Resonance Broadening and Oscillator strength of the Mercury Absorption Line 1850 Å

1975 ◽  
Vol 30 (4) ◽  
pp. 445-450 ◽  
Author(s):  
D. Gebhard ◽  
W. Behmenburg

Abstract A new method for the determination of f-values of resonance transitions from wing-measurements of selfbroadened resonance absorption lines is described. The method is applied to the mercury resonance transition 61 S0→61P1, λ 1850 Å. The resulting f-value of 1.08±0.05 agrees well with those obtained from other methods.

1999 ◽  
Vol 183 ◽  
pp. 167-167 ◽  
Author(s):  
T. Wiklind ◽  
F. Combes

A potential diagnostic application of molecular rotational absorption lines at high redshift is to test the invariance of physical constants. This can be done by comparing the observed redshifted frequency of a molecular absorption line with redshifted lines from other types of transitions such as the 21cm hyperfine transition or electronic resonance transitions. In order to set stringent limits, it is necessary to achieve the greatest possible frequency resolution. This makes radio lines well suited for this purpose.


Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6286
Author(s):  
Vladimir Liger ◽  
Vladimir Mironenko ◽  
Yury Kuritsyn ◽  
Mikhail Bolshov

A new scheme for a calibration-free diode laser absorption spectroscopy (DLAS) sensor for measuring the parameters of harsh zones is proposed. The key element of the scheme is a micro-prism retroreflector (MPRR). The MPRR facilitates an increase in the mechanical stability of the sensor and a decrease in the background thermal radiation in the hot areas of a tested zone. Reduction in the broadband thermal emission allowed the application of a differential logarithmic conversion (LC) technique for elimination of the residual amplitude modulation and other sources of non-selective attenuation of the probing laser beam. LC allows the use of a 1f-wavelength modulation spectroscopy (WMS) detection scheme. Combination of LC and a 1f-WMS algorithm provided a new modification of calibration-free DLAS, which could be particularly useful for probing harsh zones with pronounced strong turbulence and high levels of acoustic and electrical noise. The influence of the experimental parameters and characteristics of the main electronic components of the recording and processing system on the accuracy of the integral line intensity determination is investigated theoretically and experimentally. The proposed optical scheme of a DLAS sensor and algorithm for the data processing allowed the integral intensity of an absorption line to be obtained. The potential for the scheme was exemplified with a single water vapor absorption line at 7185.6 cm−1. Simultaneous detection of several absorption lines and data processing using the developed algorithm provides the final goal of a DLAS sensor—determination of temperature and partial pressure of a test molecule in a probed gas volume. The developed scheme allows the spatial multiplexing of the radiation of different diode lasers (DLs), which can be used if various test molecules are to be detected, or absorption lines of a test molecule are detected over different wavelength intervals.


1960 ◽  
Vol 23 ◽  
pp. 227-232 ◽  
Author(s):  
P WEST ◽  
G LYLES
Keyword(s):  

1977 ◽  
Vol 37 (02) ◽  
pp. 210-215 ◽  
Author(s):  
R Margalit ◽  
E Gidron ◽  
Y Shalitin

SummaryThe term “effective activator” of plasminogen is proposed, to denote the resultant of activator-antiactivator interaction, and a method for the determination of the level of these activators is described. By adding axcess plasminogen to the euglobulin fraction of plasma the influence of the level of endogenous plasminogen and of the antiplasmin is eliminated. It is shown that the level of fibrinogen has very little bearing on the results. An effective activator unit is defined as equal to 1 CTA unit of urokinase activity on a fibrinogen-plasminogen substrate.


1964 ◽  
Vol 12 (01) ◽  
pp. 119-125 ◽  
Author(s):  
Y Shamash ◽  
A Rimon

SummaryA new method for the assay of plasmin inhibitors in human plasma is described. The method consists of determination of the caseinolytic activity of a standard plasmin solution before and after incubation with the inhibitor, with lysine added to the mixture as a stabilizer of plasmin. Using this method, it was found that plasma contains enough inhibitors to inactivate 30 caseinolytic units of plasmin, or 10 times the normal amount of plasminogen in human plasma.


1969 ◽  
Vol 62 (1_Suppl) ◽  
pp. S95-S112 ◽  
Author(s):  
A. H. W. M. Schuurs

ABSTRACT Various techniques for sensitising erythrocytes and latex particles with gonadotrophins, particularly with HCG, are described. The haemagglutination inhibition reactions are generally interpreted by means of »erythrocyte settling patterns«. By a new method of evaluating these patterns a relatively precise quantitative determination is possible. Latex agglutination inhibition reactions on slides are particularly suitable as rapid qualitative tests. In cases where the maximum attainable sensitivity of the agglutination inhibition tests is insufficient, e. g. for determining LH concentrations in urine, the hormone in the test fluid has to be concentrated or extracted. An alternative method is a modified haemagglutination inhibition test for large volumes which is applicable to unconcentrated urine. Due to non-specific inhibitions the above-mentioned tests cannot be applied to unprocessed serum. Agglutination inhibition tests with HCG are already well advanced, pregnancy diagnosis being their main application. Now that highly purified HCG is available, a satisfactory specificity for these tests can be attained. If the immune system for HCG is used for estimating LH, it has to meet additional specificity requirements. Furthermore, the measure of cross-reaction and the choice of standard merit special attention. Finally, a literature survey is given of test systems in which LH and FSH were used as antigens.


2017 ◽  
Vol 68 (4) ◽  
pp. 671-674
Author(s):  
Ana Maria Galan ◽  
Ioan Calinescu ◽  
Elena Radu ◽  
Elena Emilia Oprescu ◽  
Gabriel Vasilievici ◽  
...  

The purpose of this study was to develop a method for rapid quantitative and qualitative determination of the oil from microalgae lipid fraction obtained from Nannochloris sp biomass. The lipid fraction was first refluxed with 4% KOH in MeOH (60, 90, 120 min), followed by reaction with 20% BF3 in MeOH, using different times of reflux (90,120, 150 min) for each time of reflux with 4% KOH in MeOH. The FAME samples were analyzed by GC-MS analysis. 120 min reflux with 4% KOH in MeOH, 90 min with 20% BF3 in MeOH and a ratio lipid fraction: 4% KOH in MeOH: 20% BF3 in MeOH=1:20:27, were required to obtain the higher percent of oil in the microalgae lipid fraction. The relevance of the method developed was proved by TGA analysis and by transesterification of a sunflower oil sample in the same conditions.


2018 ◽  
pp. 76-84
Author(s):  
K. V. Sorokin ◽  
E. A. Sunarchina

Improvement of orbits precision is one of the most important tasks of space surveillance catalogue maintenance. The solution of this problem is directly related to an adequate consideration of the errors of the coordinate information from the measuring instruments. The article consideresd a new method for estimating the precision of measuring instruments on the catalog orbits. To carry out such analysis, in PJSC «VIMPEL» special technological program was created. Main results of a study of radar errors with orbits of space surveillance catalogue was presented. Also, the results were compared with data of measuring instrument's calibration software complex. This software complex provides determination of satellite's position with errors less than 10 m. A new dynamic model of measuring instrument errors is proposed.


Sign in / Sign up

Export Citation Format

Share Document