCT to correctly identify/exclude hemodynamically significant stenoses in proximal vessel segments was 93% (95% CI: 68–99.8%) and the specificity was 100% (95% CI: 89–100%), compared to a sensitivity of 72% (95% CI: 46.5–90%) and a specificity of 87% (95% CI: 77–94%) for FFRCT in distal lesions. The positive predictive value was 100% and the negative predictive value was 97% (95% CI: 82.8–99.5%) compared to a positive predictive value of 59% (95% CI: 42–93.9%) and a negative predictive value of 93% (95% CI: 85.4–96.3%) for proximal vs. distal vessel segment, respectively. This corresponds to an accuracy of 98% vs. 84%, respectively (p=0.02). ROC-Curve analysis showed a slightly higher – albeit non-significant – area under the curve for FFRCT to detect hemodynamic relevance in proximal lesions compared to distal lesions (AUC 0.95, p&lt;0.001 vs. AUC: 0.86, p&lt;0.001, respectively, p=0.2). Conclusion FFRCT obtained using an on-site prototype shows overall a high diagnostic accuracy for detecting lesions causing ischemia as compared to invasive FFR with a trend towards better diagnostic performance in proximal vessel segments. Funding Acknowledgement Type of funding source: None


Medicina ◽  
2021 ◽  
Vol 57 (5) ◽  
pp. 503
Author(s):  
Thomas F. Monaghan ◽  
Syed N. Rahman ◽  
Christina W. Agudelo ◽  
Alan J. Wein ◽  
Jason M. Lazar ◽  
...  

Sensitivity, which denotes the proportion of subjects correctly given a positive assignment out of all subjects who are actually positive for the outcome, indicates how well a test can classify subjects who truly have the outcome of interest. Specificity, which denotes the proportion of subjects correctly given a negative assignment out of all subjects who are actually negative for the outcome, indicates how well a test can classify subjects who truly do not have the outcome of interest. Positive predictive value reflects the proportion of subjects with a positive test result who truly have the outcome of interest. Negative predictive value reflects the proportion of subjects with a negative test result who truly do not have the outcome of interest. Sensitivity and specificity are inversely related, wherein one increases as the other decreases, but are generally considered stable for a given test, whereas positive and negative predictive values do inherently vary with pre-test probability (e.g., changes in population disease prevalence). This article will further detail the concepts of sensitivity, specificity, and predictive values using a recent real-world example from the medical literature.


Sign in / Sign up

Export Citation Format

Share Document