scholarly journals The Way of Reducing Current Values in Optical Ground Wires at Asymmetrical Faults on Overhead Transmission Lines

2016 ◽  
Vol 11 (1) ◽  
pp. 13-20
Author(s):  
Georgiy Egamnazarov

Abstract Given the fact that the installing costs of an optical ground wire on overhead lines directly depend on its cross-section, which in turn depends on the level of fault current it should withstand, in order to reduce these current values in the optical ground wire, I suggested performing its isolated descents from the end towers of the line with its transition to an optical cable. The research was carried out on the example of a 500 kV overhead line in the National Electric Power Grid. The Method of Symmetrical Components for calculating asymmetrical fault currents was not used; therefore, calculations were carried out on the base of presenting the line as a multi-wire system for the considered case as a five-wire system (optical ground wire, steel ground wire, and three phase wires). Such approach allows taking into account the initial asymmetry of the line parameters and modeling any kind of asymmetrical faults. The analyses of calculated results were performed. The conclusive evidence that the optical ground wire isolated descents from the end towers of the line give the possibility of reducing the level of maximal fault current distribution values in it and therefore its cross section, is presented.

2019 ◽  
Vol 9 (9) ◽  
pp. 1737 ◽  
Author(s):  
Bin Jiang ◽  
Yanfeng Gong

A modular multilevel converter based high-voltage DC (MMC-HVDC) system has been the most promising topology for HVDC. A reclosing scheme is usually configured because temporary faults often occur on transmission lines especially when overhead lines are used, which often brings about an overcurrent problem. In this paper, a new fault current limiter (FCL) based on reclosing current limiting resistance (RCLR) is proposed to solve the overcurrent problem during the reclosing process. Firstly, a mesh current method (MCM) based short-circuit current calculation method is newly proposed to solve the fault current calculation of a loop MMC-HVDC grid. Then the method to calculate the RCLR is proposed based on the arm current to limit the arm currents to a specified value during the reclosing process. Finally, a three-terminal loop MMC-HVDC test grid is constructed in the widely used electromagnetic transient simulation software PSCAD/EMTDC and the simulations prove the effectiveness of the proposed strategy.


2014 ◽  
Vol 134 (11) ◽  
pp. 939-947 ◽  
Author(s):  
Keiichiro Hirokado ◽  
Naoki Yamamura ◽  
Muneaki Ishida

Author(s):  
Svetlana Guseva ◽  
Lubov Petrichenko

The choice of optimum cross section for overhead line by economic intervals' methodIn this paper an approach to choosing the optimum cross section for overhead line in conditions of incomplete and uncertain information is considered. The two methods of such choice are presented: method of economic current density and economic intervals' method. The correction of the economic intervals method is offered under market conditions of costs. As example 20 kV and 110 kV overhead lines with aluminum, copper and ferroaluminum wires are selected. Universal nomograms with different standard cross section are calculated and constructed. The graphics using Mathcad software are offered.


Author(s):  
Hans Peter Kraemer ◽  
Anne Bauer ◽  
Michael Frank ◽  
Peter Van Hasselt ◽  
Peter Kummeth ◽  
...  