scholarly journals FIRE PERFORMANCE OF COMPOSITE-PANEL SEPARATION WALLS

Author(s):  
Miroslav Smolka ◽  
Vladimír Mózer ◽  
Piotr Tofiło

Composite panel walls with both combustible and non-combustible cores were subjected to fire resistance test to EN 1364-1. The results revealed that the combustible-core panels started emitting smoke on the unexposed side due to the presence of joints between panels. In some cases the smoke emission started early after the start for the fire exposure. The start of the smoke production period appeared to depend on the fixation of the panels to the furnace frame; three or four sides fixed as per EN 1364-1. The amounts of smoke released indicate that although smoke leakage/production criterion is not currently part of the standard fire-resistance testing protocol it should be assessed when construction elements with combustible components are tested. Otherwise such a barrier may not be considered as a smoke-safe separating element, because model FED calculations indicate a potential threat to the occupants on the unexposed side at a certain set of conditions.

2021 ◽  
Vol 11 (6) ◽  
pp. 2521
Author(s):  
Feng Jiang ◽  
Jianyong Liu ◽  
Wei Yuan ◽  
Jianbo Yan ◽  
Lin Wang ◽  
...  

Improving the fire resistance of the key cables connected to firefighting and safety equipment is of great importance. Based on the engineering practice of an oil storage company, this study proposes a modification scheme that entails spraying fire-retardant coatings on the outer surface of a cable tray to delay the failure times of the cables in the tray. To verify the effect, 12 specimens were processed using five kinds of fire-retardant coatings and two kinds of fire-resistant cotton to coat the cable tray. The specimens were installed in the vertical fire resistance test furnace. For the ISO 834 standard fire condition, a fire resistance test was carried out on the specimens. The data for the surface temperature and the insulation resistance of the cables in trays were collected, and the fireproof effect was analyzed. The results showed that compared with the control group, the failure time of the cable could be delayed by 1.57–14.86 times, and the thicker the fire-retardant coatings were, the better the fireproof effect was. In general, the fire protection effect of the fire-retardant coating was better than that of the fire-resistant cotton.


Author(s):  
Kyung Soo Chung ◽  
Jae Sung Lee ◽  
Jong Eun Song ◽  
Woo Chul Kim ◽  
Heung Youl Kim ◽  
...  

New concrete filled double-tube (CFDT) sections consist of an inner and outer tube with fire protection mortar (FPM) filling the cavity between them and the inner tube also filled with concrete or not. An investigation into the fire performance of CFDT during the standard fire test is reported. Six full size FPM filled CFDT columns were designed for the fire tests. Detail failure modes of overall specimens and each component in the columns as well as temperature, deformation and fire endurance were presented. It showed that the fire resistance in the CFDT columns is significantly higher than that in concrete filled steel tubular (CFT) columns. Investigation into the fire performance of the columns reveals possible solutions to improve the fire resistance of CFT members.


Author(s):  
Paweł Sulik ◽  
Jacek Kinowski ◽  
Bartłomiej Sędłak

This paper discusses the main issues related to the fire resistance of aluminium glazed curtain walls including the tests methodology and way of classification of this type of building elements. Moreover, the paper presents the comparison of fire resistance test results of large test specimens of curtain walls in full configuration depending on the side of fire exposure. Temperature rises have been compared on unexposed surface of the curtain walls tested for standard and external fire exposure. To made the comparison four test specimens of glazed aluminium curtain walls in full configuration, were tested. Curtain walls had the same transom – mullion structure. Two test specimens were tested for external fire exposure, and two for standard fire exposure. Dimensions of exposed surfaces were 5000 x 4500 mm (width x height) for external fire exposure and 5000 x 4800 mm (width x height) for internal fire exposure.


2012 ◽  
Vol 193-194 ◽  
pp. 539-543
Author(s):  
Zhao Peng Ni ◽  
Pei Fang Qiu

Abstract : A series of standard fire-resistance tests were carried out to study the fire performance, failure modes and fire-resistance ratings of glulam beams. The test results showed that these glulam beams performed well during the tests, and the fire-resistance rating requirements can be achieved as expected. The study has provided necessary knowledge and experimental data for the determination of fire-resistance performance of glulam beams in the fire code of China.


1996 ◽  
Vol 27 (2) ◽  
pp. 91-112 ◽  
Author(s):  
G. Thomson ◽  
R.R. Preston

2009 ◽  
Vol 6 (7) ◽  
pp. 102275 ◽  
Author(s):  
V. K. R. Kodur ◽  
R. Fike ◽  
Art Parker ◽  
S. W. Dean