scholarly journals Within-Session Stability of Short-Term Heart Rate Variability Measurement

2016 ◽  
Vol 50 (1) ◽  
pp. 85-92 ◽  
Author(s):  
Lukas Cipryan

AbstractThe primary aim of this study was to assess the retest stability of the short-term heart rate variability (HRV) measurement performed within one session and without the use of any intervention. Additionally, a precise investigation of the possible impact of intrinsic biological variation on HRV reliability was also performed. First, a single test-retest HRV measurement was conducted with 20-30 min apart from one another. Second, the HRV measurement was repeated in ten non-interrupted consecutive intervals. The lowest typical error (CV = 21.1%) was found for the square root of the mean squared differences of successive RR intervals (rMSSD) and the highest for the low frequency power (PLF) (CV = 93.9%). The standardized changes in the mean were trivial to small. The correlation analysis revealed the highest level for ln rMSSD (ICC = 0.87), while ln PLF represented the worst case (ICC = 0.59). The reliability indices for ln rMSSD in 10 consecutive intervals improved (CV = 9.9%; trivial standardized changes in the mean; ICC = 0.96). In conclusion, major differences were found in the reliability level between the HRV indices. The rMSSD demonstrated the highest reliability level. No substantial influence of intrinsic biological variation on the HRV reliability was observed.

2015 ◽  
Vol 24 (2) ◽  
pp. 118-127 ◽  
Author(s):  
Muna H. Hammash ◽  
Debra K. Moser ◽  
Susan K. Frazier ◽  
Terry A. Lennie ◽  
Melanie Hardin-Pierce

BackgroundWeaning from mechanical ventilation to spontaneous breathing is associated with changes in the hemodynamic and autonomic nervous systems that are reflected by heart rate variability. Although cardiac dysrhythmias are an important manifestation of hemodynamic alterations, the impact of heart rate variability on the occurrence of dysrhythmias during weaning has not been specifically studied.ObjectivesTo describe differences in heart rate variability spectral power and occurrence of cardiac dysrhythmias at baseline and during the initial trial of weaning from mechanical ventilation and to evaluate the impact of heart rate variability during weaning on occurrence of dysrhythmias.MethodContinuous 3-lead electrocardiographic recordings were collected from 35 patients receiving mechanical ventilation for 24 hours at baseline and during the initial weaning trial. Heart rate variability was evaluated by using spectral power analysis.ResultsLow-frequency power increased (P = .04) and high-frequency and very-low-frequency power did not change during weaning. The mean number of supraventricular ectopic beats per hour during weaning was higher than the mean at baseline (P < .001); the mean of ventricular ectopic beats did not change. Low-frequency power was a predictor of ventricular and supraventricular ectopic beats during weaning (P < .001). High-frequency power was predictive of ventricular and supraventricular (P = .02) ectopic beats during weaning. Very-low-frequency power was predictive of ventricular ectopic beats (P < .001) only.ConclusionHeart rate variability power spectra during weaning were predictive of dysrhythmias. (American Journal of Critical Care. 2015;24:118–127)


1997 ◽  
Vol 92 (2) ◽  
pp. 167-174 ◽  
Author(s):  
Gervais Tougas ◽  
Markad Kamath ◽  
Geena Watteel ◽  
Debbie Fitzpatrick ◽  
Ernest L. Fallen ◽  
...  

1. The heart and the oesophagus have similar sensory pathways, and sensations originating from the oesophagus are often difficult to differentiate from those of cardiac origin. We hypothesized that oesophageal sensory stimuli could alter neurocardiac function through autonomic reflexes elicited by these oesophageal stimuli. In the present study, we examined the neurocardiac response to oesophageal stimulation and the effects of electrical and mechanical oesophageal stimulation on the power spectrum of beat-to-beat heart rate variability in male volunteers. 2. In 14 healthy volunteers, beat-to-beat heart rate variability was compared at rest and during oesophageal stimulation, using either electrical (200 μs, 16 mA, 0.2 Hz) or mechanical (0.5 s, 14 ml, 0.2 Hz) stimuli. The power spectrum of beat-to-beat heart rate variability was obtained and its low- and high-frequency components were determined. 3. Distal oesophageal stimulation decreased heart rate slightly (both electrical and mechanical) (P < 0.005), and markedly altered heart rate variability (P < 0.001). Both electrical and mechanical oesophageal stimulation increased the absolute and normalized area of the high-frequency band within the power spectrum (P < 0.001), while simultaneously decreasing the low-frequency power (P < 0.005). 4. In humans, oesophageal stimulation, whether electrical or mechanical, appears to amplify respiratory-driven cardiac vagoafferent modulation while decreasing sympathetic modulation. The technique provides access to vagoafferent fibres and thus may yield useful information on the autonomic effects of visceral or oesophageal sensory stimulation.


2021 ◽  
pp. 69-70
Author(s):  
Pakanati Sujana ◽  
Venkata Mahesh Gandhavalla ◽  
K. Prabhakara Rao

Introduction: COVID19 is caused by SARS-CoV-2 which is primarily transmitted through respiratory droplets and contact routes. WHO recommended the use of personal protective equipment (PPE) for prevention and N95 respirators are critical components of PPE. Breathing through N95 respirator will impart stress in the individual and that can be assessed by heart rate variability (HRV). HRV measures the variation in time between each heartbeat controlled by autonomic nervous system (ANS), which is a non invasive reliable index to identify the ANS imbalances. Aims And Objectives: This study is aimed at assessing the HRV of Interns working in COVID19 wards using N95 respirators. Methodology: This study included 100 interns in whom short term HRV was recorded using the standard protocol. Lead II of ECG was recorded using AD instruments (ADI) 8channel polygraph and HRV was analysed using Labchart 8pro software. The recordings were taken before and 1hour after wearing N95 respirator. Results: Overall HRV (SDRR) was found to decrease signicantly after wearing N95 respirator for 1hr (p=0.000). Similarly, indices representing the parasympathetic component ( RMSSD and HF ) were also found to decrease signicantly with the use of N95 respirator. Low frequency (LF) power and LF/HF ratio increased signicantly with N95 respirator use (p=0.000). Conclusion: We conclude that using N95 respirator increased sympathetic activity reecting decreased HRV in our subjects Hence we recommend that it is better to change the duty pattern for interns.


CHEST Journal ◽  
2011 ◽  
Vol 140 (4) ◽  
pp. 427A
Author(s):  
Subhasis Behera ◽  
Samuel Brown ◽  
Jason Jones ◽  
Michael Lanspa ◽  
Kathryn Kuttler ◽  
...  

2009 ◽  
Vol 76 (4 suppl 2) ◽  
pp. S51-S59 ◽  
Author(s):  
Jeffrey P. Moak ◽  
David S. Goldstein ◽  
Basil A. Eldadah ◽  
Ahmed Saleem ◽  
Courtney Holmes ◽  
...  

1996 ◽  
Vol 91 (4) ◽  
pp. 391-398 ◽  
Author(s):  
Piotr Ponikowski ◽  
Massimo Piepoli ◽  
Aham A. Amadi ◽  
Tuan Peng Chua ◽  
Derek Harrington ◽  
...  

1. In patients with chronic heart failure, heart rate variability is reduced with relative preservation of very-low-frequency power (< 0.04 Hz). Heart rate variability has been measured without acceptable information on its stability and the optimal recording periods for enhancing this reproducibility. 2. To this aim and to establish the optimal length of recording for the evaluation of the very-low-frequency power, we analysed 40, 20, 10 and 5 min ECG recordings obtained on two separate occasions in 16 patients with chronic heart failure. The repeatability coefficient and the variation coefficient were calculated for the heart rate variability parameters, in the time-domain (mean RR, SDRR and pNN50), and in the frequency-domain: very low frequency (< 0.04 Hz), low frequency (0.04–0.15 Hz), high frequency (0.15–0.40 Hz), total power (0–0.5 Hz). 3. Mean RR remained virtually identical over time (variation coefficient 8%). The reproducibility of time-domain (variation coefficient 25–139%) and of spectral measures (variation coefficient 45–111%) was very low. The stability of the heart rate variability parameters was only apparently improved after square root and after log transformation. 4. Very-low-frequency values derived from 5 and 10 min intervals were significantly lower than those calculated from 40 and 20 min intervals (P < 0.005). Discrete very-low-frequency peaks were detected in 11 out of 16 patients on the first 40, 20 and 10 min recording, but only in seven out of 16 when 5 min segments were analysed. 5. The reproducibility of both time or frequency-domain measures of heart rate variability in patients with chronic heart failure may vary significantly. Square root or log-transformed parameters may be considered rather than absolute units in studies assessing the influence of management on heart rate variability profile. Recordings of at least 20 min in stable, controlled conditions are to be recommended to optimize signal acquisition in patients with chronic heart failure, if very-low-frequency power in particular is to be studied.


1999 ◽  
Vol 276 (1) ◽  
pp. H215-H223 ◽  
Author(s):  
Melanie S. Houle ◽  
George E. Billman

The low-frequency component of the heart rate variability spectrum (0.06–0.10 Hz) is often used as an accurate reflection of sympathetic activity. Therefore, interventions that enhance cardiac sympathetic drive, e.g., exercise and myocardial ischemia, should elicit increases in the low-frequency power. Furthermore, because an enhanced sympathetic activation has been linked to an increased propensity for malignant arrhythmias, one might also predict a greater low-frequency power in animals that are susceptible to ventricular fibrillation than in resistant animals. To test these hypotheses, a 2-min coronary occlusion was made during the last minute of exercise in 71 dogs with healed myocardial infarctions: 43 had ventricular fibrillation (susceptible) and 28 did not experience arrhythmias (resistant). Exercise or ischemia alone provoked significant heart rate increases in both groups of animals, with the largest increase in the susceptible animals. These heart rate increases were attenuated by β-adrenergic receptor blockade. Despite the sympathetically mediated increases in heart rate, the low-frequency power decreased, rather than increased, in both groups, with the largest decrease again in the susceptible animals: 4.0 ± 0.2 (susceptible) vs. 4.1 ± 0.2 ln ms2 (resistant) in preexercise control and 2.2 ± 0.2 (susceptible) vs. 2.9 ± 0.2 ln ms2 (resistant) at highest exercise level. In a similar manner the parasympathetic antagonist atropine sulfate elicited significant reductions in the low-frequency power. Although sympathetic nerve activity was not directly recorded, these data suggest that the low-frequency component of the heart rate power spectrum probably results from an interaction of the sympathetic and parasympathetic nervous systems and, as such, does not accurately reflect changes in the sympathetic activity.


2015 ◽  
Vol 18 (2) ◽  
pp. 307-312 ◽  
Author(s):  
Sz. Bogucki ◽  
A. Noszczyk-Nowak

AbstractHeart rate variability (HRV) is a well established mortality risk factor in both healthy dogs and those with heart failure. While the standards for short-term HRV analysis have been developed in humans, only reference values for HRV parameters determined from 24-hour ECG have been proposed in dogs. The aim of this study was to develop the reference values for short-term HRV parameters in a group of 50 healthy dogs of various breeds (age 4.86 ± 2.74 years, body weight 12.2 ± 3.88 kg). The ECG was recorded continuously for at least 180 min in a dark and quiet room. All electrocardiograms were inspected automatically and manually to eliminate atrial or ventricular premature complexes. Signals were transformed into a spectrum using the fast Fourier transform. The HRV parameters were measured at fixed times from 60-min ECG segments. The following time-domain parameters (ms) were analyzed: mean NN, SDNN, SDANN, SDNN index, rMSSD and pNN50. Moreover, frequency-domain parameters (Hz) were determined, including very low frequency (VLF), low frequency (LF) and high frequency (HF) components, total power (TP) and the LF/HF ratio. The results (means ± SD) were as follows: mean NN = 677.68 ± 126.89; SDNN = 208.86 ± 77.1; SDANN = 70.75 ± 30.9; SDNN index = 190.75 ± 76.12; rMSSD = 259 ± 120.17, pNN50 = 71.84 ± 13.96; VLF = 984.96 ± 327.7; LF = 1501.24 ± 736.32; HF = 5845.45 ± 2914.20; TP = 11065.31 ± 3866.87; LF/HF = 0.28 ± 0.11.


Sign in / Sign up

Export Citation Format

Share Document