Determination of Body Composition in African-American Children: Validation of Bioelectrical Impedence with Dual Energy X-ray Absorptiometry

Author(s):  
V.D. Lewy ◽  
K. Danadian ◽  
S. Arslanian
1993 ◽  
Vol 57 (3) ◽  
pp. 323-326 ◽  
Author(s):  
A G Johansson ◽  
A Forslund ◽  
A Sjödin ◽  
H Mallmin ◽  
L Hambraeus ◽  
...  
Keyword(s):  

2006 ◽  
Vol 136 (7) ◽  
pp. 1976S-1978S ◽  
Author(s):  
Eleanor Raffan ◽  
Shelley L. Holden ◽  
Fay Cullingham ◽  
Rachel M. Hackett ◽  
John M. Rawlings ◽  
...  

Nutrients ◽  
2010 ◽  
Vol 2 (9) ◽  
pp. 950-964 ◽  
Author(s):  
Frances A. Tylavsky ◽  
Patricia A. Cowan ◽  
Sarah Terrell ◽  
Merschon Hutson ◽  
Pedro Velasquez-Mieyer

2004 ◽  
Vol 56 (1) ◽  
pp. 47-54 ◽  
Author(s):  
Andrea C Buchholz ◽  
Karen M Majchrzak ◽  
Kong Y Chen ◽  
Sadhna M Shankar ◽  
Maciej S Buchowski

Author(s):  
Reham A. Mostafa ◽  
Doaa R. Negm ◽  
Naser A. ElSawy

Background: Dual energy X-ray absorptiometry (DEXA) is the most accurate technique in determining fat percentage but it is unpotable, expensive, unavailable for general applicability. Objective: This study aimed to find the most accurate and easiest technique as alternative to DEXA for quick determination of body fat%. This study examined the accuracy of three models of Bioelectrical impedance analysis (BIA) technique (Fat Loss Monitor- Body Composition -Body Fat Analyzer) in determining the body fat percentage with using DEXA as a reference standard. Subject and Methods: A cross sectional study was carried out during the period from (28-9-2017) to (5-4-2018) among a random sample of (53) volunteers female student in Umm Al Qura University from Faculty of Applied Medical Science aged between (20-39 years) from different level of education. All subjects were generally healthy, data was collected through a structured questionnaire compose of three section. Demographic data was collected and anthropometric measurements were evaluated as well as body composition (Only body fat%) using DEXA, body composition monitor, fat loss monitor and body fat analyzer. Results: BMI classification of the total 53 subjects was including 8 healthy females, 17 overfat, 25 obese and 3 underweight. The fat% result from DEXA and body fat analyzer was significant difference at (P < 0.05). Fat percent result from DEXA and Body Composition device was non-significant difference at (P>0.05). The fat% result from DEXA and Fat Loss Monitor device was significant at difference (P<0.05). Conclusion: The most accurate of BIA technique was the Body Composition device compering to DEXA.