scholarly journals Diagnostic Accuracy of Doppler Ultrasound Compared to Surgical Exploration in Torsion Testis

2021 ◽  
Vol 10 (35) ◽  
pp. 3035-3039
Author(s):  
Murali Thekeveetil ◽  
Sajitha Krishnadas ◽  
, JayaKoothupalakal Vishwambharan

BACKGROUND Twisting of the spermatic cord resulting in ischemia of the testicles known as testicular torsion is a surgical emergency. Delay in diagnosis or surgery results in loss of testicles. Doppler ultrasound of scrotum is used in evaluating acute scrotum to support or rule out a diagnosis of torsion testis. Our study compares Doppler results with findings at exploration to finding out the accuracy of Doppler diagnosis in this scenario. METHODS This was a record based observational cross-sectional study. Out of all cases of acute scrotum presented to a tertiary care hospital over 14 months time, those patients with Doppler evaluation done were identified (n = 52) and their surgical findings were compared to the Doppler findings. Diagnostic accuracy of Doppler in diagnosing torsion testis was measured using sensitivity, specificity, accuracy, and predictive values. RESULTS Out of these 52 cases, 44 (84.6 %) were testicular torsion on exploration while remaining cases were epididymo-orchitis four (7.7 %) and testicular appendage torsion four (7.7 %). Among 44 cases of torsion testis, 31 (70.5 %) patients underwent orchiectomy (70.45 %) and in remaining 13 (29.5 %) orchiopexy was done. Sensitivity of Doppler to diagnose testicular torsion was 86.4 %, specificity was 87.5 % and accuracy was 86.54 %. Positive predictive value (PPV) was 97.4 % and negative predictive value (NPV) was 53.8 %. CONCLUSIONS Doppler ultrasound can be used as an adjunct to clinical findings in acute scrotum. High positive predictive value suggest that all Doppler diagnosed torsion should undergo emergency exploration as it will be correct in 97.5 % cases. If performing a Doppler study delays the definitive management, and if clinical findings are highly suggestive of testicular torsion, treating doctor can proceed to surgery without Doppler evaluation. KEY WORDS Doppler, Torsion Testis, Scrotum

2011 ◽  
Vol 152 (23) ◽  
pp. 909-912 ◽  
Author(s):  
Laura Sándor ◽  
Tímea Gajda ◽  
Vanda Aranyi ◽  
István Csízy ◽  
Tamás Cserni

Acute scrotum, when testicular torsion is suspected, needs emergency exploration. However, acute scrotum caused by torsion of the Morgagni hydatid and epididymitis can be managed conservatively. Real time colour Doppler ultrasound is becoming a more and more popular tool in the differential diagnosis, however, its reliability is still not widely accepted and exploration is preferred. Material and methods: Case notes of 124 patients treated with acute scrotum during the last 10 years have been reviewed, and the result of physical examination, color Doppler ultrasound, operative notes and clinical outcome were analysed. Results: The final diagnosis was torsion of Morgagni hydatid in 100 cases, furthermore 11 testicular torsion, 8 epididymitis and 10 idiopathic cases were identified. Preoperative colour Doppler ultrasound was done in 45 cases, and exploration was performed in 111 cases. In 38 cases the colour Doppler ultrasound excluded and in 7 cases verified the possibility of testicular torsion. Two false positive and 0 false negative cases were identified. The specificity was 95.0%, sensitivity 100.0%, negative predictive value 100.0%, and positive predictive value 71.4%. Discussion: Colour Doppler ultrasound seems to be a reliable tool in the differential diagnosis of acute scrotum. Its routine use could reduce the number of emergency explorations. Orv. Hetil., 2011, 152, 909–912.


2018 ◽  
Vol 23 (3) ◽  
pp. 100-103
Author(s):  
Ajak Makor ◽  
Josephat Jombwe ◽  
Moses Galukande ◽  
Alex E. Elobu

Background: The management of acute appendicitis remains challenging with high peri-operative morbidity and mortality due diagnostic delay or high negative appendicetomy rates due to aggressive surgical approaches. CT scan is accurate for pre-operative diagnosis but not available or affordable in all settings. There remains a need for an affordable yet accurate tool for diagnosing acute appendicitis in the resource limited setting. Methods: To determine the diagnostic accuracy of Tzanakis score in the preoperative evaluation of patients with acute appendicitis, we conducted a descriptive cross-sectional study at Mulago Hospital in Kampala, Uganda. Eligible consenting patients diagnosed with acute appendicitis consecutively underwent Tzanakis scoring and appendicectomy. Appencieal samples were sent for histological examination. Sensitivity, specificity, positive predictive value, negative predictive values, and diagnostic accuracy of the Tzanakis scoring system were calculated, relative to histological examination. Results: We enrolled 160 participants of mean age 30.4 years with male:female ratio of 2:1. The Tzanakis score had sensitivity of100% (95% CI 98-100), positive predictive value 97 % (95% CI 95-99), specificity of 64% (95% CI 31-89), negative predictive value of 100%, and overall diagnostic accuracy of 98% with 3% negative appendectomy rate. Conclusions: The Tzanakis score is found to be a sensitive and specific tool that should be considered for preoperative diagnosis of acute appendicitis in resource limited settings. Keywords: appendicitis; appendicectomy; acute abdomen; diagnosis; Tzanakis score; Uganda 


2018 ◽  
Vol 5 (3) ◽  
pp. 796
Author(s):  
Vamsavardhan Pasumarthi ◽  
C. P. Madhu

Background: The RIPASA Score is a new diagnostic scoring system developed for the diagnosis of Acute Appendicitis which showed higher sensitivity, specificity and diagnostic accuracy compared to ALVARADO Score, particularly when applied to Asian population. Not many studies have been conducted to compare RIPASA and ALVARADO scoring systems. Hence, author want to compare prospectively Alvarado and RIPASA score by applying them to the patients attending the hospital with right iliac fossa pain that could probably be acute appendicitis.Methods: A prospective analysis of 116 cases admitted with RIF pain during a 2 years period was performed. Patients between 15-60 years were scored as per Alvarado and RIPASA scoring system. Histopathological reports of the cases were collected and compared with the scores. ROC curve area analysis was performed to examine diagnostic accuracy of RIPASA and ALVARADO scores.Results: The sensitivity of ALVARADO score is estimated to be 52.08 for a cut off of 6. The specificity is 80%, positive predictive value is 92.59, negative predictive value is 25.81. The Diagnostic accuracy of ALVARADO scoring is found to be 56.9. The sensitivity, specificity, positive predictive value and negative predictive values of RIPASA scoring system are 75%, 65%, 91.14%, 35.14%. The diagnostic accuracy of RIPASA score is 73.28.Conclusions: The difference in the diagnostic accuracy between ALVARADO and RIPASA scoring system is significant indicating that the RIPASA score is a much better diagnostic tool for the diagnosis of acute appendicitis. When the ROC curve was observed the area under the curve is high for RIPASA scoring system.


2020 ◽  
Vol 14 (2) ◽  
pp. 97-102
Author(s):  
Khalid Rehman `Yousaf ◽  
Shahzad Saeed ◽  
Saman Chaudhry ◽  
Rabia Bashrat ◽  
Abadullah Khalid ◽  
...  

Background: Ovarian torsion diagnosis is a great challenge as delay in diagnosis can cause severe morbidity. Early accurate diagnosis is crucial to preserve ovarian function. Ultrasonography being the primary imaging modality plays a vital role in the evaluation of suspected ovarian torsion by helping surgeons reach the correct diagnosis, thus avoiding unnecessary intervention. This study aims to determine the diagnostic accuracy of isolated and combined sonographic features of ovarian torsion on grey scale and Doppler transvaginal ultrasonography. Patients and methods: From radiology database, from January 2016 till December 2019, sonographic signs of ovarian torsion in 113 women with suspected ovarian torsion on ultrasonography and subsequent surgical diagnosis were evaluated. Ultrasound findings were compared with surgical findings to determine the accuracy, sensitivity, specificity, and positive and negative predictive values of individual and combined ultrasound signs. Results: Diagnostic accuracy of ultrasound for ovarian torsion was 85.8%. Abnormal ovarian Doppler flow was the most accurate individual sonographic sign with accuracy, sensitivity, specificity and positive predictive value of 85.8%, 83.5%, 100% and 100% respectively followed by ovarian enlargement and ovarian edema. Combined ultrasound signs resulted in higher sensitivity and positive predictive values, and lower specificity and negative predictive values for ovarian torsion. Increasing the number of sonographic parameters increased the specificity but decreased sensitivity. High accuracy, sensitivity, positive predictive value, specificity and negative predictive value was seen when combination of three or two sonographic parameters was used as diagnostic criteria. Conclusion: Transvaginal sonography is a convenient, reliable and extremely useful imaging modality for preoperative diagnosis of ovarian torsion with high specificity, sensitivity, positive predictive value and diagnostic accuracy helping treating physicians to take prompt decisions regarding timely surgical intervention. However, due to low negative predictive values, absence of sonographic signs does not rule out ovarian torsion and high index of clinical suspicion remains of utmost importance.


2021 ◽  
pp. 22-24
Author(s):  
Monica Sarohi ◽  
Kavita Mardi

Introduction- Milan system is an evidence based system derived from the literature which correlates diagnostic categories with risk of malignancy and clinical management strategies. The goals of this system were to standardize salivary gland cytology reporting across institutions and provide a framework for guiding clinical management. It is a tier based classication having six diagnostic categories. The conventional system was used for diagnosis before the advent of Milan system. In this study, FNAC done for all sa Material and methods- livary gland lesions over a period of two years from 2018 - 2020 in department of pathology, IGMC Shimla are included. All cases are categorized according to MSRSGC and correlated with histopathological follow up wherever available. We calculated the sensitivity, specicity, positive predictive value, negative predictive value and diagnostic accuracy of FNA using the Milan system. We also calculated the ROM was for each category. All the cases were Results: categorized as per MSRSGC and were 14%, 45.4%, 0%, 31.4%, 0.6%, 0.6% and 8% in category I, II, III, IVA, IVB, V and VI respectively. ROM for category I, II, IVA, IVB, V and VI was 0%, 0%, 2.6%, 0%, 100% and 87.5% respectively. The sensitivity, specicity, positive predictive value, negative predictive value and diagnostic accuracy was 98.51%, 66.67%, 98.51%, 66.67% and 97.14% respectively. Milan system is an Discussion: effective tool for diagnosing salivary gland lesions. It offers advantages over the conventional system such as risk of malignancy, management options for each category and a better communication both institute wise and between clinicians and cytopathologists.


2017 ◽  
Vol 4 (8) ◽  
pp. 2556 ◽  
Author(s):  
Yashwant R. Lamture ◽  
Harshal Ramteke ◽  
R. K. Shinde ◽  
Vinay V. Shahapurkar ◽  
Varsha P. Gajbhiye

Background: Of the many scoring systems currently available, the modified Alvarado scoring system (MASS) is the most widely employed, because of its ability to reduce negative appendectomy rate (NAR). Unfortunately, this system is more accurate in western population. In spite of the advances in the diagnostic and imaging techniques NAR have not decreased much. This clearly indicates the need of development of new diagnostic scoring system so we have developed new diagnostic scoring system (Yash Score). The objective of this study was to develop and study diagnostic accuracy of new diagnostic scoring system (Yash scoring system) for acute appendicitis.Methods: A prospective comparison YSS and MASS was done on 418 patients. Depending on clinical judgement appendicectomy was done. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy for YSS and MASS were calculated using SPSS 17.0 statistical software for statistical analysis and compared using Chi-square test.Results: The sensitivity and specificity of YSS was found to be 99.48 per cent and 92.86 percent respectively. The sensitivity and specify of MASS was 52.05 per cent and 100 per cent respectively. The positive predictive value and negative predictive value of YSS was 99.48 per cent and 92.86 per cent respectively. Negative and positive predictive values of MASS were 13.02% and 100% respectively.Conclusions: Comparison in between YSS and MASS in the present study shows significant statistical difference.


Author(s):  
Luke Burnett ◽  
Chunyang Wang ◽  
Feng Zhang ◽  
Stephan Adams ◽  
Joan Wilson ◽  
...  

Abstract Background Toxic epidermal necrolysis (TEN) is a severe, life-threatening mucocutaneous reaction, causing widespread sloughing of skin and mucosal surfaces. Accurate and prompt diagnosis is essential for optimal management and subsequent outcome. In this study, frozen sections were used as a rapid examination for initial diagnosis of TEN, and the frozen section diagnoses were assessed compared with permanent sections. Methods One hundred patients of suspected TEN were referred to our burn unit, and 67 had sufficient clinical findings for frozen and permanent biopsies. The accuracy of frozen section relative to permanent section was evaluated by calculating diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). And McNemar’s tests were used to analyze the difference between the two methods. Results Fifty-two specimens were classified as TEN by frozen section, 51 of which were confirmed by permanent biopsy. The exception was diagnosed as bullous pemphigoid on permanent section. Fifteen specimens were read as negative for TEN on frozen slides but 4 were changed to positive by permanent biopsy. Overall, the diagnostic accuracy of frozen section was 92.5%, with sensitivity and specificity 92.7% and 91.7% respectively. The positive predictive value, or coherence of positive diagnosis between the two methods, was as high as 98.1%, and the negative predictive value was 73.3%. The p-value of McNemar’s tests was 0.375, indicating there was no significant difference between the two biopsy methods. Conclusion The data suggest that as a rapid histological assessment, frozen section is a reliable tool in the early diagnosis of TEN.


2021 ◽  
pp. 019459982110137
Author(s):  
Derek Kai Kong ◽  
Amanda M. Kong ◽  
Raymond L. Chai

Objective To measure the effect of thyroidectomy difficulty on intraoperative neuromonitoring false loss of signal (LOS) and to compare intraoperative endotracheal tube–based neuromonitoring (ETNM) and Checkpoint palpation-based direct stimulation (pDS) signals with postoperative laryngoscopy. We hypothesized that pDS has higher a positive predictive value for postdissection confirmation of recurrent laryngeal nerve function than ETNM and that this difference is accentuated with increasing thyroidectomy difficulty. Study Design Prospective single-arm cross-sectional study comparing ETNM and pDS for patients undergoing hemi-, total, or completion thyroidectomy from July 2018 to March 2020. Setting Single-surgeon series at a tertiary care hospital. Methods Percentage concordance and positive and negative predictive values were measured. Each thyroidectomy was assigned a validated thyroidectomy difficulty score, and recorded recurrent laryngeal nerve signals were compared with postoperative vocal fold mobility. Results Percentage concordance was 90.09%. Positive and negative predictive values were 0.19 (95% CI, 0.09-0.31) and 1.0 for ETNM and 0.59 (95% CI, 0.35-0.82) and 1.0 for pDS. The difference in positive predictive value was significant (0.40 [95% CI, 0.33-0.47], P < .001). False LOS rates for ETNM and pDS were 13.19% versus 3.30% (9.89% [95% CI, 1.80%-18.62%], P = .0155), 44.11% versus 0% (44.11% [95% CI, 25.80%-60.54%], P < .001), and 73.33% versus 13.33% (60% [95% CI, 24.76%-78.46%], P = .001) for the second through fourth thyroidectomy difficulty score quartiles, respectively. False LOS with ETNM was linearly correlated with increasing difficulty ( R2 = 0.97). Conclusion ETNM was subject to high rates of postdissection false LOS that increased with thyroidectomy difficulty score. pDS is a reliable alternative that has higher positive predictive value than ETNM, particularly in more challenging cases such as those with posteriorly fixed thyroid cancers and fibrotic glands. Evidence level 2.


2010 ◽  
Vol 4 ◽  
pp. CMC.S3864 ◽  
Author(s):  
M. Wehrschuetz ◽  
E. Wehrschuetz ◽  
H. Schuchlenz ◽  
G. Schaffler

Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subsequent introduction of 64-slice scanners promised excellent and fast results for coronary artery studies. This prompted us to evaluate the diagnostic accuracy, sensitivity, specificity, and the negative und positive predictive value of 64-slice MSCT in the detection of haemodynamically significant coronary artery stenoses. Thirty-seven consecutive subjects with suspected coronary artery disease were evaluated with MSCT angiography and the results compared with QCA. All vessels were considered for the assessment of significant coronary artery stenosis (diameter reduction ≥ 50%). Thirteen patients (35%) were identified as having significant coronary artery stenoses on QCA with 6.3% (35/555) affected segments. None of the coronary segments were excluded from analysis. Overall sensitivity for classifying stenoses of 64-slice MSCT was 69%, specificity was 92%, positive predictive value was 38% and negative predictive value was 98%. The interobserver variability for detection of significant lesions had a κ-value of 0.43. Sixty-four-slice MSCT offers the diagnostic potential to detect coronary artery disease, to quantify haemodynamically significant coronary artery stenoses and to avoid unnecessary invasive coronary artery examinations.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
M Moshage ◽  
S Smolka ◽  
S Achenbach ◽  
F Ammon ◽  
P Ferstl ◽  
...  

Abstract Background The accuracy of CT-derived FFR (FFRCT) has been repeatedly reported. However, the influence of lesion location on accuracy is unknown. Therefore, we evaluated the diagnostic accuracy of FFRCT to detect lesion-specific ischemia and determined the influence of lesion location (proximal vs. distal vessel segments) compared to invasively measured FFR in patients with suspected CAD. Methods A total of 136 vessels in which “Dual-Source”-CT coronary angiography had been performed due to suspected CAD and who were further referred for invasive coronary angiography with invasive FFR measurement within three months of the index CT examination were retrospectively identified and screened for inclusion in this analysis. Patients with either left main coronary artery stenoses, bifurcation or ostial stenoses were excluded. Invasive FFR was measured using a pressure wire (CERTUS®, St. Jude Medical, Minnesota, USA or Verrata®, Volcano, San Diego, USA). FFRCT was calculated using an on-site prototype (cFFR Version 3.0, Siemens Healthineers, Forchheim, Germany). All vessels were analyzed by an experienced observer blinded to the results of invasive FFR. Stenoses with invasively measured FFR ≤0.80 were classified as hemodynamically significant. We evaluated the diagnostic accuracy of FFRCT in proximal vs. non-proximal vessel segments. Proximal lesions included stenoses located in segment one, six, eleven and twelve. All other stenoses were categorized as distal lesions. Results Out of 136 coronary stenoses, 47 (35%) were located in proximal segments and 89 (65%) lesions were located in distal segments. Compared to invasive FFR, the sensitivity of FFRCT to correctly identify/exclude hemodynamically significant stenoses in proximal vessel segments was 93% (95% CI: 68–99.8%) and the specificity was 100% (95% CI: 89–100%), compared to a sensitivity of 72% (95% CI: 46.5–90%) and a specificity of 87% (95% CI: 77–94%) for FFRCT in distal lesions. The positive predictive value was 100% and the negative predictive value was 97% (95% CI: 82.8–99.5%) compared to a positive predictive value of 59% (95% CI: 42–93.9%) and a negative predictive value of 93% (95% CI: 85.4–96.3%) for proximal vs. distal vessel segment, respectively. This corresponds to an accuracy of 98% vs. 84%, respectively (p=0.02). ROC-Curve analysis showed a slightly higher – albeit non-significant – area under the curve for FFRCT to detect hemodynamic relevance in proximal lesions compared to distal lesions (AUC 0.95, p&lt;0.001 vs. AUC: 0.86, p&lt;0.001, respectively, p=0.2). Conclusion FFRCT obtained using an on-site prototype shows overall a high diagnostic accuracy for detecting lesions causing ischemia as compared to invasive FFR with a trend towards better diagnostic performance in proximal vessel segments. Funding Acknowledgement Type of funding source: None


Sign in / Sign up

Export Citation Format

Share Document