scholarly journals Advanced Fiber-Coupled Diode Laser Sensor for Calibration-Free 1f-WMS Determination of an Absorption Line Intensity

Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6286
Author(s):  
Vladimir Liger ◽  
Vladimir Mironenko ◽  
Yury Kuritsyn ◽  
Mikhail Bolshov

A new scheme for a calibration-free diode laser absorption spectroscopy (DLAS) sensor for measuring the parameters of harsh zones is proposed. The key element of the scheme is a micro-prism retroreflector (MPRR). The MPRR facilitates an increase in the mechanical stability of the sensor and a decrease in the background thermal radiation in the hot areas of a tested zone. Reduction in the broadband thermal emission allowed the application of a differential logarithmic conversion (LC) technique for elimination of the residual amplitude modulation and other sources of non-selective attenuation of the probing laser beam. LC allows the use of a 1f-wavelength modulation spectroscopy (WMS) detection scheme. Combination of LC and a 1f-WMS algorithm provided a new modification of calibration-free DLAS, which could be particularly useful for probing harsh zones with pronounced strong turbulence and high levels of acoustic and electrical noise. The influence of the experimental parameters and characteristics of the main electronic components of the recording and processing system on the accuracy of the integral line intensity determination is investigated theoretically and experimentally. The proposed optical scheme of a DLAS sensor and algorithm for the data processing allowed the integral intensity of an absorption line to be obtained. The potential for the scheme was exemplified with a single water vapor absorption line at 7185.6 cm−1. Simultaneous detection of several absorption lines and data processing using the developed algorithm provides the final goal of a DLAS sensor—determination of temperature and partial pressure of a test molecule in a probed gas volume. The developed scheme allows the spatial multiplexing of the radiation of different diode lasers (DLs), which can be used if various test molecules are to be detected, or absorption lines of a test molecule are detected over different wavelength intervals.

2009 ◽  
Vol 10 (9) ◽  
pp. 907-915 ◽  
Author(s):  
Koichi M.T. Yamada ◽  
Atsushi Onae ◽  
Feng-Lei Hong ◽  
Hajime Inaba ◽  
Tadao Shimizu

1975 ◽  
Vol 30 (4) ◽  
pp. 445-450 ◽  
Author(s):  
D. Gebhard ◽  
W. Behmenburg

Abstract A new method for the determination of f-values of resonance transitions from wing-measurements of selfbroadened resonance absorption lines is described. The method is applied to the mercury resonance transition 61 S0→61P1, λ 1850 Å. The resulting f-value of 1.08±0.05 agrees well with those obtained from other methods.


2012 ◽  
Vol 38 (4) ◽  
pp. 123-129 ◽  
Author(s):  
Māris Abele ◽  
Jānis Balodis ◽  
Inese Janpaule ◽  
Ieva Lasmane ◽  
Augusts Rubans ◽  
...  

Recent accomplishments in advancement of accurate astrometric reference star catalogues, development of digital imaging technology, high accuracy tiltmeter technology, and geocentric coordinate availability provided by GNSS, have made possible accurate, fast and automated determination of vertical deflections using astrometric methods. Zenith cameras for this kind of measurements have been developed or are being developed by several research groups. The paper describes a research project by Institute of Geodesy and Geoinformation, intended to design a portable digital zenith camera for vertical deflection determination with 0.1” expected accuracy. Camera components are described, proposed data processing algorithm and preliminary results, obtained with prototype instrument, are presented.


2021 ◽  
pp. 464-468
Author(s):  
A.D. Tikhonov ◽  
A.A. Kochiev

The article deals with determination of coordinates using global navigation systems, and application of the PPP data processing algorithm to obtain coordinates. The authors conducted an experiment illustrating the algorithm accuracy.


Sign in / Sign up

Export Citation Format

Share Document