scholarly journals METHOD DEVELOPMENT AND VALIDATION OF LOPINAVIR IN TABLET DOSAGE FORM USING REVERSED-PHASE HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY

Author(s):  
Sunkara Namratha ◽  
Vijayalakshmi A

Objective: Reversed-phase high-performance liquid chromatographic method (RP-HPLC) was developed for the assessment of lopinavir in the dosage form of tablet.Methods: Chromatogram was run through using Kromosil C18 4.5×150 mm using a mobile phase methanol: water of ratio 65:35% v/v with a rate of flow of 0.8 ml/min, measured by UV spectrometric detection at 265 nm. The method developed was validated in terms of precision, accuracy, linearity, and robustness parameters.Results: Retention time of lopinavir established at 2.482 min and percentage R.S.D of lopinavir found to be 1.0% and 0.5%, respectively. The method shows that good linearity range of 30–150 μg correlation coefficient of lopinavir was 0.997. The limit of detection was 2.97 and limit of quantification was 9.92, respectively. The percent purity of lopinavir was 99.87%.Conclusion: The suggested method (Rp-HPLC) for concurrent assay lopinavir was validated, which is appropriate method for the analysis oflopinavir quantitatively in tablet dosage forms and bulk.

INDIAN DRUGS ◽  
2019 ◽  
Vol 56 (02) ◽  
pp. 39-46
Author(s):  
Babu D. China ◽  
◽  
C. Madhusudhana Chetty ◽  
Sk. Mastanamma

A simple, accurate, precise and robust reversed phase high performance liquid chromatographic (RP-HPLC) method was developed for the estimation of Ertugliflozin (ETZ) and metformin (MFN) in bulk and in tablet dosage form. The method was carried out by used Waters (5μm, C18 250 x 4.6 mm) column with mobile phase consists of 0.75 mM sodium dihydrogen orthophosphate buffer pH adjusted to 8.5, with NaOH, and acetonitrile in the ratio of 60:40 v/v, a flow rate of 1.5 mL/min and photodiode detection at 263 nm. The method was validated as per ICH guidelines with different parameters, the mean retention times of ertugliflozin and metformin were found to be 3.5& 2.0 min, respectively. The correlation coefficient values of calibration curves were found to be 0.999 for both ETZ and MFN, respectively. The LOD and LOQ for ertugliflozin and metformin were found to be 0.02-0.06 μg/mL and 17.5-58.3 μg/mL respectively.


2012 ◽  
Vol 10 (2) ◽  
pp. 67-70
Author(s):  
Abdullah Al Masud ◽  
Mohammad Saydur Rahman ◽  
Towfika Islam ◽  
Saki Sultana ◽  
Moynul Hasan ◽  
...  

A simple, reproducible and efficient reversed phase high performance liquid chromatographic (RPHPLC) method has been developed for the estimation of a recently approved anti allergic drug, amlexanox in oral paste dosage form. The separations were carried out on a Zorbax Eclipse XBD, C18 column (150 x 4.6 mm; 5?m) at a flow rate of 1.50 ml/min. by using mobile phase comprising of mixed buffer (pH adjusted to 6.50) and methanol (50:50 v/v). The injection volume was 10 ?l and the peaks were detected at 244 nm. The linear dynamic range found to be in the concentration range of 15-35 ?g/ml and coefficient of correlation was found to be 0.999. The %RSD value was below 2.0 for intra-day and inter-day precision which indicated that the method was highly precise. The LOD (Limit of detection) and LOQ (Limit of quantitation) were found to be 3.8 ng/ml and 12.5 ng/ml, respectively which revealed that the method was highly sensitive. The percentage recovery of amlexanox ranged from 99.31 to 99.75%, indicating the accuracy of the method and absence of interference from the excipients present in the formulation. The proposed method was simple, fast, accurate and reproducible and hence can be applied for routine quality control operations of amlexanox in oral paste dosage form. Key words: Amlexanox, Anti allergic, RP-HPLC, LOD, LOQ. DOI: http://dx.doi.org/10.3329/dujps.v10i2.11782 Dhaka Univ. J. Pharm. Sci. 10(2): 67-70, 2011 (December)


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (01) ◽  
pp. 76-78
Author(s):  
Kailasa Mangasree ◽  
◽  
Biswabara Roy ◽  
Harunrasheed Shaik ◽  
Manjunath S. Yalagatti ◽  
...  

A reverse phase high performance liquid chromatographic method was developed for simultaneous estimation of gemcitabine and clarithromycin in bulk and tablet dosage form. The method was developed by using acetonitrile: methanol: 50 mM sodium acetate buffer (adjusted to pH-3 with orthophosphoric acid (40:40:20) as a mobile phase at the flow rate of 1mL/min. The retention time was found to be 2.365 and 5.999 minutes, respectively. The method showed linearity in the concentration range 10-50 µg/mL in respect of both drugs. The % RSD was less than 0.4% for gemcitabine and 0.2% for clarithromycin. Mean percentage recovery was found to be 99.63 and 99.69 for gemcitabine and clarithromycin. The tailing factor for gemcitabine and clarithromycin was not less than 0.9 and not more than 1.4 during the robustness study. The average percentage assay was calculated and found to be 99.83 for gemcitabine and 98.89 for charithromycin. The limit of detection and quantification for gemcitabine was found to be 0.41 and 1.79 µg/mL. For Clarithromycin, the value was 0.58 and 1.37 µg/mL respectively.


2019 ◽  
Vol 11 (1) ◽  
pp. 216 ◽  
Author(s):  
Ramya Kuber B.

Objective: To develop a simple, sensitive, specific, accurate reverse phase high performance liquid chromatographic (RP-HPLC) method for the estimation of curcumin and piperine.Methods: The separation was done using a column Inertsil–ODS C18 (250 mm × 4.6 mm, 5µ particle size) and mobile phase composed of methanol: water (45:55 v/v), flow rate at 1 ml/min and detection was carried out at 282 nm with photodiode array (PDA) detector.Results: The separation of curcumin and piperine were found to be at the retention time of 2.433 min and 3.095 min, respectively. The method was found to be linear at a concentration range 20-80 µg/ml for curcumin and piperine. The limit of detection (LOD) and limit of quantification (LOQ) was found to be 0.05µg/ml and 0.17µg/ml for curcumin and 0.18µg/ml and 0.53µg/ml for piperine respectively. The average percentage recoveries of curcumin and piperine were in the range of 98-100.6%.Conclusion: A simple and sensitive reverse phase high performance liquid chromatographic method was developed for the estimation of curcumin and piperine.


Author(s):  
Amruta A. Chaudhary ◽  
Ashwini V. Shelke ◽  
Anil G. Jadhav

A specific, accurate rp-HPLC (reversed-phase high performance liquid chromatographic) method was developed for the quantification of Cabozantinib. The effective separation was achieved through reversed-phased C18 column 4.6 x 250 mm, 5µm using a mobile phase Methanol: phosphate buffer (ph. 3.00) with orthophosphoric acid (OPA) (55:45 % v/v). The flow rate of the mobile phase was found to be 0.8 mL/min. The detection was carried at a wavelength of 244 nm. The retention time of Cabozantinib was found to be 3.702 min. The correlation coefficient was found to be 0.9999. The developed method was accurately validated in the terms of accuracy, linearity range, precision, system suitability, robustness, limit of detection and limit of quantification. The details presented in this test will be useful for industrial application for determining Cabozantinib in active pharmaceutical ingredient and pharmaceutical dosage form.


2019 ◽  
Vol 31 (5) ◽  
pp. 1002-1008
Author(s):  
Somana Siva Prasad ◽  
G.V. Krishna Mohan ◽  
A. Naga Babu

A novel reversed-phase high performance liquid chromatographic (HPLC) technique for the determination of everolimus (Isomer-B) and its impurities in the tablet dosage form has been optimized using analytical quality by design (QbD) approach. All the compounds are monitored with the photodiode array (PDA) detector at 280 nm and the parameters namely; precision, accuracy, specificity, stability, linearity, limit of quantitation (LOQ) and limit of detection (LOD) are evaluated. The quantitation limits of IMP-A, IMP-B, IMP-C, IMP-D, IMP-E, Sirolimus and TGR are found to be 0.08, 0.08, 0.10, 0.10, 0.10, 0.08 and 0.08, respectively. Recovery studies from 0.9 mg/L to 9.0 mg/L are performed for all impurities and the values were obtained between 85-110 %. Injection volume and test concentrations have been optimized to achieve LOQ values under the reporting threshold. The whole technique is developed and validated as per International Council for Harmonization (ICH) guidelines. The proposed method is robust, sensitive, rapid and successful and helpful in the regions where regulatory agencies recommend HPLC analytical method.


Author(s):  
Bhupender Tomar ◽  
Ankita Sharma ◽  
Inder Kumar ◽  
Sandeep Jain ◽  
Pallavi Ahirrao

A simple, precise, and accurate reverse phase high performance liquid chromatographic method (RP-HPLC) was developed and validated for the estimation of the combination of 5- Fluorouracil (5-FU) and Imiquimod in active pharmaceutical ingredients (APIs). The method was carried out on Phenomenex C18 (250 × 4.6mm I.D., 5𝜇m) using isocratic elution mode. The mobile phase was used as Acetonitrile: 10mM potassium dihydrogen orthophosphate: triethylamine (40:59.9:0.1, v/v, pH 4.5 with orthophosphoric acid) and Water: ACN (50:50 v/v) was used as a diluent. The concentration of solvents was 1-20µg/ml and the volume of injection was 20µl with the flow rate of 1.2ml/min. The retention times for 5-FU and Imiquimod were found to be 1.9±0.5 and 6.6±0.5 min respectively. The absorption maxima of 5FU and Imiquimod were found 267nm and 227nm respectively. The method was validated as per ICH guidelines. All the data were found within the specified limits. The limit of detection (LOD) and limit of quantification (LOQ) of 5- Fluorouracil were found to be 0.015μg/mL and 0.048 μg/mL, respectively, and Imiquimod was found to be 0.078μg/mL and 0.237μg/mL, respectively. The method developed in the present study was found to be sensitive, specific, and precise and can be applied for the simultaneous estimation of 5-FU and Imiquimod.


INDIAN DRUGS ◽  
2013 ◽  
Vol 50 (05) ◽  
pp. 48-52
Author(s):  
A Lodhi ◽  
◽  
A Jain ◽  
B. Biswal

A validated high performance liquid chromatographic method was developed for the determination of chromium picolinate in pharmaceutical dosage forms. The analysis was performed at room temperature using a reversed-phase ODS, 5µm (250×4.6) mm column. The mobile phase consisted of acetonitrile: buffer (60:40 V/V) at a flow rate of 0.5 mL/min. The PDA-detector was set at 264 nm. The developed method showed a good linear relationship in the concentration range from 1.5 – 12.5 µg/mL with a correlation coefficient from 0.999. The limit of detection and limit of quantification were 0.0540513 and 0.1637919 µg/mL respectively.


2012 ◽  
Vol 1 (12) ◽  
pp. 410-413 ◽  
Author(s):  
Sukhbir Lal Khokra ◽  
Balram Choudhary ◽  
Heena Mehta

A rapid, simple and highly sensitive reversed phase high performance liquid chromatographic (RP-HPLC) method has been developed for the quantitative determination of Rabeprazole sodium and Aceclofenac in a combined dosage form. Rabeprazole sodium and Aceclofenac were chromatographed using C-18 column as stationary phase and methanol: acetonitrile: water (60 : 10 : 30 v/v/v) as the mobile phase at a flow rate of 1.0 ml/min at ambient temperature and detected at 280 nm. The retention time (RT) of Rabeprazole sodium and Aceclofenac were found to be 5.611 min and 2.102 minute, respectively. The linearities of Rabeprazole sodium and Aceclofenac were in the range of 1-10 µg/ml and 3-15 µg/ml, respectively. The limit of detection was found to be 0.091 µg/ml for Rabeprazole sodium and 0.043 µg/ml for Aceclofenac. The proposed method was applied for the determination of Rabeprazole sodium and Aceclofenac in a combined dosage form and result was found satisfactory.DOI: http://dx.doi.org/10.3329/icpj.v1i12.12450 International Current Pharmaceutical Journal 2012, 1(12): 410-413


Author(s):  
Ch. Jaswanth Kumar ◽  
Prachet Pinnamaneni ◽  
Siva Prasad Morla ◽  
K. N. Rajini Kanth ◽  
Rama Rao Nadendla

Aims: The main aim of the present study was to develop and validate a simple and cost- effective method for the estimation of allopurinol and its related substances by using RP-HPLC. Study Design:  Estimation of Allopurinol and its related substance in bulk and tablet dosage forms by RP-HPLC. Place and Duration of Study: Chalapathi Drug Testing Laboratory, Chalapathi Institute of Pharmaceutical Sciences, Chalapathi Nagar, Lam, Guntur-522034 between October 2020 to January 2021. Methodology: Method development was carried out by using Schimadzu, Prominence-i series LC 3D-Plus autosampler embedded with lab solutions software, equipped with PDA detector using YMC column (150 mm X 4.6 mm, 3 μm) and 0.1M Ammonium acetate buffer as a mobile phase in the ratio of 100% at a flow rate of 1.0 ml/min at a wavelength of 255nm. The developed method was validated according to ICH guidelines. Results:  The linearity was observed in the range of 20-100 µg/ml with a regression (R2) value of 0.999. Developed method was specific with no interactions and accurate with 100.11% for allopurinol and 99.54% for its related substance. The limit of detection for allopurinol was 2 µg/ml and for related substance was 0.0.1 µg/ml. The limit of quantification for allopurinol was 6 µg/ml and for related substance was 0.03 µg/ml respectively. The percentage relative standard deviation was found to be NMT 2 which indicates that the proposed method was precise and robust. Conclusion:  The developed method was simple, precise and accurate and can be successfully employed for the estimation of allopurinol in bulk and tablet dosage form.


Sign in / Sign up

Export Citation Format

Share Document