scholarly journals High-performance liquid chromatographic detection of selected phenolic acidsin wine

2021 ◽  
Vol 9 (2) ◽  
Author(s):  
Darinka Brodnjak Vončina ◽  
Maša Islamčivic Razboršek ◽  
Marjana Simonič

The aim of this study was to develop a method for identification and quantification of phenolic acids in different wine samples. The simple reversed-phase HPLC-UV method for simultaneous determination of p-coumaric and ferulic acid was developed. The method was validated and working range, linearity, repeatability, accuracy, limit of quantitation LOQ and limit of detection LOD were determined. The linearity of the method was tested in concentration ranges 0.1-1 mg L-1 and 1-10 mg L-1. The correlation coefficients (r2) were greater than 0.996 and quality coefficients (QC) ≤ 5%. Detection limit for both compounds was 0.01 mg L-1. The method is precise (RSD

2019 ◽  
Vol 31 (5) ◽  
pp. 1002-1008
Author(s):  
Somana Siva Prasad ◽  
G.V. Krishna Mohan ◽  
A. Naga Babu

A novel reversed-phase high performance liquid chromatographic (HPLC) technique for the determination of everolimus (Isomer-B) and its impurities in the tablet dosage form has been optimized using analytical quality by design (QbD) approach. All the compounds are monitored with the photodiode array (PDA) detector at 280 nm and the parameters namely; precision, accuracy, specificity, stability, linearity, limit of quantitation (LOQ) and limit of detection (LOD) are evaluated. The quantitation limits of IMP-A, IMP-B, IMP-C, IMP-D, IMP-E, Sirolimus and TGR are found to be 0.08, 0.08, 0.10, 0.10, 0.10, 0.08 and 0.08, respectively. Recovery studies from 0.9 mg/L to 9.0 mg/L are performed for all impurities and the values were obtained between 85-110 %. Injection volume and test concentrations have been optimized to achieve LOQ values under the reporting threshold. The whole technique is developed and validated as per International Council for Harmonization (ICH) guidelines. The proposed method is robust, sensitive, rapid and successful and helpful in the regions where regulatory agencies recommend HPLC analytical method.


2009 ◽  
Vol 63 (6) ◽  
Author(s):  
Hong Yan ◽  
Pei Xu ◽  
Hai Huang ◽  
Juan Qiu

AbstractA pre-column derivatized high-performance liquid chromatographic (HPLC) method with ultraviolet-visible detection was developed to measure the concentrations of spectinomycin in fermentation broth. Derivatization reagents, 2,4-dinitrophenylhydrazine in acetonitrile (5 mg mL−1) and trifluoroacetic acid in acetonitrile (0.8 mol L−1), were added to an aliquot of the fermentation broth, and the mixture was incubated for 60 min at 70°C. The resulting derivative was separated from other compounds by isocratic elution in a reversed-phase column Zorbax SB-C18 (250 mm × 4.6 mm, 5 µm). Mobile phase consisted of acetonitrile, tetrahydrofuran, and water (φ r = 40: 35: 25) and the flow rate was 1.0 mL min−1. The detection wavelength was 415 nm. The standard curve for spectinomycin sulfate was linear with correlation coefficients of 0.9997 in the range of 25 µg mL−1 to 600 µg mL−1. The relative standard deviation values ranged from 0.43 % to 2.18 % depending on the concentration of samples. The average recovery was 101.5 %. The limit of detection was 50 ng mL−1.


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


1977 ◽  
Vol 23 (11) ◽  
pp. 1984-1988 ◽  
Author(s):  
A M Krstulovic ◽  
P R Brown ◽  
D M Rosie ◽  
P B Champlin

Abstract Concentrations of total tryptophan were determined rapidly and sensitively in 50 microliter of serum by a reversed-phase partition version of high-performance liquid chromatography. For determination of total tryptophan, sample preparation requires only precipitation of the serum protein with trichloroacetic acid and removing excess trichloroacetic acid with a 1,1,2-trichlorotrifluoroethane(Freon)/tri-N-octylamine solution. Tryptophan in serum samples was detected by ultraviolet and fluorescence spectrometry. No interferences from the naturally occurring constituents of serum were observed. Elution time for tryptophan is 15 min, the limit of detection is 1 pmol.


1982 ◽  
Vol 28 (8) ◽  
pp. 1784-1787 ◽  
Author(s):  
J Lehmann ◽  
H L Martin

Abstract Tocopherols extracted from plasma with methanol or from platelets with chloroform/methanol were injected in methanol on a reversed-phase (C18) "high-performance" liquid-chromatographic column and eluted with water/methanol (2/98, by vol) at a flow rate of 1.4 mL/min. A "high-performance" spectrophotofluorometer was used for detection. Analytical recoveries ranged from 89 to 106%. The response was linear to at least 0.3 micrograms of either tocopherol (alpha- or gamma-) applied to the column, and the limit of detection was 0.1 ng. The method was used to measure tocopherols in plasma and platelets from human subjects, and some values are presented.


2013 ◽  
Vol 10 (3) ◽  
pp. 1014-1022
Author(s):  
Baghdad Science Journal

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml respectively. The method was validated for its linearity, precision and accuracy .The proposed method was successfully applied for the determination of guaifenesin in syrups and industrial effluent samples.


2008 ◽  
Vol 91 (1) ◽  
pp. 52-58 ◽  
Author(s):  
Jlia Menegola ◽  
Martin Steppe ◽  
Elfrides E S Schapoval

Abstract Column high-performance liquid chromatographic (LC) and UV spectrophotometric methods for the quantitative determination of citalopram, a potent and selective serotonin reuptake inhibitor, in tablets were developed. The parameters linearity, precision, accuracy, specificity, robustness, limit of detection, and limit of quantitation were studied according to International Conference on Harmonization guidelines. Chromatography was carried out by the reversed-phase technique on an ACE C18 column with a mobile phase composed of 0.30 triethylamine solutionacetonitrile (55 + 45, v/v) adjusted to pH 6.6 with 10 ortho-phosphoric acid at a flow rate of 1.0 mL/min and 25C. The UV spectrophotometric method was performed at 239 nm. The linearity of the LC method was in the range of 10.0070.00 g/mL, and 2.5017.50 g/mL for the UV spectrophotometric method. The interday and intraday assay precision was <1.5 (relative standard deviation) for the LC and UV spectrophotometric methods. The recoveries were in the range 100.70101.35 for the LC method and 98.4898.65 for the UV spectrophotometric method. Statistical analysis by Student's t-test showed no significant difference between the results obtained by the 2 methods. The proposed methods are highly sensitive, precise, and accurate and can be used for the reliable quantitation of citalopram in tablets.


1983 ◽  
Vol 29 (10) ◽  
pp. 1840-1842 ◽  
Author(s):  
J Lehmann ◽  
H L Martin

Abstract We have adapted to erythrocytes a method for the determination of alpha- and gamma-tocopherols in plasma and platelets. Erythrocytes (50 microL) were extracted with methanol containing tocol (internal standard) and pyrogallol. Tocopherols were partitioned into chloroform, washed, and injected in methanol onto a reversed-phase (C18) "high-performance" liquid-chromatographic column. The mobile phase was methanol/water (99/1 by vol) at a flow rate of 2 mL/min and detection was with a "high-performance" spectrophotofluorometer. The limit of detection for either tocopherol is 0.10 microgram/mL of packed cells. Analytical recoveries ranged from 93 to 104%. Some values for tocopherols in human erythrocytes are presented.


2009 ◽  
Vol 92 (3) ◽  
pp. 773-778 ◽  
Author(s):  
Juan Chen ◽  
Xue-Mei Ma ◽  
Yan-Ping Shi

Abstract A high-performance liquid chromatographic technique coupled with photodiode array detection was proposed for the simultaneous determination of 7 flavonoids, i.e., quercetin, kaempferol, 7-hydroxyflavanone, 7-methoxyflavanone, 2,4-dihydroxychalcone, 2,4-dihydroxydihydrochalcone, and 7,2-dihydroxy-3, 4-dimethoxyisoflavane, in extracts of the plant Ixeridium gracile. Optimum separation was obtained by using a reversed-phase C18 method. Because of the different UV characteristics of these components, 5 detection wavelengths were used for the quantitative analysis. All of the flavonoids showed good linearity (r > 0.9999). The limit of detection and limit of quantitation values for the analytes ranged from 0.06 to 0.46 g/mL and from 0.18 to 1.48 g/mL, respectively. The method was validated by evaluating repeatability, precision, stability, and accuracy. Five different extraction and purification procedures were investigated for preparation of the sample solution. The optimized method was applied to the determination of flavonoids in I. gracile and was found to be efficient.


Sign in / Sign up

Export Citation Format

Share Document