scholarly journals A highly sensitive biosensor based on methacrylated graphene oxide-grafted polyaniline for ascorbic acid determination

2020 ◽  
Vol 9 (1) ◽  
pp. 760-767 ◽  
Author(s):  
Seyed Morteza Naghib ◽  
Farahnaz Behzad ◽  
Mehdi Rahmanian ◽  
Yasser Zare ◽  
Kyong Yop Rhee

AbstractFunctionalized graphene-based nanocomposites have opened new windows to address some challenges for increasing the sensitivity, accuracy and functionality of biosensors. Polyaniline (PANI) is one of the most potentially promising and technologically important conducting polymers, which brings together the electrical features of metals with intriguing properties of plastics including facile processing and controllable chemical and physical properties. PANI/graphene nanocomposites have attracted intense interest in various fields due to unique physicochemical properties including high conductivity, facile preparation and intriguing redox behavior. In this article, a functionalized graphene-grafted nanostructured PANI nanocomposite was applied for determining the ascorbic acid (AA) level. A significant current response was observed after treating the electrode surface with methacrylated graphene oxide (MeGO)/PANI nanocomposite. The amperometric responses showed a robust linear range of 8–5,000 µM and detection limit of 2 µM (N = 5). Excellent sensor selectivity was demonstrated in the presence of electroactive components interfering species, commonly found in real serum samples. This sensor is a promising candidate for rapid and selective determination of AA.

2011 ◽  
Vol 81 (2) ◽  
pp. 104-108 ◽  
Author(s):  
Malledevaru Mallesha ◽  
Revanasiddappa Manjunatha ◽  
C. Nethravathi ◽  
Gurukar Shivappa Suresh ◽  
Michael Rajamathi ◽  
...  

Biosensors ◽  
2020 ◽  
Vol 10 (3) ◽  
pp. 24 ◽  
Author(s):  
Shanshan Wei ◽  
Haolin Xiao ◽  
Liangli Cao ◽  
Zhencheng Chen

In this article, a highly sensitive label-free immunosensor based on a graphene oxide (GO)/Fe3O4/Prussian blue (PB) nanocomposite modified electrode was developed for the determination of human hepatitis B surface antigen (HBsAg). In this electrochemical immunoassay system, PB was used as a redox probe, while GO/Fe3O4/PB nanocomposites and AuNPs were prepared and coated on screen-printed electrodes to enhance the detection sensitivity and to immobilize the hepatitis B surface antibody (HBsAb). The immunosensor was fabricated based on the principle that the decrease in peak currents of PB is proportional to the concentration of HBsAg captured on the modified immunosensor. The experimental results revealed that the immunosensor exhibited a sensitive response to HBsAg in the range of 0.5 pg·mL−1 to 200 ng·mL−1, and with a low detection limit of 0.166 pg·mL−1 (S/N = 3). Furthermore, the proposed immunosensor was used to detect several clinical serum samples with acceptable results, and it also showed good reproducibility, selectivity and stability, which may have a promising potential application in clinical immunoassays.


Sign in / Sign up

Export Citation Format

Share Document